A P P E N D I X D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards This appendix provides information on the cards supported in CTM. This appendix contains the following sections: Note Caution • D.1 FC_MR-4 Card, page D-1 • D.2 FMEC Cards, page D-7 • D.3 Multirate Cards, page D-17 • D.4 Optical Cards, page D-66 • D.5 Transponder Cards, page D-213 In the CTM GUI, read-only fields have a gray background.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FC_MR-4 Card • Two contiguously concatenated (CCAT) STS-24c/VC4-8c circuits • One STS-48c/VC4-16c CCAT • Two virtually concatenated (VCAT) circuits (STC3c-8V/VC4-8v) compliant with ITU-T G.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FC_MR-4 Card Table D-1 Field Descriptions for the Identification Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FC_MR-4 Card D.1.1.4 Port Tab The Port tab allows you to view and update FC_MR port information. The tab contains the following subtabs: • D.1.1.4.1 General Subtab, page D-4 • D.1.1.4.2 Distance Extension Subtab, page D-4 • D.1.1.4.3 Enhanced FC/FICON Subtab, page D-5 D.1.1.4.1 General Subtab The General subtab allows you to view and update general port information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FC_MR-4 Card Table D-4 Field Descriptions for the Distance Extension Subtab Field Description Port No. Displays the port number. Enable Distance Extension Check to enable end-to-end distances of up to 1600 km for 1 GFC and up to 800 km for 2 GFC. When enabled, all the fields for the port are enabled. Auto Detect Credits Check to enable automatic detection of buffer credits for flow control.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FC_MR-4 Card Table D-7 Field Descriptions for the RMON Thresholds Tab Field Description Index Number A unique value that identifies the different thresholds currently existing on the NE. Slot Select a slot for the new FC_MR threshold. Port Select a port for the selected slot. If you select All, the threshold will be created on all ports for that slot. This operation may take several minutes to complete.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards Table D-9 Field Descriptions for the GBIC Inventory Tab Field Description Port Number Displays the GBIC card port number. Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot. Values are single mode or multimode. Hardware Part Number Displays the manufacturer's part number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards D.2.1 Slot Properties—FMEC-DS-1/E1 The Slot Properties pane displays information about the Cisco ONS 15454 SDH slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds. The ONS 15454 SDH FMEC-DS-1/E1 card provides front-mount electrical connection for 14 ITU-compliant, G.703 E-1 ports.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards The ONS 15454 SDH FMEC-DS-3/E3 card provides front-mount electrical connection for 14 ITU-compliant, G.703 E-1 ports. With the FMEC-DS-3/E3 card, each E1-N-14 port operates at 2.048 Mbps over a 120-ohm, balanced cable through two 37-pin DB connectors. For the FMEC DS-3/E3 module, the Slot Properties pane displays the following tabs: Module View and Identification. D.2.2.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards The ONS 15454 SDH FMEC-E1 card provides front-mount electrical connection for fourteen ITU-compliant, G.703 E-1 ports. With the FMEC-E1 card, each E1-N-14 port operates at 2.048 Mbps over a 75-ohm unbalanced coaxial 1.0/2.3 miniature coaxial connector. For the FMEC-E1 module, the Slot Properties pane displays the following tabs: Module View, Identification, and Info. D.2.3.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.2.4 Slot Properties—FMEC-E1-120NP The Slot Properties pane displays information about the Cisco ONS 15454 SDH slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards Table D-15 Field Descriptions for the Identification Tab (continued) Field Description Product ID Displays a product ID string of 63 characters maximum. If the card does not support the product ID, the field shows N/A. Version ID Displays a version ID string in the format “V99_.” The version ID always begins with a V and ends with a space.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards D.2.5.2 Identification Tab The Identification tab allows you to view and update the FMEC-STM1E 1:1 card identification information. Table D-17 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards Table D-17 Field Descriptions for the Identification Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards D.2.6 Slot Properties—MIC-A/P The Slot Properties pane displays information about the Cisco ONS 15454 SDH slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds. The MIC-A/P card provides connection for the BATTERY B input, one of the two possible redundant power supply inputs.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards FMEC Cards D.2.7 Slot Properties—MIC-C/T/P The Slot Properties pane displays information about the Cisco ONS 15454 SDH slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds. The MIC-C/T/P card provides connection for the BATTERY A input, one of the two possible redundant power supply inputs.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3 Multirate Cards This section describes the following multirate cards supported within CTM: • D.3.1 Slot Properties—ASAP_4, page D-17 • D.3.2 Slot Properties—MRC-12, page D-38 D.3.1 Slot Properties—ASAP_4 The Slot Properties pane displays information about the Cisco ONS 15600 SONET slot that is selected in the NE Explorer tree.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-21 Field Descriptions for the Card Identification Tab Field Description Equipment Type Displays the equipment type that the slot is provisioned for. Hardware Part Number Displays the card part number that is printed on the top of the card. Hardware Revision Displays the hardware revision number. Serial Number Displays the card serial number that is unique to each card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-21 Field Descriptions for the Card Identification Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-22 Field Descriptions for the Pluggable Provisioning Tab (continued) Field Description Actual Equipment Type Displays the actual pluggable I/O module that is installed in the pluggable slot. Firmware Version Displays the revision number of the software used by the ASIC chip installed on the pluggable I/O module.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-22 Field Descriptions for the Pluggable Provisioning Tab (continued) Field Description Equipment Type Displays the equipment type that the pluggable slot is provisioned for. Hardware Part Number Displays the card part number that is printed on the top of the card. Hardware Revision Displays the hardware revision number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.1.4 Line Tab The Line tab allows you to view and update optical line performance monitoring information. The Line tab contains the following subtabs: • D.3.1.4.1 Line Config Subtab, page D-22 • D.3.1.4.2 Line Thresh 15 Min Subtab, page D-24 • D.3.1.4.3 Line Thresh 1 Day Subtab, page D-25 • D.3.1.4.4 Physical Thresh 15 Min Subtab, page D-26 • D.3.1.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-23 Field Descriptions for the Line Config Subtab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-23 Field Descriptions for the Line Config Subtab (continued) Field Description Reach Allows you to provision the reach value. You can choose Auto Provision, which allows the system to automatically provision the reach from the PPM reach value on the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-24 Field Field Descriptions for the Line Thresh 15 Min Subtab Description Near End Port Number Displays the optical port number CV-L Displays the coding violations–line ES-L Displays the errored seconds–line SES-L Displays the severely errored seconds–line UAS-L Displays the unavailable seconds–line FC-L Displays the failure count–line PSC Displays the protection switchin
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-25 Field Descriptions for the Line Thresh 1 Day Subtab (continued) Field Description PSC Displays the protection switching count–line PSD Displays the protection switching duration–line PSC-W Displays the protection switching count–working PSD-W Displays the protection switching duration–working PSC-S Displays the protection switching count–span PSD-S Displays the protectio
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-27 Field Field Descriptions for the Physical Thresh 1 Day Subtab Description Near End Port Number Displays the port number. LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent. LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent. OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.1.4.8 Alarm Thresh Subtab The Alarm Thresh subtab allows you to select the thresholds for the alarms. Table D-30 Field Descriptions for the Alarm Thresh Subtab Field Description Port No. Port number. LBC-HIGH Laser bias current maximum. LBC-LOW Laser bias current minimum. OPT-HIGH Optical power transmitted maximum. OPT-LOW Optical power transmitted minimum.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-32 Field Field Descriptions for the Path Thresh 15 Min Subtab Description Near End STS Number Displays the synchronous transport signal number information. CV-P Displays coding violations–path information. ES-P Displays errored seconds–path information. SES-P Displays severely errored seconds–path information. UAS-P Displays unavailable seconds–path information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-33 Field Descriptions for the Path Thresh 1 Day Subtab (continued) Field Description Far End STS No Displays the synchronous transport signal number information. CV-P Displays coding violations–path information. ES-P Displays errored seconds–path information. FC-P Displays failure count–path information. SES-P Displays severely errored seconds–path information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-35 Field Descriptions for the Loopback Tab (continued) Field Description Administration State The port administration state. It can be: Service State • IS—In Service. • IS, AINS—Automatic In Service. • OOS, DSBLD—Out of Service, Disabled. • OOS, MT—Out of Service, Maintenance. Overall availability of the entity. Values are: • IS_NR—In Service–Normal.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-37 Field Descriptions for the Alarm Behavior Tab Field Description Port Number Displays the card port number. Alarm Profile Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a customized alarm profile. Suppress Alarms If checked, all alarms are suppressed for the port. Alarm Profile Choose an alarm profile for all ports.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-40 Field Descriptions for the Ether Line Tab (continued) Field Description Admin State The port administration state. It can be: Service State • IS—In Service. • IS, AINS—Automatic In Service. • OOS, DSBLD—Out of Service, Disabled. • OOS, MT—Out of Service, Maintenance. Overall availability of the entity. Values are: • IS_NR—In Service–Normal.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-40 Field Descriptions for the Ether Line Tab (continued) Field Description Reach Allows you to provision the reach value. You can choose Auto Provision, which allows the system to automatically provision the reach from the PPM reach value on the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.1.12.1 Ether Loopback Port Subtab The Ether Loopback Port subtab allows you to configure Ethernet loopback port information. Table D-41 Field Descriptions for the Ether Loopback Port Subtab Field Description Port Number The port number. Loopback Type Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current loopback (none).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-42 Field Descriptions for the SONET STS (Ether) Subtab Field Description STS Displays the STS number XC Loopback Displays the cross-connect loopback status. D.3.1.13 Alarm Behavior Tab The Alarm Behavior tab contains the following subtabs: • D.3.1.13.1 Ether Alarm Behavior Subtab, page D-36 • D.3.1.13.2 POS Alarm Behavior Subtab, page D-36 D.3.1.13.