System Manual
Table Of Contents
- Cisco 860 Series, Cisco 880 Series, and Cisco 890 Series Integrated Services Routers Hardware Installation Guide
- Preface
- Product Overview
- General Description
- Cisco 860 Series ISRs
- Cisco 860VAE Series ISRs
- Cisco 880 Series ISRs
- Cisco 890 Series ISRs
- Hardware Features
- Installing the Router
- Connecting the Router
- Preparing to Connect the Router
- Connecting a PC, Server, or Workstation
- Connecting a Phone
- Connecting an External Ethernet Switch
- Connecting the V.92 modem Port
- Connecting a Terminal or PC to the Console Port
- Connecting a Modem to the Auxiliary Port
- Connecting the 3G Card
- Installing the 3G Adapter for Extended Cable/Antenna
- Connecting a Data BRI Port
- Connecting an FE Line to an FE WAN Port
- Connecting an GE Line to an GE WAN Port
- Connecting an xDSL Line
- Connecting Power over Ethernet
- Connecting the AC Adapter
- Connecting an FXS Line
- Connecting an FXO Line
- Connecting a Voice ISDN BRI Line
- Connecting a Small-form-factor Pluggable Module
- Verifying Connections
- Initial Configuration
- Technical Specifications
- Router Specifications
- Wireless Access Point
- FE and GE Port Pinouts
- Console and Auxiliary Port Connector Pinouts
- FXS and FXO Port Connector Pinouts
- VDSL2 Port Connector Pinouts
- ADSL2+ Port Connector Pinouts
- V.92 Port Connector Pinouts
- G.SHDSL Port Connector Pinouts
- Data BRI Port Connector Pinouts
- Voice ISDN BRI Interface Pin Numbers and Functions
- SFP Port Connector Pinouts
- Cable Specifications
3-29
Cisco 860 Series, Cisco 880 Series, and Cisco 890 Series Integrated Services Routers Hardware Installation Guide
OL-16193-07
Chapter 3 Connecting the Router
Connecting an FXS Line
Step 3
Snap the latches into the holes on either side of the power connector. See Figure 3-27.
Figure 3-27 Power Lock Clip Latched Into the Holes on Either Side of the Power Connector
Connecting an FXS Line
Use a standard straight-through RJ-11 modular telephone cable to connect a Foreign Exchange Service
(FXS) port to a telephone or fax machine.
Warning
This equipment contains a ring signal generator (ringer), which is a source of hazardous voltage.
Do not touch the RJ-11 (phone) port wires (conductors), the conductors of a cable connected to
the RJ-11 port, or the associated circuit-board when the ringer is active. The ringer is activated
by an incoming call.
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit
is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When
detaching cables, detach the end away from the unit first.
Statement 1026
Warning
For connections outside the building where the equipment is installed, the following ports must
be connected through an approved network termination unit with integral circuit protection:
FXS.
1 Power lock clip 3 Power adapter
2 Power cord 4 AC plug
270800
1
2
4
3