Verify
The example in this section shows the gatekeeper endpoint registration.
To verify the configuration, issue the show gatekeeper endpoint command.
GATEKEEPER ENDPOINT
REGISTRATION
CallSignalAddr Port RASSignalAddr Port Zone Name Type Flags
−−−−−−−−−−−−−− −−−− −−−−−−−−−−−−− −−−− −−−−−−−−− −−−− −−−−−
172.16.13.40 1720 172.16.13.40 50923 gk2 VOIP−GW E164−ID: 1234
H323−ID: 3640
172.16.13.43 1720 172.16.13.43 58400 gk2 VOIP−GW H323−ID: 3660−2
172.16.104.117 1720 172.69.85.90 1719 gk2 TERM E164−ID: 3000
172.16.104.117 1721 172.69.85.90 1739 gk2 TERM E164−ID: 3001
Total number of active registrations=3
Note: The ATA 186 registers as an H.323 terminal (TERM) and not as an H.323 gateway. This is done
deliberately so that only the calls intended for the ATA 186 are sent to it.
Note: You can not have any address in the ATA gateway field. You can not configure the ATA 186 to work
with the gatekeeper as well as the gateway.
Troubleshoot
This section provides information to troubleshoot your configuration.
The ATA 186 does not provide dial tone if it is not successfully registered with the gatekeeper. If the ATA
186 is not registering with the gatekeeper, verify these items:
IP connectivity exists between the ATA 186 and the gatekeeper.
The ATA 186 UID0 and UID1 fields are configured correctly.
If the UID fields are set to 0, the ATA 186 does not attempt to register with the gatekeeper.
At the least, the UID0 field must be a non−zero value, for the ATA 186 to start the
registration process.
If both ATA 186 ports (UID0 and UID1) have non−zero E.164 addresses, the ATA 186
attempts to register with both ports. The ATA 186 does not provide dial tone, even if one of
the ports is unable to register.
The gatekeeper is configured correctly.
If the gatekeeper is configured with a local zone prefix, the E.164 address of the ATA 186
must be included.
If security is configured on the gatekeeper, the ATA 186 must be configured accordingly.
In addition, verify that the UseSIP field is set to 0. This is necessary to configure the ATA 186 in H.323
mode. If the UseSIP field is set to 1, the ATA 186 does not send the registration request to the gatekeeper.
Troubleshoot the Gatekeeper
When security is configured, issue the debug aaa authentication command.
If no security is configured, issue the debug ras command.