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-45 Field Descriptions for the POS Line Tab Field Description Port Number Displays the card port number. Port Name Allows you to enter a port name. Admin State The port administration state. It can be: Service State • IS—In Service. • IS, AINS—Automatic In Service. • OOS, DSBLD—Out of Service, Disabled. • OOS, MT—Out of Service, Maintenance.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-46 Field Descriptions for the Transceiver Tab Field Description Port No. PIM number, PPM number, Port number. Non-normalized LBC (mA) The actual operating value of laser bias current (in mA) for the specified card port. Non-normalized OPT (dBm) The actual operating value of optical power transmitted (in dBm) for the specified card port.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards The maximum bandwidth of the MRC-12 card is determined by the cross-connect card, as shown in the following table.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards – If port 7 is used as an OC-12/STM-4, Ports 5, 6, and 8 are disabled. – If port 10 is used as an OC-12/STM-4, Ports 9, 11, and 12 are disabled. – Any port can be used as an OC-3/STM-1 as long as all of the above rules are followed. • STS-192 – Ports 1, 4, 7, and 10 are the only ports usable as OC-48/STM-16. – If port 4 is used as an OC-48/STM-16, Ports 2 and 3 are disabled.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-49 Field Descriptions for the Identification Tab (continued) Field Description Hardware Revision Displays the hardware revision number. Serial Number Displays the card serial number that is unique to each card. CLEI Code Displays the CLEI code. Firmware Version Displays the revision number of the software used by the ASIC chip installed on the card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.2.3 Pluggable Provisioning Tab The Pluggable Provisioning tab allows you to view and provision pluggable entities; for example, pluggable port module (PPM) and the ports inside these entities. Table D-50 Field Descriptions for the Pluggable Provisioning Tab Field Description Pluggable Port Modules Pluggable Number Displays the identifier of the plugin module.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.2.3.1 Provision Pluggable Dialog Box Click the Create button to launch the Provision Pluggable dialog box. The Provision Pluggable dialog box allows you to provision pluggable entities; for example, the PPM and PIM, and to create the ports inside these entities. See C.1.7.5.1 Provision Pluggable Dialog Box, page C-37 for more information. D.3.2.3.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-51 Field Descriptions for the Line Config Subtab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-51 Field Descriptions for the Line Config Subtab (continued) Field Description Admin SSM If the node does not receive an SSM signal, it defaults to STU (synchronization traceability unknown).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-51 Field Descriptions for the Line Config Subtab (continued) Field Description Reach Allows you to provision the reach value. You can choose Auto Provision, which allows the system to automatically provision the reach from the PPM reach value on the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-52 Field Descriptions for the Line Thresh 15 Min Subtab (continued) Field Description ES-L Displays the errored seconds–line SES-L Displays the severely errored seconds–line CV-L Displays the coding violations–line UAS-L Displays the unavailable seconds–line FC-L Displays the failure count–line PSC Protection switching count–line PSD Protection switching duration–line PSC
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-53 Field Descriptions for the Line Thresh 1 Day Subtab (continued) Field Description PSC-W Protection switching count–working PSD-W Protection switching duration–working PSC-S Protection switching count–span PSD-S Protection switching duration–span PSC-R Protection switching count–ring PSD-R Protection switching duration–ring Far End Port Number Displays the optical port
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-55 Field Field Descriptions for the Physical Thresh 1 Day Subtab Description Near End Port Number Displays the port number. LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent. LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent. OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.2.4.8 Alarm Thresholds Subtab The Alarm Thresholds subtab allows you to select the thresholds for the alarms. Table D-58 Field Descriptions for the Alarm Thresholds Subtab Field Description Port No. Port number. LBC-HIGH Laser bias current maximum. LBC-LOW Laser bias current minimum. OPT-HIGH Optical power transmitted maximum. OPT-LOW Optical power transmitted minimum.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-59 Field Descriptions for the Line Config Subtab (continued) Field Description Admin State The port administration state. It can be: • IS—In Service. • IS, AINS—Automatic In Service. • OOS, DSBLD—Out of Service, Disabled. • OOS, MT—Out of Service, Maintenance. Port Rate Sets the rate of the new port. Service State Overall availability of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-59 Field Descriptions for the Line Config Subtab (continued) Field Description AINS Soak Count Down (H:M) Automatic in-service soak countdown. Displays the remaining time of valid input signal in hh:mm, after which the card becomes in service (IS) automatically. Admin SSM If the node does not receive an SSM signal, it defaults to STU (synchronization traceability unknown).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-59 Field Descriptions for the Line Config Subtab (continued) Field Description Reach Allows you to provision the reach value. You can choose Auto Provision, which allows the system to automatically provision the reach from the PPM reach value on the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-60 Field Descriptions for the MS Thresh 15 Min Subtab (continued) Field Description EB-MS Displays the errored block–multiplex section BBE-MS Displays the background block errors–multiplex section ES-MS Displays the errored seconds–multiplex section SES-MS Displays the severely errored seconds–multiplex section UAS-MS Displays the unavailable seconds–multiplex section PSC D
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-61 Field Descriptions for the MS Thresh 1 Day Subtab (continued) Field Description PSC-W Displays the protection switching count–working PSD-W Displays the protection switching duration–working PSC-S Displays the protection switching count–span PSD-S Displays the protection switching duration–span PSC-R Displays the protection switching count–ring PSD-R Displays the protecti
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-63 Field Field Descriptions for the Physical Thresh 1 Day Subtab Description Near End Port Number Displays the port number. LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent. LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent. OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-65 Field Descriptions for the RS Thresh 1 Day Subtab (continued) Field Description ES-RS Displays the errored seconds–regenerator section SES-RS Displays the severely errored seconds–regenerator section UAS-RS Displays the unavailable seconds–regenerator section OFS-RS Displays the out of framing seconds–regenerator section D.3.2.5.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.2.6.2 Path Thresh 15 Min Subtab The Path Thresh 15 Min subtab allows you to view and change the 15-minute path thresholds of the MRC-12 card. Table D-68 Field Descriptions for the Path Thresh 15 Min Subtab Field Description Near End STS Number Displays the synchronous transport signal number information. CV-P Displays coding violations–path information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-69 Field Descriptions for the Path Thresh 1 Day Subtab (continued) Field Description SES-P Displays severely errored seconds–path information. UAS-P Displays unavailable seconds–path information. FC-P Displays failure count–path information. PPJC-Pdet Displays positive pointer justification count, STS path detected.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.2.7.1 VC-4 Config Subtab The VC-4 Config subtab allows you to view and change the VC-4 settings of the MRC-12 card. Table D-71 Field Descriptions for the VC-4 Config Subtab Field Description VC Number Displays the VC number. IPPM Enabled Check to enable intermediate path performance monitoring (IPPM) and uncheck to disable IPPM. XC Loopback Indicates cross-connect loopback. D.3.2.7.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-72 Field Descriptions for the SDH Path Thresh 15 Min Subtab (continued) Field Description UAS-HP Unavailable seconds–higher order path. BBE-HP Background block errors–higher order path. D.3.2.7.3 SDH Path Thresh 1 Day Subtab The SDH Path Thresh 1 Day subtab allows you to view and change the 1-day path thresholds of the MRC-12 card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards D.3.2.7.4 Customer Info Subtab The Customer Info subtab allows you to view the customer information. Table D-74 Field Descriptions for the Customer Info Subtab Field Description VC No. The VC number. Customer ID The user-defined customer ID number. Service ID The user-defined service ID number. D.3.2.8 Loopback Tab The Loopback tab allows you to view and update loopback information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-75 Field Descriptions for the Loopback Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-77 Field Descriptions for the Alarm Behavior Tab Field Description Port Number Displays the card port number. Alarm Profile Choose an alarm profile for the port from the drop-down list. Values are Default, Inherited, or a customized alarm profile. Suppress Alarms If checked, all alarms are suppressed for the port. Alarm Profile Choose an alarm profile for all ports.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Multirate Cards Table D-80 Field Descriptions for the Section Trace Subtab Field Description Port Number Displays the port number. Trace Mode The trace mode (Off/None or Manual). Disable AIS/RDI on TIM-S Allows you to disable the Alarm Indication Signal (AIS) and the Remote Defect Indication (RDI) when the path Trace Identifier Mismatch Section (TIM-S) alarm is detected.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4 Optical Cards This section describes the following optical cards supported within CTM: • D.4.1 Slot Properties—OC12 IR/STM4 SH 1310, page D-66 • D.4.2 Slot Properties—OC12-4 IR/STM4 SH 1310, page D-75 • D.4.3 Slot Properties—OC192 LR/STM64 LH 1550, page D-85 • D.4.4 Slot Properties—OC192/STM64 XFR-Based, page D-93 • D.4.5 Slot Properties—OC3 IR 4 1310, page D-113 • D.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.1.1 Module View Tab The Module View tab displays a graphic of the OC12 IR/STM4 SH 1310 that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Alarms are also displayed when you move the mouse pointer over the graphic.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-83 Field Descriptions for the Identification Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-84 Field Descriptions for the Line Tab (continued) Field Description PJSTSMon# Sets the STS that will be used for pointer justification. If set to 0, no STS is monitored. Only one STS can be monitored on each OC-N port.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-84 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-84 Field Descriptions for the Line Tab (continued) Field Description Port Number The optical port number ES-L Errored seconds–line SES-L Severely errored seconds–line CV-L Coding violations–line UAS-L Unavailable seconds–line FC-L Failure count–line Line Threshold 1 Day Near End Port Number The optical port number ES-L Errored seconds–line SES-L Severely errored seconds
