User's Manual
Ripwave Base Station I&C Guide Navini Networks, Inc.
96 Part #40-00047-00 Rev D v1.0
February 28, 2003
Calibrate the Base Station
Calibrating the Base Station detects the phase differential between the antennas and matches the
output power across all antennas in the RFS. The calibration procedure must be performed at
least three times to ensure validity. Ensure that the BTS has been powered on with the power
amplifiers on for at least fifteen minutes to allow them time to warm up and stabilize.
Calibration Procedure
To calibrate the BTS, follow the steps in the procedure below. Refer to the Ripwave
Configuration Guide, as needed.
Step 1. On the Test EMS, click on the Server icon to start the EMS Server.
Step 2. Click on the EMS Configuration icon to start the EMS Client GUI.
Step 3. At the EMS Configuration & Alarm Manager login screen, enter the user name and
password. The defaults are emsAdmin / emsAdmin.
Step 4. Verify that Antenna Power, RX Sensitivity, and Cal Cable Loss values are entered in
the fields in the EMS. NOTE: The Power Splitter Loss was entered when you
performed the RFS configuration earlier
.
Step 5. Click on the BTS that is being installed to select it. Right-click on the highlighted BTS
and select Action > Configure. Refer to Figure 47.
Figure 47: Select BTS
Step 6. Click on Air Interface > Layer 1, and then click Calibrate. In the resulting dialog box
(Figure 48), select FULL CALIBRATION and Calibrate.