Regulatory Information
FCC Notice
WARNING! This device is a Radio Frequency transmitter. It is required to comply with
FCC RF exposure requirements for transmitting devices. A minimum separation distance
of 2 meter or more must be maintained between the antenna and all persons during device
operations to ensure compliance with the FCC’s rules for Radio Frequency Exposure. If
this minimum distance cannot be maintained, exposure to RF levels that exceed the
FCC’s limits may result.
INFORMATION TO USER
This device has been authorized as a radio frequency transmitter under the appropriate
rules of the Federal Communications Commission. Any changes or modifications not
expressly approved by Navini Networks could void the user’s authority to operate the
equipment.
UL & NEC/CEC Regulations
1. The Ripwave BTS must be installed in accordance with NEC/CEC Articles 800/810/830.
2. As a minimum, all DC power leads and bonding/grounding straps shall be 6 AWG
copper conductors.
3. GPS, RF, and power/data cables in excess of 140 feet in length must have protective
devices installed that are UL listed to UL 492, UL497A or UL497B, UL497C, and
UL1449.
4. If lightning protection is required, the device(s) must comply with UL497.
5. Power supplies should be UL listed to UL60950 or UL60950-1 and have earthed SELV
output.
6. Ethernet connections require a UL497B listed protection device to be installed between
the BTS and the first network device. T1 connections must be routed from the BTS
through a UL497 listed protection device at the demarcation point.
7. T1 interconnect cables between the BTS and demarcation point must be a minimum of
#26 AWG wire, in accordance with NEC/CEC standards.
8. All power and ground conductors must be mechanically supported to avoid strain of the
wires and connection points.
9. A UL listed disconnect device, such as a circuit breaker or fuse, must be installed
between the power supply and BTS chassis connections.
10. Power-interconnect wires between the power supply/recitifier and the BTS Digital
chassis must have heat shrink tubing applied over the barrel of the terminal lugs after
crimping the wire. A picture is provided in the “Installation” section of this manual.
11. If it is necessary to replace a fuse on a CHP, CC or PA board, a fuse of the same type and
with the same rating must be used to insure continued protection against risk of fire.