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-84 Field Descriptions for the Line Tab (continued) Field Description SES-S Severely errored seconds–section SEFS-S Severely errored framing seconds–section D.4.1.4 STS Tab The STS tab allows you to view and update OC12 IR/STM4 SH 1310 synchronous transport signal (STS) information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-85 Field Descriptions for the STS Tab (continued) Field Description NPJC-Pgen Negative pointer justification count, STS path generated PJCS-Pdet Positive pointer justification count, STS path detected PJCS-Pgen Positive pointer justification count, STS path generated PJC-Diff The sum of the absolute values of differences between positive transmitted and received, and negative tran
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-86 Field Descriptions for the Loopback Tab (continued) Field Description Loopback Type Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current loopback (None). The line state must be OOS_MT before you can configure the loopback type. Note Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-88 Field Descriptions for the Alarm Behavior Tab Field Description Alarm Profile Displays the alarm profile that has been configured for the card. Suppress Alarms If checked, indicates that all alarms are suppressed for the card. Port Number Displays the card port number. Alarm Profile Choose an alarm profile for the port from the drop-down list.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.2.1 Module View Tab The Module View tab displays a graphic of the OC12-4 IR/STM4 SH 1310 that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Alarms also display when you move the mouse pointer over the graphic.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-90 Field Descriptions for the Identification Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-91 Field Descriptions for the Line Tab (continued) PJSTSMon# Sets the STS that will be used for pointer justification. If set to 0, no STS is monitored. Only one STS can be monitored on each OC-N port. • 0 (Cisco default) - 3 (OC3, per port) • 0 (Cisco default) - 12 (OC-12) • 0 (Cisco default) - 48 (OC-48) ProvidesSync If checked, the card is provisioned as an NE timing reference.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-91 Field Descriptions for the Line Tab (continued) Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-91 Field Descriptions for the Line Tab (continued) FC-L Failure count–line PSC Protection switching count PSD Protection switching duration PSC-W Protection switching count–working PSD-W Protection switching duration–working PSC-S Protection switching count–span PSD-S Protection switching duration–span Far End Port Number The optical port number ES-L Errored seconds–line
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-91 Field Descriptions for the Line Tab (continued) CV-S Coding violations ES-S Errored seconds SES-S Severely errored seconds SEFS-S Severely errored framing seconds Section Threshold 1 Day Port Number Displays the optical port number. CV-S Coding violations ES-S Errored seconds SES-S Severely errored seconds SEFS-S Severely errored framing seconds D.4.2.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-92 Field Descriptions for the STS Tab (continued) Field Description SES-P Severely errored seconds–path UAS-P Unavailable seconds–path FC-P Failure count–path PPJC-Pdet Positive pointer justification count, STS path detected NPJC-Pdet Negative pointer justification count, STS path detected PPJC-Pgen Positive pointer justification count, STS path generated NPJC-Pgen Negative
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-93 Field Descriptions for the Loopback Tab (continued) Field Description Loopback Type Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current loopback (None). The line state must be OOS_MT before you can configure the loopback type. Note Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-95 Field Descriptions for the Alarm Behavior Tab Field Description Alarm Profile Displays the alarm profile that has been configured for the card. Suppress Alarms If checked, indicates that all alarms are suppressed for the card. Port Number Displays the card port number. Alarm Profile Choose an alarm profile for the port from the drop-down list.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-97 Field Descriptions for the Info Tab Field Description Extended Manufacturing Information Attribute Displays the nominal card specification. Value Displays the value of the attribute. Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-98 Field Descriptions for the Identification Tab (continued) Field Description Hardware Revision Displays the hardware revision number of the card. Serial Number Displays the card serial number that is unique to each card. CLEI Code Displays the CLEI code. Firmware Version Displays the revision number of the software used by the ASIC chip installed on the card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-98 Field Descriptions for the Identification Tab (continued) Field Description Equipment State Displays the equipment state of the card. Alarm Profile Sets the alarm profile for the port. Check the Suppress Alarms check box to suppress all alarms for this card and its port(s). D.4.3.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-99 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-99 Field Descriptions for the Line Tab (continued) Field Description PSD-S Protection switching duration—span PSC-R Protection switching count—ring PSD-R Protection switching duration—ring Line Threshold 1 Day Port Number The optical port number ES-L Errored seconds–line SES-L Severely errored seconds–line CV-L Coding violations–line UAS-L Unavailable seconds–line FC-L
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-100 Field Descriptions for the STS Tab Field Description STS Config Displays the STS number, the intermediate path protection monitoring (IPPM) status, and XC loopback status.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-100 Field Descriptions for the STS Tab (continued) Field Description Customer ID The user-defined customer ID number Service ID The user-defined service ID number D.4.3.5 Loopback Tab The Loopback tab allows you to view and update OC192 LR/STM64 LH 1550 loopback information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-103 Field Descriptions for the Alarm Behavior Tab (continued) Field Description Alarm Profile Choose an alarm profile for all ports. Force to All Ports When clicked, forces all the ports to the selected alarm profile. D.4.3.8 Auto Laser Shutdown Tab The Auto Laser Shutdown tab allows you to view and update OC192 LR/STM64 LH 1550 ALS parameters.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.4.4 Slot Properties—OC192/STM64 XFR-Based The Slot Properties pane displays information about the Cisco ONS 15454 SONET and ONS 15454 SDH slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-106 Field Descriptions for the Identification Tab (continued) Field Description Administration State The port administration state. It can be: Service State • IS—In Service. • IS, AINS—Automatic In Service. • OOS, DSBLD—Out of Service, Disabled. • OOS, MT—Out of Service, Maintenance. Overall availability of the entity. Values are: • IS_NR—In Service–Normal.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-107 Field Descriptions for the Pluggable Provisioning Tab (continued) Field Description Admin State Select the designation that drives whether an entity is in service or out of service. The Admin state is the driver for the Service state. Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-108 Field Descriptions for the Line Tab Field Description Line Config Port Number Displays the optical port number. Port Name Allows you to enter the name of the optical port. Admin State Displays the status of the line. The line can be In Service (IS), In Service–Auto In Service Soak (IS_AINS), Out of Service (OOS), or Out of Service–Maintenance (OOS_MT).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-108 Field Descriptions for the Line Tab (continued) Field Description Admin SSM If the node does not receive an SSM signal, it defaults to STU (synchronization traceability unknown).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-108 Field Descriptions for the Line Tab (continued) Field Description Reach Allows you to provision the reach value. You can choose Auto Provision, which allows the system to automatically provision the reach from the PPM reach value on the hardware. Choose one of the following reach distances: The reach distances options that appear in the drop-down list depend on the card selected.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-108 Field Descriptions for the Line Tab (continued) Field Description PSC-W Protection switching count–working PSD-W Protection switching duration–working PSC-S Protection switching count–span PSD-S Protection switching duration–span PSC-R Protection switching count–ring PSD-R Protection switching duration–ring Far End Port Number The optical port number ES-L Errored seco
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-108 Field Descriptions for the Line Tab (continued) Field Description Physical Thresh 15 Minutes Port No. Port number. LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent. LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent. OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-108 Field Descriptions for the Line Tab (continued) Field Description LBC-LOW Laser bias current minimum. OPT-HIGH Optical power transmitted maximum. OPT-LOW Optical power transmitted minimum. OPR-HIGH Optical power received maximum. OPR-LOW Optical power received minimum. Set OPR Setting the optical power received (OPR) establishes the received power level as 100 percent.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-109 Field Descriptions for the Line Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-109 Field Descriptions for the Line Tab (continued) Field Description Admin SSM If the node does not receive an SSM signal, it defaults to STU (synchronization traceability unknown).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-109 Field Descriptions for the Line Tab (continued) Field Description Reach Allows you to provision the reach value. You can choose to automatically provision the PPM reach value on the hardware (Auto Provision) or one of the following reach distances: The reach distances that appear in the drop-down list depend on the card selected.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-109 Field Descriptions for the Line Tab (continued) Field Description PSD-W Protection switching duration–working PSC-S Protection switching count–span PSD-S Protection switching duration–span PSC-R Protection switching count–ring PSD-R Protection switching duration–ring Far End Port Number The port number EB-MS Errored block–multiplex section BBE-MS Background block erro
