User's Manual

Navini Networks, Inc. Ripwave Base Station I&C Guide
126
2.3 GHz (High band)
2348.25 2352.50 2360.00
2.4 GHz
2400.00 2440.00 2473.50
2.5 GHz
2500.00 2548.00 2596.00
2.6 GHz
2596.00 2641.00 2686.00
3.4 GHz
3410.00 3462.50 3525.00
3.5 GHz
3500.00 3550.00 3600.00
1. Connect the Signal Generator cable to the Signal Generator.
2. Connect the Spectrum Analyzer cable to the Spectrum Analyzer.
3. Connect the other end of the two cables together. Use a barrel connector if needed.
Figure K2: Test Setup
Test Procedure
The following procedures are for the Agilent E4402B Spectrum Analyzer. If alternative
equipment is used, refer to the manufacturer’s calibration procedures. The key point is to make
accurate microwave frequency power measurements.
Step 1. Turn the Signal Generator and Spectrum Analyzer on. Allow the equipment to warm
up for 15 minutes for the output to stabilize.
Step 2. Set the Signal Generator frequency to the desired test frequency (Table K4) of the RFS
under test.
Signal
Generator
Spectrum
Analyzer
Barrel connector
Signal
Generator
Spectrum
Analyzer
Barrel connector