Installation Manual Part 5
Table Of Contents
PRELIMINARY
D-1
BWX 8415 Basestation Installation and Commissioning Guide
OL-19519-01
APPENDIX
D
RF Center Frequency and Interference Analysis
Guidelines
Reference: RF Center Frequency and Interference Analysis
These guidelines are intended for an experienced and Cisco qualified specialist Field Engineer to gather
data for RF Engineering purposes. The procedures that are described are performed in order to make a
determination of basestation center frequency and possible interference points. Please refer to all
regulatory information for your region prior to performing these procedures.
Before You Start
Overview
An RF interference analysis is usually called for under two conditions. One is when it is used for
evaluating a candidate BWX 8415 Basestation (BS) site prior to deployment of equipment. We refer to
the interference testing under these circumstances as a Pre-installation Test. The second is the
Post-installation Test, when data is collected to determine (a) if there is any interference in the area at
all; or (b) the source, or cause, of known interference in the area of the installed and operational site. As
is obvious from the name of this test, it occurs after the basestation has been deployed and turned up.
The instructions in this document assume the Field Engineer is at the BS site where the testing will take
place. The data the Field Engineer gathers using the Interference Sweep procedure in this document will
be evaluated and used in the calibration of the basestation. The data will help verify and plan for noise
in the area.
To get the most benefit from this procedure, we suggest you follow these high-level steps:
Step 1: Read the entire procedure.
Step 2: Choose the correct Test configuration setup, per this procedure.
Step 3: Perform the Interference Sweep procedure.
Step 4: Send the results to Cisco or your RF Engineer.