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-109 Field Descriptions for the Line Tab (continued) Field Description LBC-HIGH Laser bias current maximum. Cisco default is (15 min): 150 percent. LBC-LOW Laser bias current minimum. Cisco default is (15 min): 50 percent. OPT-HIGH Optical power transmitted maximum. Cisco default is (15 min): 120 percent. OPT-LOW Optical power transmitted minimum.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-109 Field Descriptions for the Line Tab (continued) Field Description Port No. Port number. LBC-HIGH Laser bias current maximum. LBC-LOW Laser bias current minimum. OPT-HIGH Optical power transmitted maximum. OPT-LOW Optical power transmitted minimum. OPR-HIGH Optical power received maximum. OPR-LOW Optical power received minimum.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-110 Field Descriptions for the VC-4 Tab (continued) Field Description Customer ID The user-defined customer ID number. Service ID The user-defined service ID number. D.4.4.7 STS Tab (ONS 15454 SONET) The STS tab allows you to view and update OC192/STM64 XFR-based card STS information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-111 Field Descriptions for the STS Tab (continued) Field Description PJCS-Pdet Positive pointer justification count, STS path detected. PJCS-Pgen Positive pointer justification count, STS path generated. PJC-Diff The sum of the absolute values of differences between positive transmitted and received, and negative transmitted and received.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-112 Field Descriptions for the Loopback Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.4.10 Alarm Behavior Tab The Alarm Behavior tab allows you to view and update OC192/STM64 XFR-based card alarm profile information. Table D-114 Field Descriptions for the Alarm Behavior Tab Field Description Alarm Profile Displays the alarm profile that has been configured for the card. Suppress Alarms If checked, indicates that all alarms are suppressed for the card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-116 Field Descriptions for the Auto Laser Shutdown Tab (continued) Field Description Status Displays the current laser status. Values are Shutdown or Not Shutdown. Request Restart If selected, it allows you to request a laser restart. This parameter is configurable only when the ALS mode is set to Manual Restart or Manual Restart for Test and when the laser status is Shut Down. D.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.4.15 Info Tab The Info tab allows you to view nominal operating values set during manufacturing for the OC192/STM64 XFR-based card. Table D-119 Field Descriptions for the Info Tab Field Description Extended Manufacturing Information Attribute Displays the nominal card specification. Value Displays the value of the attribute.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-120 Field Descriptions for the Identification Tab (continued) Field Description Hardware Part Number Displays the card part number that is printed on the top of the card. Hardware Revision Displays the hardware revision number. Serial Number Displays the card serial number that is unique to each card. CLEI Code Displays the CLEI code.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.5.3 Line Tab The Line tab allows you to view and update OC3 IR 4/STM1 SH 1310 optical line performance monitoring information. Table D-121 Field Descriptions for the Line Tab Field Description Line Config Port Number Displays the optical port number. Port Name Allows you to enter the name of the optical port. SD BER Sets the signal degrade bit error rate.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-121 Field Descriptions for the Line Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-121 Field Descriptions for the Line Tab (continued) Field Description FC-L Failure count–line PSC Protection switching count—Near-end only PSD Protection switching duration—Near-end only Line Thresh 1 Day Port Number The optical port number ES-L Errored seconds–line SES-L Severely errored seconds–line CV-L Coding violations–line UAS-L Unavailable seconds–line FC-L Failu
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-122 Field Descriptions for the STS Tab (continued) Field Description SES-P Severely errored seconds–path UAS-P Unavailable seconds–path FC-P Failure count–path PPJC-Pdet Positive pointer justification count, STS path detected NPJC-Pdet Negative pointer justification count, STS path detected PPJC-Pgen Positive pointer justification count, STS path generated NPJC-Pgen Negativ
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-123 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number. Admin State Displays the status of the line. The line can be In Service (IS), In Service–Auto In Service Soak (IS_AINS), Out of Service (OOS), or Out of Service–Maintenance (OOS_MT).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.5.7 Alarm Behavior Tab The Alarm Behavior tab allows you to view and update OC3 IR 4/STM1 SH 1310 alarm profile information. Table D-125 Field Descriptions for the Alarm Behavior Tab Field Description Alarm Profile Displays the alarm profile that has been configured for the card. Suppress Alarms If checked, indicates that all alarms are suppressed for the card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-127 Field Descriptions for the Info Tab Field Description Extended Manufacturing Information Attribute Displays the nominal card specification. Value Displays the value of the attribute. Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-128 Field Descriptions for the Identification Tab (continued) Field Description Serial Number Displays the card serial number that is unique to each card. CLEI Code Displays the CLEI code. Firmware Version Displays the revision number of the software used by the ASIC chip installed on the card. Product ID Displays a product ID string of 63 characters maximum.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.6.3 Line Tab The Line tab allows you to view and update OC3 IR/STM1 SH 1310-8 optical line performance monitoring information. Table D-129 Field Descriptions for the Line Tab Field Description Line Config Port Number Displays the optical port number. Port Name Allows you to enter the name of the optical port. SD BER Sets the signal degrade bit error rate.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-129 Field Descriptions for the Line Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-129 Field Descriptions for the Line Tab (continued) Field Description FC-L Failure count–line PSC Protection switching count—Near-end only PSD Protection switching duration—Near-end only Line Thresh 1 Day Port Number The optical port number ES-L Errored seconds–line SES-L Severely errored seconds–line CV-L Coding violations–line UAS-L Unavailable seconds–line FC-L Failu
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-130 Field Descriptions for the STS Tab (continued) Field Description SES-P Severely errored seconds–path UAS-P Unavailable seconds–path FC-P Failure count–path PPJC-Pdet Positive pointer justification count, STS path detected NPJC-Pdet Negative pointer justification count, STS path detected PPJC-Pgen Positive pointer justification count, STS path generated NPJC-Pgen Negativ
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-131 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number. Admin State Displays the status of the line. The line can be In Service (IS), In Service–Auto In Service Soak (IS_AINS), Out of Service (OOS), or Out of Service–Maintenance (OOS_MT).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.6.7 Alarm Behavior Tab The Alarm Behavior tab allows you to view and update OC3 IR/STM1 SH 1310-8 alarm profile information. Table D-133 Field Descriptions for the Alarm Behavior Tab Field Description Alarm Profile Displays the alarm profile that has been configured for the card. Suppress Alarms If checked, indicates that all alarms are suppressed for the card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-135 Field Descriptions for the J1 Path Trace Tab (continued) Field Description Mode Displays the path trace mode (Off/None, Auto, or Manual). C2 Represents a machine-generated J1/J2 payload label byte. Mismatch Indicates whether there is a mismatch in the C2 byte received. Vcat Member Number Displays the virtual concatenation (VCAT) member number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.7.2 Identification Tab The Identification tab allows you to view and update OC48 identification information. Table D-137 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-138 Field Descriptions for the Line Tab (continued) Subfield Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-138 Field Descriptions for the Line Tab (continued) Subfield Description ES-S Errored seconds–section. SES-S Severely errored seconds–section. SEFS-S Severely errored framing seconds–section. Section Thresh 1 Day Port Number The optical port number. CV-S Coding violations–section. ES-S Errored seconds–section. SES-S Severely errored seconds–section.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-138 Field Descriptions for the Line Tab (continued) Subfield Description PSC Protection switching count. PSD Protection switching duration. PSC-W Protection switching count–working. PSD-W Protection switching duration–working. Far End Port Number The optical port number. ES-L Errored seconds–line. SES-L Severely errored seconds–line. CV-L Coding violations–line.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.7.4 STS Tab The STS tab allows you to view and update OC48 STS information. Table D-139 Field Descriptions for the STS Tab Field Description STS Config Displays the STS number, intermediate path protection monitoring (IPPM), and XC loopback status.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.7.5 Loopback Tab The Loopback tab allows you to view and update OC48 loopback information. Table D-140 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number. State Displays the current state of the port. Loopback Type Allows you to configure a port to terminal loopback (Inward) or clear the current loopback (none). D.4.7.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.7.9 J1 Path Trace Tab The J1 Path Trace tab allows you to view the OC48 J1 path trace information. Table D-144 Field Descriptions for the J1 Path Trace Tab Field Description Port Number Displays the port number. VC Number Displays the VC number. Expected String Displays the current expected string. Received String Displays the current received string.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.8.2 Identification Tab The Identification tab allows you to view and update OC48 IR 1310 identification information. Table D-145 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-145 Field Descriptions for the Identification Tab (continued) Field Description Service State Overall availability of the entity. Values are: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-146 Field Descriptions for the Line Tab (continued) Subfield Description PJSTSMon# Sets the STS that will be used for pointer justification. If set to 0, no STS is monitored. Only one STS can be monitored on each OC-N port.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-146 Field Descriptions for the Line Tab (continued) Subfield Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-146 Field Descriptions for the Line Tab (continued) Subfield Description PSC-S Protection switching count—span PSD-S Protection switching duration—span PSC-R Protection switching count—ring PSD-R Protection switching duration—ring Far End Port Number The optical port number ES-L Errored seconds–line SES-L Severely errored seconds–line CV-L Coding violations–line UAS-L U
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-146 Field Descriptions for the Line Tab (continued) Subfield Description CV-S Coding violations–section ES-S Errored seconds–section SES-S Severely errored seconds–section SEFS-S Severely errored framing seconds–section Section Threshold 1 Day Port Number The optical port number CV-S Coding violations–section ES-S Errored seconds–section SES-S Severely errored seconds–se
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-147 Field Descriptions for the STS Tab (continued) Field Description ES-P Errored seconds–path SES-P Severely errored seconds–path UAS-P Unavailable seconds–path FC-P Failure count–path PPJC-Pdet Positive pointer justification count, STS path detected NPJC-Pdet Negative pointer justification count, STS path detected PPJC-Pgen Positive pointer justification count, STS path ge
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.8.7 Alarm Behavior Tab The Alarm Behavior tab allows you to view and update OC48 IR 1310 alarm profile information. Table D-150 Field Descriptions for the Alarm Behavior Tab Field Description Alarm Profile Displays the alarm profile that has been configured for the card. Suppress Alarms If checked, indicates that all alarms are suppressed for the card.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-152 Field Descriptions for the J1 Path Trace Tab Field Description Port Number Displays the port number. STS Number Displays the STS number. Expected String Displays the current expected string. Received String Displays the current received string. Mode Displays the path trace mode (Off/None, Auto, or Manual). C2 Represents a machine-generated J1/J2 payload label byte.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.9.2 Identification Tab The Identification tab allows you to view and update OC48 LR 1550 identification information. Table D-153 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-153 Field Descriptions for the Identification Tab (continued) Field Description Equipment State Displays the equipment state of the card. Alarm Profile Sets the alarm profile for the port. Check the Suppress Alarms check box to suppress all alarms for this card and its port(s). D.4.9.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-154 Field Descriptions for the Line Tab (continued) Subfield Description Admin SSM If the node does not receive an SSM signal, it defaults to STU (synchronization traceability unknown).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-154 Field Descriptions for the Line Tab (continued) Subfield Description ES-L Errored seconds–line SES-L Severely errored seconds–line CV-L Coding violations–line UAS-L Unavailable seconds–line FC-L Failure count–line PSC Protection switching count–Near-end only PSD Protection switching duration–Near-end only PSC-W Protection switching count–working PSD-W Protection swit
