User's Manual
Table Of Contents
3
Power Considerations
Installation of your small cell module requires an additional
6 watts to power the Cisco Aironet 3600 access point. With a
USC 5310 module installed, the access point requires the full
Power over Ethernet Plus (PoE+) of 25.5 Watts at the egress
switch port and a cable run of less than 300 feet (100 meters).
Power options for the access point include:
• IEEE 802.3at POE+ 25.5 W delivered from the upstream
Ethernet switch
• Cisco 3600 Series Power Injector (AIR-PWRINJ4=)
• Cisco 3600 Series local power supply (AIR-PWR-B=)
The USC 5310 module has a power limit circuitry that shuts
down the module if it draws more power than allowed.
Installation Considerations
Install your small cell:
• in a central location, in an area where people are most likely
to make calls
• away from windows, to avoid the signal leaking outside or
external signals leaking in
• in an open area with airflow; not in a closed cabinet which
reduces the signal strength
If you have thick internal walls, or metal, fire or rotating doors,
plan to place units at either side of the obstruction at a distance
shorter than 49 feet (15 m). Install a unit across from a corner
to provide coverage on both sides of the corner.
For more information, refer to the “Cisco Aironet AP Module
for Wireless Security and Spectrum Intellgence (WSSI)
Deployment Guide” at the following URL:
http://www.cisco.com/en/US/products/ps11983/
products_tech_note09186a0080bed15d.shtml.