Assembly Instructions

Ripwave Base Station I&C Guide Navini Networks, Inc.
184 Part #40-00047-00 Rev F v1.0 (TTA)
October 23, 2003
Equipment Required
?? Signal Generator - Agilent 8648C, or suitable alternative, tunable to the RFS center
frequency
?? Spectrum Analyzer - Agilent E4402B, or equivalent
?? Signal Generator cable and Spectrum Analyzer cable Gender can be changed using a
barrel connector
?? Male and Female barrel connectors for Signal Generator cable and Spectrum Analyzer
cable connections
?? Power/data test cable
?? Navini RFS Test Box
Equipment Settings
Spectrum Analyzer:
?? Span 5 MHz
?? RBW 100 KHz
?? VBW 100 KHz
?? Sweep Time Auto
?? Frequency (Provided in Table O4)
Signal Generator:
?? Amplitude 0 dB
?? Frequency (Provided in Table O4)
Test Setup
When performing each type of sweep, the sweep has to be performed at certain frequency
intervals (Table C5). Perform the complete test at the first frequency. Go to the next frequency
and recalibrate the test setup. Perform the complete test again. Do the same for the third
frequency. Refer to Figure O2.
Table O4: Sweep Frequencies
System Sweep 1 Sweep 2 Sweep 3
2.3 GHz High band 2348.25 2352.50 2357.50
2.3 GHz Low band 2307.50 2312.50 2316.75
2.4 GHz 2400.00 2440.00 2473.50
2.5 GHz 2500.00 2548.00 2596.00
2.6 GHz 2602.00 2620.00 2641.00
2.6 GHz EFGH 2602.00 2641.00 2683.00