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-155 Field Descriptions for the STS Tab Field Description STS Config Displays the STS number, the intermediate path protection monitoring (IPPM) status, and XC loopback status.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-155 Field Descriptions for the STS Tab (continued) Field Description Customer ID The user-defined customer ID number Service ID The user-defined service ID number D.4.9.5 Loopback Tab The Loopback tab allows you to view and update OC48 LR 1550 loopback information. Table D-156 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-157 Field Descriptions for the Protection Tab Field Description Protection Groups Displays a list of available protection groups. Protection Group Details Displays details about the selected protection group. D.4.9.7 Alarm Behavior Tab The Alarm Behavior tab allows you to view and update OC48 LR 1550 alarm profile information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-160 Field Descriptions for the Info Tab Field Description Extended Manufacturing Information Attribute Displays the nominal card specification. Value Displays the value of the attribute. Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Figure D-1 Cisco ONS 15808 Odd/Even Channel Processor–L Band OECP-L modules shown on this sheet include: • Odd/Even Channel Processor–L band–Active (OECP-L) • Odd/Even Channel Processor–L band–Passive (OECP-L--P) For ONS 15808 OECP-L modules, the Slot Properties pane displays the following tabs: Module View, Identification, Temperature, and Input Power. D.4.10.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-161 Field Descriptions for the Identification Tab (continued) Field Description Slot ID Displays the identification number of the slot containing the OECP-L module. Software Version Displays the version of the software. BIOS Version Displays the version number of the BIOS. Board Serial Number Displays the serial number of the board.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-163 Field Descriptions for the Input Power Tab (continued) Field Description Fail Sets the fail threshold for the Laser 1 input power, in dBm, and the alarm severity level. Degrade Sets the degrade threshold for the Laser 1 input power, in dBm, and the alarm severity level. High Sets the high threshold for the Laser 1 input power, in dBm, and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.11.2 Identification Tab The Identification tab allows you to view and update S1.1-2-LC identification information. Table D-164 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.11.4 VC-4 Config Tab The VC-4 Config tab allows you to view and update S1.1-2-LC VC-4 information. Table D-166 Field Descriptions for the VC-4 Config Tab Field Description VC Number Displays the VC number. IPPM Enabled Check to enable intermediate path performance monitoring (IPPM) and uncheck to disable IPPM. XC Loopback Indicates cross-connect loopback. D.4.11.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.12.1 Module View Tab The Module View tab displays a graphic of the S1.1-8-LC that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Alarms are also displayed when you move the mouse pointer over the graphic.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.12.4 WAN Line Tab The WAN Line tab allows you to view and configure wide-area network (WAN) line information. Table D-170 Field Descriptions for the WAN Line Tab Field Description Port Number Displays the optical port number. Port Name Allows you to enter an optical port name. Link State Displays the physical port state. Possible values are Up, Down, or Not Present.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.13.2 Identification Tab The Identification tab allows you to view and update S16.1-1-LC identification information. Table D-171 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.13.4 VC-4 Config Tab The VC-4 Config tab allows you to view and update S16.1-1-LC information. Table D-173 Field Descriptions for the VC-4 Config Tab Field Description VC Number Displays the VC number. IPPM Enabled Check to enable intermediate path performance monitoring (IPPM) and uncheck to disable IPPM. XC Loopback Indicates cross-connect loopback. D.4.13.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.14.2 Identification Tab The Identification tab allows you to view and update STM-1 identification information. Table D-175 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-176 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-176 Field Descriptions for the Line Tab (continued) Field Description ES-RS Errored seconds–regenerator section SES-RS Severely errored seconds–regenerator section UAS-RS Unavailable seconds–regenerator section OFS-RS Out of framing seconds–regenerator section MS Threshold 15 Minutes Port Number The port number EB-MS Errored block BBE-MS Background block errors ES-MS Erro
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.14.4 VC-4 Tab The VC-4 tab allows you to view and update STM-1 VC-4 information. Table D-177 Field Descriptions for the VC-4 Tab Field Description VC-4 Displays the VC-4 number, the intermediate path protection monitoring (IPPM) status, and the XC loopback status. The XC Loopback field only appears on ONS 15454 SDH Release 4.0. Threshold 15 Minutes VC Number The VC number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.14.6 Protection Tab The Protection tab allows you to view and update STM-1 protection group information. Table D-179 Field Descriptions for the Protection Tab Field Description Protection Groups Displays a list of available protection groups. Protection Group Details Displays details about the selected protection group. D.4.14.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.14.9 J1 Path Trace Tab The J1 Path Trace tab allows you to view and retrieve J1 path trace information. Table D-182 Field Descriptions for the J1 Path Trace Tab Field Description Port Number Displays the port number. STS Number Displays the STS number. Expected String Displays the current expected string. Received String Displays the current received string.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.15.1 Module View Tab The Module View tab displays a graphic of the S1.1-2-LC/E1-21 that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Alarms are also displayed when you move the mouse pointer over the graphic.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.15.4 E1 Line Tab The E1 Line tab allows you to view and update S1.1-2-LC/E1-21 optical line performance monitoring information. Table D-185 Field Descriptions for the E1 Line Tab Field Description Port Number Displays the optical port number. Port Name Allows you to enter an optical port name. Line Type Allows you to select the line framing type.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.16.2 Identification Tab The Identification tab allows you to view and update STM-1E-12 identification information. Table D-186 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-187 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-187 Field Descriptions for the Line Tab (continued) Field Description BBE-RS(FE) Background block errors–regenerator section UAS-RS Unavailable seconds–regenerator section OFS-RS Out of framing seconds–regenerator section RS Threshold 1 Day Port Number The port number ES-RS Errored seconds–regenerator section SEFS-RS Severely errored framing seconds–regenerator section EB-RS
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-188 Field Descriptions for the VC-4 Tab (continued) Field Description EB-HP Errored block–higher order path. BBE-HP Background block errors–higher order path. ES-HP Errored seconds–higher order path. SES-HP Severely errored seconds–higher order path. UAS-P Unavailable seconds–higher order path. Threshold 1 Day VC Number The VC number. EB-HP Errored block–higher order path.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.16.6 Protection Tab The Protection tab allows you to view and update STM-1E-12 protection group information. Table D-190 Field Descriptions for the Protection Tab Field Description Protection Groups Displays a list of available protection groups. Protection Group Details Displays details about the selected protection group. D.4.16.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.4.17 Slot Properties—STM-16 (ONS 15454 SDH) The Slot Properties pane displays information about the Cisco ONS 15454 SDH slot that is selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.17.3 Line Tab The Line tab allows you to view and update STM-16 line performance monitoring information. Table D-194 Field Field Descriptions for the Line Tab Description Line Config Port Number Displays the optical port number. Port Name Allows you to enter an optical port name. SD BER Sets the signal degrade bit error rate. SF BER Sets the signal fail bit error rate.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-194 Field Descriptions for the Line Tab (continued) Field Description AINS Soak Automatic in-service soak. The determination of duration left before the traffic/termination transitions to IS state. AINS Soak Count Down Automatic in-service soak countdown. Displays the remaining time of valid input signal in hh:mm, after which the card becomes in service (IS) automatically.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-194 Field Descriptions for the Line Tab (continued) Field Description EB-MS Errored block BBE-MS Background block errors ES-MS Errored seconds SES-MS Severely errored seconds UAS-MS Unavailable seconds PPJC-PDET Positive pointer justification count, path detected NPJC-PDET Negative pointer justification count, path detected PPJC-PGEN Positive pointer justification count, p
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-195 Field Descriptions for the VC-4 Tab (continued) Field Description Customer ID The user-defined customer ID number. Service ID The user-defined service ID number. D.4.17.5 Loopback Tab The Loopback tab allows you to view and update STM-16 loopback information. Table D-196 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.17.8 Auto Laser Shutdown Tab The Auto Laser Shutdown tab allows you to view and update ALS parameters. Table D-199 Field Descriptions for the Auto Laser Shutdown Tab Field Description Port No. Displays the port number. ALS Mode Displays the auto laser shutdown mode (Disabled, Auto Restart, Manual Restart, or Manual Restart for Test). Rec. Pulse Dur.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards For the STM-16 module, the Slot Properties pane displays the following tabs: Module View, Identification, Line, VC-4, Loopback, Transceiver, Protection, Alarm Behavior, and J1 Path Trace. D.4.18.1 Module View Tab The Module View tab displays a graphic of the STM16 that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-202 Field Descriptions for the Line Tab (continued) Field Description SD BER Sets the signal degrade bit error rate. SF BER Sets the signal fail bit error rate. ProvidesSync If checked, the card is provisioned as an NE timing reference. EnableSyncMsg Enables synchronization status messages (S1 byte), which allow the node to choose the best timing source.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-202 Field Descriptions for the Line Tab (continued) Field Description BBE-MS Background block errors–multiplex section UAS-MS Unavailable seconds–multiplex section PSC Protection switching count PSD Protection switching duration PSC-W Protection switching count–working PSD-W Protection switching duration–working MS Thresh 15 Min (Far End) Port Number The port number EB-MS
