User's Manual
DEC. 2011—EFT REVIEW DRAFT—CISCO CONFIDENTIAL
4-3
Cisco 1240 Connected Grid Router Hardware Installation Guide
OL-26223-01
Chapter 4 Opening the Router Chassis
Opening the Router Door
• When opening the door, alternate loosening screws on each side of the chassis, in the order shown
in
Figure 4-1, to evenly release the door pressure.
• When closing the door, do not tighten the screws on the hinge-side of the door first. Tightening the
screws on the hinge-side first can place too much pressure on the door hinges.
Figure 4-2 Recommended Order of Loosening and Tightening Screws
Opening the Door
Step 1 To open the door, use a box-end or socket wrench to loosen all six captive screws in the order shown in
Figure 4-1.
Note The screws cannot be removed from the door. Figure 4-3 is a detailed view of a captive screw.
Step 2 After all six screws are loose, swing the door open on the left-side hinges, as shown in Figure 4-4.
Caution The door gasket creates a seal when the door is closed, so the door might open suddenly when the last
screw is loosened.
3
2 4
5
6
1