Field Name Values Description
Alpha Value 2 Used to specify the number of consecutive valid ICP
cells to be detected before moving to the IMA hunt state
from the IMA sync state.
Gamma Value 1 Used to specify the number of consecutive valid ICP
cells to be detected before moving to the IMA sync state
from the IMA pre-sync state.
Index IMA group 2 IMA Group 1 or 2. Unique sequence number of the IMA
group.
Min Num Tx Links 1 Minimum number of Transmission links that have to be
active for the IMA group to be active.
Ne Tx Clk Mode ITC Near-end Transmit clock mode.
Tx Frame Length M128 Length of IMA frame being transmitted. It is defined as
M consecutive cells.
Beta Value 2 Used to specify the number of consecutive ICP cells with
errors to be detected before moving to the IMA hunt state
from the IMA sync state.
Add T1s to IMA Groups
IMA Group T1s Associated With this IMA Group Notes
IMA 1
IMA 2
ATM
Field Name Values Description
If Index T1-1 (first T1 ID) Interface (IF) Index associated with this ATM interface.
Max Vccs 1001 Maximum Virtual Channel Circuits for this interface.
Max Active Vci Bits 9 The number of bits for Virtual Channel Identifier (VCI).
Determines the maximum VCI value allowed for this
interface. The Max Value is calculated by 2^ (max active
vci bits).
Max Vpcs 0 Maximum Virtual Private Circuits for this interface.
Max Active Vpi Bits 3 The number of bits for Virtual Private Identifier.
Determines the maximum VPI value allowed for this
interface. The max value is calculated by 2^ (max active
vpi bits).