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-202 Field Descriptions for the Line Tab (continued) Field Description SES-RS Severely errored seconds–regenerator section RS Thresh 1 Day (Near End) Port Number The port number EB-RS Errored block–regenerator section BBE-RS Background block errors–regenerator section ES-RS Errored seconds–regenerator section SES-RS Severely errored seconds–regenerator section Physical Thresh
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-203 Field Descriptions for the VC-4 Tab (continued) Field Description Path Thresh 15 Min (Near End) VC Number The VC number. EB-HP Errored block–higher order path. BBE-HP Background block errors–higher order path. ES-HP Errored seconds–higher order path. SES-HP Severely errored seconds–higher order path. UAS-P Unavailable seconds–higher order path.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-203 Field Descriptions for the VC-4 Tab (continued) Field Description Customer Info VC Number The VC number. Customer ID The user-defined customer ID number. Service ID The user-defined service ID number. D.4.18.5 Loopback Tab The Loopback tab allows you to view and update STM-16 loopback information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.18.6 Transceiver Tab The Transceiver tab allows you to view and update STM-16 transceiver information. Table D-205 Field Descriptions for the Transceiver Tab Field Description Port No Port No. Port number 1–14. Non-normalized LBC (mA) The actual operating value of laser bias current (in mA) for the specified card port.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-208 Field Descriptions for the J1 Path Trace Tab Column Description Port Number Displays the port number. VC Number Displays the VC number. Expected String Displays the current expected string. Received String Displays the current received string. Mode Displays the path trace mode (Off/None, Auto, or Manual). C2 Represents a machine-generated J1/J2 payload label byte.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.19.2 Identification Tab The Identification tab allows you to view and update STM-4 IR/STM4 SH 1310 identification information. Table D-209 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-210 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-210 Field Descriptions for the Line Tab (continued) Field Description ES-RS Errored seconds–regenerator section SES-RS Severely errored seconds–regenerator section UAS-RS Unavailable seconds–regenerator section OFS-RS Out of framing seconds–regenerator section MS Threshold 15 Minutes Port Number The port number EB-MS Errored block BBE-MS Background block errors ES-MS Err
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.19.4 VC-4 Tab The VC-4 tab allows you to view and update STM-4 IR/STM4 SH 1310 VC-4 information. Table D-211 Field Descriptions for the VC-4 Tab Field Description VC-4 Displays the VC-4 number, the intermediate path protection monitoring (IPPM) status, and the XC loopback status. Threshold 15 Minutes VC Number The VC number. EB-HP Errored block–higher order path.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.19.6 Protection Tab The Protection tab allows you to view and update STM-4 IR/STM4 SH 1310 protection group information. Table D-213 Field Descriptions for the Protection Tab Field Description Protection Groups Displays a list of available protection groups. Protection Group Details Displays details about the selected protection group. D.4.19.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.20 Slot Properties—STM-4 L4.2-2-LC (ONS 15305 CTC) This is a dual-port STM4 module for long-haul transmission at 1550 nm optical wavelength. The main functions of the module are O/E-E/O conversion and SDH multi/demultiplexing with VC-12, VC-3, and VC-4 granularity. A module diagram is shown in the following figure. STM-4 L4.2-2-LC Module STM-4 L4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-216 Field Descriptions for the Identification Tab (continued) Field Description Version ID Displays a version ID string in the format “V99_.” The version ID always begins with a V and ends with a space. If the card does not support the version ID, the field shows N/A. Equipment State Displays the equipment state of the card. Alarm Profile Displays the alarm profile for the port.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-219 Field Descriptions for the Loopback Tab (continued) Field Description Admin State Displays the current loopback state. Loopback Type Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current loopback (None). The line state must be OOS_MT before you can configure the loopback type.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-220 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot. HW Part Number Displays the card part number that is printed on the top of the card. Hardware Revision Displays the hardware version number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.21.5 Loopback Tab The Loopback tab allows you to view and update L16.2-1-LC loopback information. Table D-223 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number. Admin State Displays the current loopback state. Loopback Type Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current loopback (None).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-224 Field Descriptions for the Identification Tab (continued) Field Description Part Number Displays the card part number that is printed on the top of the card. Hardware Revision Displays the hardware revision number of the card. Serial Number Displays the card serial number that is unique to each card. CLEI Code Displays the CLEI code.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-225 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-225 Field Descriptions for the Line Tab (continued) Field Description ES-RS Errored seconds–regenerator section. SES-RS Severely errored seconds–regenerator section. UAS-RS Unavailable seconds–regenerator section. OFS-RS Out of framing seconds–regenerator section. MS Threshold 15 Minutes Port Number The port number. EB-MS Errored blocks. BBE-MS Background block errors.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.22.4 VC-4 Tab The VC-4 tab allows you to view and update STM-64 LH 1550 VC-4 information. Table D-226 Field Descriptions for the VC-4 Tab Field Description VC-4 Displays the VC-4 number, the intermediate path protection monitoring (IPPM) status, and the XC loopback status. The XC Loopback field only appears on the ONS 15454 SDH R4.0. Path Threshold 15 Minutes VC Number The VC number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.22.6 Protection Tab The Protection tab allows you to view and update STM-64 LH 1550 protection group information. Table D-228 Field Descriptions for the Protection Tab Field Description Protection Groups Displays a list of available protection groups. Protection Group Details Displays details about the selected protection group. D.4.22.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.22.9 J1 Path Trace Tab The J1 Path Trace tab allows you to view and retrieve STM-64 LH 1550 J1 path trace information. Table D-231 Field Descriptions for the J1 Path Trace Tab Field Description Port Number Displays the port number. STS Number Displays the STS number. Expected String Displays the current expected string. Received String Displays the current received string.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-232 Field Descriptions for the Identification Tab Field Description Equipment Type Displays the equipment type the slot is provisioned for. Actual Equipment Type Displays the actual card that is installed in the slot. HW Part Number Displays the card part number that is printed on the top of the card. Hardware Revision Displays the hardware revision number.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-233 Field Descriptions for the Line Tab (continued) Field Description Service State Displays the service state: • IS_NR—In Service–Normal. • OOS_AU—Out of Service–Autonomous. • OOS_MA—Out of Service–Management. • OOS_AUMA—Out of Service–Autonomous and Management. In addition, a secondary state provides additional information about the status of the entity.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-233 Field Descriptions for the Line Tab (continued) Field Description EB-MS Errored block–multiplex section ES-MS Errored seconds–multiplex section SES-MS Severely errored seconds–multiplex section BBE-MS Background block errors–multiplex section UAS-MS Unavailable seconds–multiplex section MS Thresh 1 Day (Near End) Port Number The port number EB-MS Errored block–multiple
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-233 Field Descriptions for the Line Tab (continued) Field Description Port Number Port number LBC-HIGH High laser bias current threshold LBC-LOW Low laser bias current threshold OPT-HIGH High optical power transmitted threshold OPT-LOW Low optical power transmitted threshold OPR-HIGH High optical power received threshold OPR-LOW Low optical power received threshold SET-OPR
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-234 Field Field Descriptions for the VC-4 Tab (continued) Description Path Thresh 15 Min (Far End) VC Number The VC number. EB-HP Errored block–higher order path. BBE-HP Background block errors–higher order path. ES-HP Errored seconds–higher order path. SES-HP Severely errored seconds–higher order path. UAS-P Unavailable seconds–higher order path.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards Table D-235 Field Descriptions for the Loopback Tab Field Description Port Number Displays the port number. Admin State Shows the administrative state of the port: In Service (IS), Out of Service–Disabled (OOS, DSBLD), or Out of Service–Maintenance (OOS_MT). Loopback Type Allows you to configure a port to terminal loopback (Inward) or Facility (Line), or clear the current loopback (None).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Optical Cards D.4.23.7 Protection Tab The Protection tab allows you to view and update STM-64 LR/LH 4 protection group information. Table D-237 Field Descriptions for the Protection Tab Field Description Protection Groups Displays a list of available protection groups. Protection Group Details Displays details about the selected protection group. D.4.23.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.5 Transponder Cards This section describes the following transponder cards supported within CTM: • D.5.1 Slot Properties—BT10E-LCxx and BT10E-LLxx, page D-213 • D.5.2 Slot Properties—FEC-LEM, page D-219 • D.5.3 Slot Properties—LEM, page D-223 • D.5.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.1.1 Module View Tab The Module View tab displays a graphic of the transponder that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Moving the mouse pointer over the graphic also displays the alarm counts.) The module status is displayed under Operational State.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.1.3.1 Temperature Subtab The Temperature subtab allows you to assign temperature-related thresholds and alarm severities for the transponder laser. Table D-241 Field Field Descriptions for the Temperature Subtab Description Laser 1 Value When the Update button is clicked, displays the current temperature of Laser 1 (in degrees Celsius).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-244 Field Field Descriptions for the Input Power Subtab Description Input Power 1 Value When the Update button is clicked, displays the current transponder input power (in dBm). Fail Sets the failure threshold for the input power, in dBm, and the alarm severity level. Low Sets the low threshold for the input power, in dBm, and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.1.4 Receive Direction Tab The Receive Direction tab allows you to configure the BT10E-LCxx and BT10E-LLxx receive direction properties. The Receive Direction tab contains the following subtabs: • D.5.1.4.1 Input Power Subtab, page D-217 • D.5.1.4.2 Output Power Subtab, page D-217 • D.5.1.4.3 QoS 15 Min and QoS 1 Day Subtabs, page D-217 D.5.1.4.