User's Manual

Navini Networks, Inc. Ripwave Base Station I&C Guide
139
Center Frequency: Set to frequency to be tested
Span: 10 MHz
Resolution Bandwidth: 100 KHz
Video Bandwidth: 100 KHz
Sweep Time: Auto
Signal Generator - connected to the RFS cable end
Frequency: Set to frequency to be tested
Signal Level: 0 dB
Equipment Calibration
Refer to Figure K14 to calibrate the test equipment.
Perform “Equipment Set-Up”.
Connect the test cable from the “RF Output” of the Signal Generator to the
“RF input” of the Spectrum Analyzer.
Turn on the RF output of the Signal Generator.
Perform a “peak search” on the Spectrum Analyzer.
Set a Delta point. The Delta sets a zero point on the Spectrum Analyzer so that
when any additional cable or equipment is added to the link the new loss
reading can be recorded. (Note: If the Spectrum Analyzer does not have a
Delta function, increase the output of the Signal Generator until there is a 0
dB reading on the Spectrum Analyzer.)
Figure K14: Calibrate Test Equipment
Amplitude: 0 dBm
Signal Generator
Spectrum Analyzer
Barrel
Connector
Amplitude: 0 dBm
Signal Generator
Spectrum Analyzer
Barrel
Connector