Ta b le 2-1 Power and Alarm Connector Labels
Label Description
V Positive DC power connection
RT Return DC power connection
A Each alarm connection is labeled identicall
y—this means each conn
ection can be an
Alarm in’ orAlarm reference’ signal, provided the second alarm connection
provides the other alarm signal.
29/OCT/2014 REVIEW DRAFT — CISCO CONFIDENTIAL
2-21
Cisco IR500 Series WPAN Gateway and Range Extender Installation and Configuration Guide
Chapter 2 Installation
Connecting the Protective Ground and Power
Step 3 Measure two strands of twisted-pair copper wire (18-to-20 AWG) long enough to connect to the DC
power source.
Step 4 Using an 18-gauge wire-stripping tool, strip each of the two twisted pair wires coming from each
DC-input power source to 0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm). Do not strip more than 0.27 inch
(6.8 mm) of insulation from the wire. Stripping more than the recommended amount of wire can leave
exposed wire from the power connector after installation.
Figure 2-12 Stripping the Power Connection Wire
97489
1
1 0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)
Step 5 Remove the two captive screws that attach the power and alarm connector to the WPAN gateway, and
remove the connector. See Figure 2-13.