User Manual

Table Of Contents
40
Cisco Connected Grid 3G Module Installation and Configuration Guide
OL-25991-01
Troubleshooting and Diagnostics
Hardware Information
====================
Modem Firmware Version = T1_0_3_2AP R361 CNSZXD00000061 2011/04/15 17:40:48
Modem Firmware Built = 04/15/11
Modem Hardware Version = 1.0
International Mobile Subscriber Identity (IMSI) = 345678901
International Mobile Equipment Identity (IMEI) = 357115040054053
Factory Serial Number (FSN) = CC3200115221007
Modem status = Online
Current Modem Temperature = 0 deg C
Current Temperature State = Normal
Profile Information
====================
* - Default profile
<-- Indicates that no profile is present
Data Connection Information
===========================
Data Transmitted = 5616 bytes
Data Received = 9424 bytes
Profile 1, Packet Session Status = ACTIVATED
IP Address = 192.0.2.0
Network Information
===================
Current Service Status = No service, Service Error = None
<-- Indicates no service—not connected to
network
Current Service = Combined
Packet Service = None
Packet Session Status = Inactive
Current Roaming Status = Home
Network Selection Mode = Automatic
Country = USA, Network = Cinglr
Mobile Country Code (MCC) = 310
Mobile Network Code (MNC) = 380
Location Area Code (LAC) = 6042
Routing Area Code (RAC) = 255
Cell ID = 0
Primary Scrambling Code = 0
PLMN Selection = Automatic
Radio Information
=================
Current Band = None, Channel Number = 0
Current RSSI = -110 dBm
<-- Indicates either no antenna or bad antenna, or out of network
Band Information
================
Number of bands: 5
Band 1: GSM EGSM DCS
Band 2: Unknown Band Group
Band 3: GSM ALL
Band 4: Unknown Band Group
Band 5: AUTO BAND