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-249 Field Descriptions for the QoS 15 Min and QoS 1 Day Subtabs Field Description Errored Seconds Sets the high threshold for the number of FEC errored seconds (ES) and the alarm severity level. An errored second is a one-second period with one or more error blocks or at least one defect.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.5.2 Slot Properties—FEC-LEM The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-251 Field Descriptions for the Identification Tab Field Description NE ID Displays the user-defined name of the NE where the transponder is installed. Description Displays information that a user has entered (if any) to describe the NE. NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the transponder is installed.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-253 Field Descriptions for the Quality of Service Tab Field Description FEC Counters Errored Seconds Sets the high threshold for the number of FEC errored seconds (ES) and the alarm severity level. Severely Errored Seconds Sets the high threshold for the number of FEC severely errored seconds (SES) and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.2.7 Input Power Tab The Input Power tab allows you to assign thresholds and alarm severities for the power coming into the transponder. Table D-256 Field Descriptions for the Input Power Tab Field Description Value When the Update button is clicked, displays the current transponder input power. Low Sets the low threshold for the module input power in dBm and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.3 Slot Properties—LEM The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-259 Field Descriptions for the Identification Tab (continued) Field Description Slot ID Displays the identification number of the slot containing the transponder. Software Version Displays the version of the software running on the module. BIOS Version Displays the version number of the BIOS. Board Serial Number Displays the serial number of the board.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-262 Field Descriptions for the Power Tab Field Description Value When the Update button is clicked, displays the current power of Laser 1. Low Sets the low threshold for the laser power (in mW) and the alarm severity level. High Sets the high threshold for the laser power (in mW) and the alarm severity level. D.5.3.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Figure D-10 Cisco ONS 15800 or ONS 15801 Line Extender Module–10-Gbps–B1 Monitoring The ONS 15800 or ONS 15801 transponder modules shown on this sheet include: • Line Extender Module–10 Gbps–B1 Monitoring (LEM-10G-Mxx) • Line Extender Module–10 Gbps High Output Power–B1 Monitoring (LEM-10H-Mxx) For these transponders, the Slot Properties pane displays the following tabs: Module View, Iden
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-265 Field Descriptions for the Identification Tab (continued) Field Description Board Serial Number Displays the serial number of the board. SCC Number Displays the version of the module serial communication controller (SCC). Product Option Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than version 2.1.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-267 Field Descriptions for the Quality of Service Tab (continued) Field Description Background Block Errors Sets the high threshold for the number of B1 background block errors (BBE) and the alarm severity level. An errored block is a block in which one or more bits are in error. A background block error is an errored block that does not occur as part of a severely errored second.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.4.8 Output Power Tab The Output Power tab allows you to assign performance monitoring thresholds for the transponder output power. Table D-271 Field Descriptions for the Output Power Tab Field Description Value When the Update button is clicked, displays the current transponder output power.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.5.2 Identification Tab The Identification tab allows you to view and update transponder identification information. Table D-272 Field Descriptions for the Identification Tab Field Description NE ID Displays the user-defined name of the NE where the transponder is installed. Description Displays information that a user has entered (if any) to describe the NE.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-274 Field Descriptions for the Current Tab Field Description Value When the Update button is clicked, displays the current value of the laser current. Degrade Sets the degrade threshold for the laser current (in mA) and the alarm severity level. Fail Sets the failure threshold for the laser current (in mA) and the alarm severity level. D.5.5.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.5.6 Slot Properties—LEM-EM-M The Slot Properties pane displays information about the Line Extender Module–Externally Modulated–B1 Monitoring (LEM-EM-M) that is installed in the slot selected in the NE Explorer tree.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-278 Field Descriptions for the Identification Tab Field Description NE ID Displays the user-defined name of the NE where the transponder is installed. Description Displays information that a user has entered (if any) to describe the NE. NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the transponder is installed.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-280 Field Descriptions for the Quality of Service Tab Field Description Errored Seconds Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity level. An errored second is a one-second period with one or more error blocks or at least one defect.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-283 Field Descriptions for the Input Power Tab Field Description Value When the Update button is clicked, displays the current transponder input power. Low Sets the low threshold for the module input power in dBm and the alarm severity level. High Sets the high threshold for the module input power (in dBm) and the alarm severity level. D.5.6.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Figure D-13 Cisco ONS 15808 Line Transponder Line transponders shown on this sheet include: • Line Transponder–2.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-285 Field Descriptions for the Identification Tab (continued) Field Description Software Version Displays the version of the software. BIOS Version Displays the version number of the BIOS. Board Serial Number Displays the serial number of the board. SCC Number Displays the version of the module serial communication controller (SCC).
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-287 Field Descriptions for the Quality of Service Tab (continued) Field Description Background Block Errors Sets the high threshold for the number of FEC background block errors (BBE) and the alarm severity level. An errored block is a block in which one or more bits are in error. A background block error is an errored block that does not occur as part of a severely errored second.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-290 Field Descriptions for the Input Power Tab Field Description Input Power 1 Value When the Update button is clicked, displays the current transponder input power (in dBm). Low Sets the low threshold for the input power, in dBm, and the alarm severity level. High Sets the high threshold for the input power, in dBm, and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.8 Slot Properties—RT The Slot Properties pane displays information about the Cisco ONS 15808 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds. The receiver transponder is used in terminal sites (receive direction) and in OADM sites to retime, reshape, and regenerate 2.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Operational State. Right-clicking the graphic opens a shortcut menu that you can use to display the module in the Equipment Inventory Table, in the Alarm Browser, or in the Receiver Transponders PM Table. D.5.8.2 Identification Tab The Identification tab allows you to view and update transponder identification information.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-294 Field Descriptions for the Quality of Service Tab (continued) Field Description Background Block Errors Sets the high threshold for the number of B1 background block errors (BBE) and the alarm severity level. An errored block is a block in which one or more bits are in error. A background block error is an errored block that does not occur as part of a severely errored second.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.8.5 Power Tab The Power tab allows you to assign thresholds and alarm severities for the transponder laser power levels. Table D-296 Field Descriptions for the Power Tab Field Description Laser 1 Value When the Update button is clicked, displays the current power of Laser 1 (in mW). Low Sets the low threshold for the Laser 1 power, in mW, and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.9 Slot Properties—RXT The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to change the module performance monitoring thresholds.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-299 Field Descriptions for the Identification Tab (continued) Field Description Slot ID Displays the identification number of the slot containing the receive transponder. Software Version Displays the version of the software. BIOS Version Displays the version number of the BIOS. Board Serial Number Displays the serial number of the board.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.9.5 Input Power Tab The Input Power tab allows you to assign performance monitoring thresholds for the power entering the receive transponder. Table D-302 Field Field Descriptions for the Input Power Tab Description Input Power Value When the Update button is clicked, displays the current receive transponder input power.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards For the RXT-10G-N module, the Slot Properties pane displays the following tabs: Module View, Identification, Current, Power, Input Power, and Output Power. Fields on these tabs are described in the following sections. D.5.10.1 Module View Tab The Module View tab displays a graphic of the transponder that is installed in the slot.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-305 Field Field Descriptions for the Current Tab Description Laser 1 Current Value When the Update button is clicked, displays the Laser 1 current of the receive transponder. Degrade Sets the degrade threshold for the Laser 1 current (in mA) and the alarm severity level. Fail Sets the failure threshold for the Laser 1 current (in mA) and the alarm severity level. D.5.10.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-308 Field Descriptions for the Output Power Tab (continued) Field Description Low Sets the low threshold for the receive transponder output power (in dBm) and the alarm severity level. High Sets the high threshold for the receive transponder output power (in dBm) and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.11.2 Identification Tab The Identification tab allows you to view and update receive transponder identification information. Table D-309 Field Descriptions for the Identification Tab Field Description NE ID Displays the user-defined name of the NE where the receive transponder is installed. Description Displays information that a user has entered (if any) to describe the NE.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-310 Field Descriptions for the Quality of Service Tab (continued) Field Description Background Block Errors Sets the high threshold for the number of B1 background block errors (BBE) and the alarm severity level. An errored block is a block in which one or more bits are in error. A background block error is an errored block that does not occur as part of a severely errored second.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-313 Field Field Descriptions for the Input Power Tab Description Input Power Value When the Update button is clicked, displays the current receive transponder input power. Fail Sets the fail threshold for the receive transponder input power (in dBm) and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Figure D-18 Cisco ONS 15800 or ONS 15801 Receive Transponder–B1 Monitoring RXTs shown on this sheet include: • Receive Transponder–Directly Modulated–B1 Monitoring module (RXT-DM-M) • Receive Transponder–Directly Modulated Long-Haul–B1 Monitoring module (RXT-DMLH-M) For these RXT modules, the Slot Properties pane displays the following tabs: Module View, Identification, Quality of Service,
