Connection Diagram

Ripwave Base Station I&C Guide Navini Networks, Inc.
168 Part #40-00047-00 Rev F v1.0 (TTA)
October 23, 2003
Table L2: Cable Attenuation in dB per 100 Feet
Cable Type
2 ¼?
LDF
12-50
1 5/8?
LDF 7-
50A
LMR
1700
1 ¼?
LDF
6-
50A
LMR
1200
7/8?
LDF
5-
50A
LMR
900
5/8?
LDF
4.5-
50A
½ ?
LDF
4-
50A
LMR
600
½ ?
Super
flex
FSJ
4-
50B
LMR
500
3/8?
LDF
2-
50A
LMR
400
Frequency/Size
2.350 1.980
1.670
1.550
1.200
1.090
0.870
0.865 0.630
0.590
0.520
0.500
0.440
0.405
2000 MHz
0.994 1.11
1.5
1.42
1.99
1.82
2.64
2.27 3.25
3.9
5.09
4.84
5.17
6
2400 MHz
N/A 1.24
1.7
1.5
2.2
2.02
2.9
2.52 3.63
4.3
5.67
5.4
5.67
6.6
2500 MHz
N/A 1.27
1.71
1.53
2.26
2.07
3
2.58 3.70
4.42
5.8
5.48 5.79 6.8
2600 MHz
N/A 1.3
1.8
1.57
2.3
2.12
3.1
2.64 3.78
4.5
5.94
5.6
5.91
6.9
Weight lbs/ft
1.22 0.82
0.74
0.63
0.45
0.33
0.27
0.15 0.15
0.13
0.14
0.1
0.08
0.07
Bend Radius (inches)
24 20
13.5
15
6.5
10
3
8 5
1.5
3
1.25
3.75
1
Table L3: 2.4 GHz TTA BTA Max Power and Frequency Range Supported
Max Power Frequency Range Supported
Omni 17.5 dBm
US
Sector 16 dBm
Omni 24 dBm
ETSI
Sector 18 dBm
2.400 to 2.483 GHz
Table L4: 2.4 GHz TTA BTA Cable Loss and Corresponding Cable Length
Cable
Loss
Calculated
Length of RG6
Bundled Cable
Engineering Notes
Min 5 dB 40 ft (12 m)
US
(Omni & Sector)
Max
(1)
20 dB 180 ft (55 m)
For a cable loss of more than 15 dB,
Adjacent Channel Power degradation
will occur.
At 20 dB of cable loss a minimum
ACP degradation of 3dB will occur
Min 5 dB 40 ft (12 m)
Omni
Max
(2)
20 dB 180 ft (55 m)
Min 5 dB 40 ft (12 m)
ETSI
Sector
Max
(1)
20 dB 180 ft (55 m)
For a cable loss of more than 15 dB,
Adjacent Channel Power degradation
will be dominated by RFC.
At 20 dB of cable loss RFC SNR will
be approaching 30 dB