Step 10. Perform the calibration function two more times. Ensure each time that the values
remain relatively stable (+/- 3), and that none of the results is zero. After you perform
the second calibration, click on Configure. The Config Layer 1 Data window (Figure
52) shows the data from the second calibration. The values in the main screen from the
Show Config selection are from the first calibration. Compare the values from the two
calibrations to ensure that they are stable, and not equal to zero.
Figure 52: Config Layer 1 Data Window
Step 11. Close the Config Layer 1 Data window. Update the main screen by clicking the Show
Configuration button.