DLP- A509 Provision CE-1000-4 Ethernet Ports
DLP-A509 Provision CE-1000-4 Ethernet Ports
Note You can provision SONET contiguous concatenated (CCAT) or virtual concatenated (VCAT) circuits for
the CE-1000-4 before or after provisioning the card’s Ethernet ports and/or packet-over-SONET (POS)
ports. See the “NTP-A257 Create an Automatically Routed Optical Circuit” procedure on page 6-38 or
the “NTP-A264 Create an Automatically Routed VCAT Circuit” procedure on page 6-82, as needed.
Step 1 In node view, double-click the CE-1000-4 card graphic to open the card.
Step 2 Click the Provisioning > Ether Ports tabs.
Step 3 For each CE-1000-4 port, provision the following parameters:
• Port Name— If you want to label the port, enter the port name.
• Admin State— Select the service state for the port. See the “DLP-A214 Change the Service State
for a Port” task on page 19-9 for more information.
• Flow Control— Select the flow control for the port. Possible values are None, Symmetrical, and
Pass Through.
• Auto Negotiation— Click this check box to enable autonegotiation on the port (default). If you do
not want to enable autonegotiation control, uncheck the box.
• MTU— If you want to permit the acceptance of jumbo size Ethernet frames, choose 10004(default).
If you do not want to permit jumbo size Ethernet frames, choose 1548.
• Watermark— Select the flow control watermark for the port. To provision the Low Latency flow
control watermark, choose Low Latency from the drop-down list. The Flow Ctrl Lo and Flow Ctrl
Hi values change. To provision a Custom flow control watermark, choose Custom from the
drop-down list. Enter values in the Flow Ctrl Hi and Flow Ctrl Lo columns. The Flow Ctrl Lo value
has a valid range from 1 to 510 and the Flow Ctrl Hi value has a valid range from 2 to 511. The Flow
Ctrl Lo value must be lower than the Flow Ctrl Hi value.
Step 4 Click Apply.
Step 5 Refresh the Ethernet statistics:
a. Click the Performance > Ether Ports > Statistics tabs.
b. Click Refresh.
Note Reprovisioning an Ethernet port on the CE-1000-4 card does not reset the Ethernet statistics for
that port.
Step 6 Return to your originating procedure (NTP).