User Manual
HLD-H/W WIBS
9
Cisco Systems, Inc. Confidential
Configuration Specifications Comments
T1/E1 Trunk FCC part 68
Intrusion Resistance BELLCORE GR-487
Shotgun Resistance BELLCORE GR-487
Climatic Environment
Internal Heat Load 120 watts Maximum
Ambient Air Temperature
-20
0
C ~ +46
0
C
Solar Load 70W/ft
2
Ambient Humidity 5% - 95 %
Altitude TBD
Table 2.5-1 Environmental Specifications
4.6 Reliability Specifications
4.6.1 Mean Time Between Critical Failures(MTBCF)
The MTBCF shall be longer than 50,000 hours.
4.6.2 Enclosure Material
The aluminum for the WIBS enclosure shall have better than or equal to the quality of aluminum
6082 in accordance with standard QQ-A-2501/II TEMP T6.
4.6.3 Grounding Requirement
Grounding and electric safety of the WIBS shall comply with the requirements of TR-NWT-001089.
4.6.4 Alarm Requirements
The WIBS shall monitor alarms and status, and report them to the upper level controller. Followings
are some alarms:
l AC power failure
l DC power failure
l major control processors failure
l High temperature
l Low Battery Alarm
5. Installation
• WIBS System having a characteristic such as covering small area of dense population can
be installed at any place where customers want to install.
• The system can be mounted on the stable standing type structure or sturdy object inside
building or outside wall.
• Customer should contact customer service center to install WIBS system properly.
• An only qualified person has to install WIBS system
• No responsibility is required for manufacturer regarding any injury or damage causing from
inappropriate installation.