Installing the Cisco LoRaWAN Interface Module
Mounting the Device
Figure 2 Mounting Bracket for Wall or Pole Mounting
2. Use four customer-supplied screws and optional screw-anchors to attach the mounting plate to the mounting
surface.
3. If necessary, use suitable screw anchors and an exterior-grade plywood backboard to mount the Cisco LoRaWAN
Interface Module to stucco, cement or drywall.
4. Screw an M6 x12 mm bolt into each of the four support bolt holes on the back of the Cisco LoRaWAN Interface
Module. Do not screw the bolt all the way in; leave approximately a 1/8” (3.3 mm) space.
5. Position the four bolts on the Cisco LoRaWAN Interface Module into the keyhole slots on the mounting bracket.
6. Slide the Cisco LoRaWAN Interface Module down to sit securely in the quick mount slots.
7. Using a 10mm wrench, secure the Cisco LoRaWAN Interface Module to the bracket by tightening the bolts to the
bracket; torque to 40 in-lbs (4.52 N-m).
8. Continue with Grounding the Device.
Pole Mounting With the Mounting Kit
The mounting kit contains a mounting bracket for wall mounting or pole mounting. This kit can be used to install the Cisco
LoRaWAN Interface Module on a pole. It supports metal, wood or fiberglass poles from 2 to 8 inches in diameter.
1 Quick Mount Keyhole Slots (for the Cisco
LoRa Interface use)
2 Mounting Slots (used with the band clamps)
3 Bracket Mount Holes (use bolts up to 1/4" or 6 mm in diameter)