Assembly Instructions

Navini Networks, Inc. Ripwave Base Station I&C Guide
Part #40-00047-00 Rev F v1.0 (TTA) 199
October 23, 2003
Figure O16: Transmit Side
Step 4. Set the test box to RFS and TX.
Step 5. From the Delta marker established during the calibration, record the insertion loss dB
level.
Step 6. Perform Step 5 for all eight antennas.
Step 7. Set the Signal Generator output level to 0 dB and recalibrate the test equipment.
Step 8. Configure the test equipment as shown in Figure O17.
?? Signal Generator to the Cal Port
?? Spectrum Analyzer to the test equipment port of the test box.
?? Test box RFC/RFS port to the antenna
Figure O17: Receive Side
Signal Generator
Spectrum Analyzer
Test cable
RFS
1234 5678
c
a
l
Test cable
Test cable
Signal Generator
Spectrum Analyzer
Test cable
RFS
1234 5678
c
a
l
Test cable
Test cable