Installation Manual

CiscouBR7200 Series Universal Broadband Router Wireless Modem Card and Subsystem Installation and Configuration 71
metrics alarm (link metrics thresholds)
ALPHA DRAFT - CISCO CONFIDENTIAL
Syntax Description
Example
The following example will configure the link so that:
If more than 3 codeword errors are detected per second, that second will be treated as an errored
second.
If more than 30 codeword errors are detected in one second, that second will be flagged as a
degraded second.
If more than 150 codeword errors are detected in one second, that second will be flagged as a
severely errored second.
If more than 4 codeword severely errored seconds are detected in sequence, that sequence is
flagged as a 1 codeword severely errored second.
WMCS01(boot)(config-if)# radio metrics Alarm CWErr 3 30 150 4
The following example will configure the link alarms so that:
If the link has codeword errors 66.67% of the time in one hour, an alarm will be generated.
If the link was severely errored more than 10% of the time, an alarm will be generated.
ESThresh Specifies the number of codeword errors that must be detected within a one second
interval for that second to be treated as a Codeword Errored Second.
DSThresh Specifies the number of codeword errors that must be detected within a one second
interval for that second to be treated as a Codeword Degraded Second.
SESThresh Specifies the number of codeword errors that must be detected within a one second
interval for that second to be treated as a Codeword Severely Errored Second.
CSESThresh Specifies the number of consecutive codeword severely errored seconds that must be
detected for the sequence to be treated as one codeword consecutive severely errored
second (CSES).
ESLimit Specifies the number of codeword errored seconds that should be detected within the
specified time period (one operational hour or 24 operational hours), after which the
ESLimit minor alarm will be generated.
SESLimit Specifies the number of codeword severely errored seconds that should be detected
within the specified time period (one operational hour or 24 operational hours), after
which the SESLimit minor alarm will be generated.
CSESLimit Specifies the number of codeword consecutively severely errored seconds that should be
detected within the specified time period (one operational hour or 24 operational hours),
after which the CSESLimit minor alarm will be generated.
DMLimit Specifies the number of codeword degraded minutes that should be detected within the
specified period (one operational hour or 24 operational hours), after which the
DMLimit minor error alarm will be generated.
slot Positive integer representing the CiscouBR7200 series slot number.
port Positive integer representing the port number on that slot.