User's Manual

Navini Networks, Inc. Ripwave Base Station I&C Guide
Part #40-00047-00 Rev D v1.0 191
February 28, 2003
CPE Transmit Power < 25 dBm; BTS Transmit Power < 0 dBm per code channel with power
control
Sync vs. Data Rate:
Absolute Sync (dBm)
UL Data Rate (Mbps) DL Data Rate (Mbps)
(A) -55 to -70 0.6 to 1.0 1.5 to 2.0
(B) -70 to -85 0.5 to 1.0 1.2 to 2.0
(C) -85 to -95 0.10 to 0.5 0.3 to 1.0
Process
The recommended process for performing the Location (FTP) tests is described below.
First
: Verify that a single CPE transmits and receives data at expected rates, as indicated
previously.
Second
: Verify that multiple CPE’s simultaneously transmit and receive data at acceptable rates,
and the parameters listed above are being met. NOTE: The exact number of CPE’s is determined
by field conditions. The minimum is two.
Third
: Verify operation at the full range of the system*. Include LOS Location Tests at cell
edges. The height of CPE and uplink and downlink data rates are recorded for each site. Data
rates are to be compared with expected results, as seen in the last item (Sync vs. Data Rate) of
Acceptance Criteria. For example:
*2.6 GHz : ~12 Km
*2.4 GHz: ~ 3 Km
Equipment Required
Laptop computer
GPS with serial cable
FTP/Location Test Tool application
BTS Beamforming diagnostic tool
CPE
CPE power supply
DC to AC power converter
Ethernet Cable