User's Manual

Ripwave Base Station I&C Guide Navini Networks, Inc.
190 Part #40-00047-00 Rev D v1.0
February 28, 2003
Figure H2: Example of 120° of an Omni Site
Acceptable Criteria
In order to evaluate the test results, several criteria are reviewed. These criteria are valid for both
LOS and NLOS measurements.
Processed Sync Signal Strength: For a given test location, +/- 2 dB variation during FTP
Absolute Sync Signal Strength - Processed Sync Signal Strength: <= to 2 dB variation during
FTP
SNR values consistent during the FTP for all carriers used:
a. QPSK: >= 11 dB
b. 8 PSK: >= 16 dB
c. QAM 16: >= 19 dB
UL and DL Packet Error Rates (PER) <= 1%. This will vary according to interference levels,
but may not render the system inoperable.
Uplink Beamforming Gain: <= 21 dB and >= 16 dB. Perform a comparison of UL and DL,
Beamforming Gain differences should be <= 3 dB.