user manual
3-70
Cisco 7600 Series Router MIB Specifications Guide
OL-4077-07
Chapter 3 Cisco 7600 MIB Specifications
CISCO-ENTITY-ALARM-MIB
–
Minor—Used for troubles that do not have a serious effect on service to customers or for alarms
in hardware that are not essential to the operation of the system.
–
Info—Notification about a condition that could lead to an impending problem or notification of
an event that improves operation.
The syntax values are: critical(1), major(2), minor(3), info(4)
• Alarm description text—Specifies a readable message describing the alarm.
• Alarm type—Identifies the type of alarm that is generated. An arbitrary integer value that uniquely
identifies an event relative to a physical entity in the Cisco 7600 router. Values 0 through 255.
Table 3-10 lists the alarm descriptions and severity levels for the Cisco 7600 router FlexWAN PA T3/E3
ports.
Table 3-11 lists the alarm descriptions and severity levels for the Cisco 7600 router ATM and packet over
SONET ports.
Table 3-10 Alarms Supported for Cisco 7600 Router FlexWAN PA T3/E3 Ports
Physical Entity ceAlarmDescrVendorType
ceAlarmDescr
Severity ceAlarmDescrText
FlexWAN PA T3/3E
ports
cevPortT3
cevPortE3
cevPortDsE3Atm
major Transmitter is sending remote
alarm
major Transmitter is sending AIS
major Receiver has loss of signal
major Receiver is receiving AIS
major Receiver has loss of frame
major Receiver has remote alarm
major Receiver has idle signal
major Other failure
major Physical port link down
info Physical port administrative
state down
Table 3-11 Alarms Supported for Cisco 7600 Router ATM and POS Ports
Physical Entity ceAlarmDescrVendorType
ceAlarmDescr
Severity ceAlarmDescrText
ATM and POS ports cevPortATM
cevPortPOS
cevPortChSonet
critical Section loss of signal failure
critical Section loss of frame failure
critical Section out of frame alignment
minor J0 trace byte mismatch
minor Section bit interleaved parity
major Line alarm indication signal