User manual

78-6643-01 09/27/99 Cisco 6100 Series System Cables 3
Cisco 6100 Series User Guide 3-17
3.4 DOH Configuration Cables
In a DOH configuration, use only designated cables to connect the MC, LCC, PSC, and MDF. This
section provides tables and illustrations for the following:
Basic component cables
PSC to MDF cables
Note Some chassis connectors in the cabling diagrams are not used because they are specific to one
of the other configurations of the Cisco 6100 Series system or because they are reserved for
future use.
3.4.1 Basic DOH Component Cables
You can use one-to-one cables to connect the MC, LCC, and PSC for systems using dual-port CAP
ATU-C modules. Table 3-9 lists the backplane connectors and the part numbers for the basic
one-to-one cables connecting the MC, LCC, and PSC in a DOH configuration.
Note When you use the one-to-one cable, see Table C-7 on page C-23 for port
mapping information.
Table 3-9 Connectors and Part Numbers for One-to-One Cables—MC, LCC, and PSC
Connections
Backplane Connector
Cisco Part Number
NetSpeed Part
NumberKit Subassembly
MC LCC
J45 J25 CAB-61-011 72-1627-01 4100-014-01
J46 J26 CAB-61-011 72-1626-01 4100-014-02
J47 J29 CAB-61-011 72-1641-01 4100-030-02
LCC LCC
J27 J25 CAB-61-012 72-1625-01 4100-014-03
J28 J26 CAB-61-012 72-1625-01 4100-014-03
J30 J29 CAB-61-012 72-1602-01 4100-030-01
LCC PSC
J23 J6 CAB-61-013 72-1619-01 4100-016-01
J22 J5 CAB-61-013 72-1619-01 4100-016-01
J24 J4 CAB-61-013 72-1619-01 4100-016-01
J21 J3 CAB-61-013 72-1619-01 4100-016-01