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-315 Field Descriptions for the Identification Tab (continued) Field Description Board Serial Number Displays the serial number of the board. SCC Number Displays the SCC number. Product Option Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than version 2.1. Hardware Version Displays the version of the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-317 Field Descriptions for the Current Tab (continued) Field Description Degrade Sets the degrade threshold for the Laser 1 current (in mA) and the alarm severity level. Fail Sets the failure threshold for the Laser 1 current (in mA) and the alarm severity level. D.5.12.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Note See Table 1-20 on page 1-44 for descriptions of actions that can be performed using the buttons at the bottom of the window. D.5.13 Slot Properties—RXT-FEC The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 module that is installed in the slot selected in the NE Explorer tree.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-321 Field Descriptions for the Identification Tab (continued) Field Description SCC Number Displays the version of the module serial communication controller (SCC). Product Option Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than version 2.1. Hardware Version Displays the version of the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-322 Field Descriptions for the Quality of Service Tab (continued) Field Description Unavailable Seconds Sets the high threshold for the number of FEC UAS and the alarm severity level. The detection of 10 consecutive SES begins a period of UAS. The 10 SES detected are part of the UAS.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-325 Field Field Descriptions for the Input Power Tab Description Input Power Value When the Update button is clicked, displays the current receive transponder input power. Low Sets the low threshold for the receive transponder input power in dBm and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Figure D-19 Cisco ONS 15808 Transmitter Transponder Transmitter transponders shown on this sheet include: • Transmit Transponder–2.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-327 Field Descriptions for the Identification Tab (continued) Field Description Slot ID Displays the identification number of the slot containing the transponder. Software Version Displays the version of the software. BIOS Version Displays the version number of the BIOS. Board Serial Number Displays the serial number of the board.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-329 Field Descriptions for the Quality of Service Tab (continued) Field Description Background Block Errors Sets the high threshold for the number of B1 background block errors (BBE) and the alarm severity level. An errored block is a block in which one or more bits are in error. A background block error is an errored block that does not occur as part of a severely errored second.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-332 Field Field Descriptions for the Input Power Tab Description Input Power 1 Value When the Update button is clicked, displays the current transponder input power (in dBm). Low Sets the low threshold for the input power, in dBm, and the alarm severity level. High Sets the high threshold for the input power, in dBm, and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.15 Slot Properties—WCM The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 slot that is selected in the NE Explorer tree. Use this properties pane to set performance monitoring thresholds for the module.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-335 Field Descriptions for the Identification Tab (continued) Field Description Subrack ID Displays the identification number of the subrack containing the wavelength converter module. Slot ID Displays the identification number of the slot containing the wavelength converter module. Software Version Displays the version of the software.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.15.5 Power Tab The Power tab allows you to assign performance monitoring thresholds for the wavelength converter module Laser 1 power levels. Table D-338 Field Field Descriptions for the Power Tab Description Laser 1 Power Value When the Update button is clicked, displays the current power of Laser 1.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.16 Slot Properties—WCM-10G-Nxx The Slot Properties pane displays information about the module that is installed in the slot selected in the NE Explorer tree. Use this properties pane to set performance monitoring thresholds for the module.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-341 Field Descriptions for the Identification Tab (continued) Field Description SCC Number Displays the version of the module serial communication controller (SCC). Product Option Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than version 2.1. Hardware Version Displays the version of the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.16.5 Power Tab The Power tab allows you to assign performance monitoring thresholds for the wavelength converter module Laser 1 power levels. Table D-344 Field Field Descriptions for the Power Tab Description Laser 1 Power Value When the Update button is clicked, displays the current power of Laser 1.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.17 Slot Properties—WCM-FEC The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 slot that is selected in the NE Explorer tree. Use this properties pane to set performance monitoring thresholds for the module.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-347 Field Descriptions for the Identification Tab Field Description NE ID Displays the user-defined name of the NE where the wavelength converter module is installed. Description Displays information that a user has entered (if any) to describe the NE. NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the wavelength converter module is installed.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-349 Field Descriptions for the Quality of Service Tab Field Description B1 Counters Errored Seconds Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity level. An errored second is a one-second period with one or more error blocks or at least one defect.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-350 Field Field Descriptions for the Current Tab Description Laser 1 Current Value When the Update button is clicked, displays the Laser 1 current of the module. Degrade Sets the degrade threshold for Laser 1 current (in mA) and the alarm severity level. Fail Sets the failure threshold for Laser 1 current (in mA) and the alarm severity level. D.5.17.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-353 Field Descriptions for the Output Power Tab (continued) Field Description Low Sets the low threshold for the wavelength converter module Laser 1 output power (in dB) and the alarm severity level. High Sets the high threshold for the wavelength converter module Laser 1 output power (in dB) and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Figure D-23 Cisco ONS 15800 or ONS 15801 Wavelength Converter Module–Externally Modulated–Forward Error Correction For Wavelength Converter Modules–Externally Modulated–Forward Error Correction (WCM-EM-Fxx), the Slot Properties pane displays the following tabs: Module View, Identification, Temperature, Quality of Service, Current, Power, Input Power, Output Power, and Action. D.5.18.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-355 Field Descriptions for the Identification Tab (continued) Field Description SCC Number Displays the version of the module serial communication controller (SCC). Product Option Displays the product option. Displays “Not Available” if the TL1 Agent version is earlier than version 2.1. Hardware Version Displays the version of the hardware.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-357 Field Descriptions for the Quality of Service Tab (continued) Field Description Bit Error Rate Sets the high threshold for the B1 bit error rate (BER) and the alarm severity level. The BER is the ratio of received bits that contain errors. FEC Counters Errored Seconds Sets the high threshold for the number of FEC ES and the alarm severity level.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-359 Field Field Descriptions for the Power Tab Description Laser 1 Power Value When the Update button is clicked, displays the current power of Laser 1. Low Sets the low threshold for the laser power (in mW) and the alarm severity level. High Sets the high threshold for the laser power (in mW) and the alarm severity level. D.5.18.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-362 Field Descriptions for the Action Tab Field Description Output Power Setting The output power setting is used to activate the output power control mode on FEC transponders and force the transponder to regulate the optical output power.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.19.1 Module View Tab The Module View tab displays a graphic of the module that is installed in the slot. The number of critical, major, minor, and warning alarms for the module is displayed under Alarm Status. (Moving the mouse pointer over the graphic also displays the alarm counts.) The module status is displayed under Operational State.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-364 Field Field Descriptions for the Temperature Tab Description Laser 1 Temperature Value When the Update button is clicked, displays the current temperature of Laser 1. Low Sets the low temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level. High Sets the high temperature threshold for Laser 1 (in degrees Celsius) and the alarm severity level. D.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.19.6 Power Tab The Power tab allows you to assign performance monitoring thresholds for the wavelength converter module Laser 1 power levels. Table D-367 Field Descriptions for the Power Tab Field Description Laser 1 Power Value When the Update button is clicked, displays the current power of Laser 1.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.20 Slot Properties—WCM10 The Slot Properties pane displays information about the Cisco ONS 15800 or ONS 15801 slot that is selected in the NE Explorer tree. Use this properties pane to set performance monitoring thresholds for the module.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-370 Field Descriptions for the Identification Tab Field Description NE ID Displays the user-defined name of the NE where the module is installed. Description Displays information that a user has entered (if any) to describe the NE. NE Model Identifies the model of the selected NE (ONS 15800 or ONS 15801) where the module is installed.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards Table D-372 Field Descriptions for the Quality of Service Tab Field Description B1 Counters Errored Seconds Sets the high threshold for the number of B1 errored seconds (ES) and the alarm severity level. An errored second is a one-second period with one or more error blocks or at least one defect.
Appendix D Slot Property Information—FC_MR-4, FMEC, Multirate, Optical, and Transponder Cards Transponder Cards D.5.20.7 Input Power Tab The Input Power tab allows you to assign performance monitoring thresholds for the power coming into the wavelength converter module. Table D-375 Field Field Descriptions for the Input Power Tab Description Input Power 1 Value When the Update button is clicked, displays the current module input power.