User's Manual
Ripwave Base Station I&C Guide Navini Networks, Inc.
54 Part #40-00047-00 Rev D v1.0
February 28, 2003
Connect BTS to Ground Connections
All connections need to be checked before power is applied to the system. At a minimum,
perform the following:
• Ensure continuity across all ground connections.
• Ensure an open connection from the power supply output (positive input to the BTS card
cage) to frame ground.
Connect Chassis Alarms
The chassis contains two connectors that are used to send alarm indications to the BTS when the
BTS is housed in an outdoor enclosure. One of the connectors, labeled “CABINET ALARM”, is
used to trigger alarm conditions that occur within the external chassis. The second connector,
labeled “BBU”, is used to process alarms from a battery backup unit. Refer to
Appendix L for
instructions on connecting the alarms.