User's Manual
Table Of Contents
- Cisco WRP500 Administration Guide
- Contents
- 1
- WRP500 Features and Benefits
- Deployment Models
- Local Area Network Guidelines
- Special Requirements for Voice Deployments
- WRP500 Maintenance Operations
- Remote Provisioning
- Configure NAT Mapping
- Configure NAT Mapping with a Static IP Address
- Step 1 Log in as administrator.
- Step 2 Under the Voice menu, click SIP.
- Step 3 In the NAT Support Parameters section, enter the following settings:
- Step 4 Under the Voice menu, click Line 1 or Line 2 to choose the line interface that you want to modify.
- Step 5 In the NAT Settings section, enter the following settings:
- Step 6 Click Save Settings.
- Configure NAT Mapping with STUN
- Step 1 Log in as administrator.
- Step 2 Under the Voice menu, click SIP.
- Step 3 In the NAT Support Parameters section, enter the following settings:
- Step 4 Under the Voice menu, click Line 1 or Line 2 to choose the line interface that you want to modify.
- Step 5 In the NAT Settings section, enter the following settings:
- Step 6 Click Save Settings.
- Determine Whether the Router Uses Symmetric or Asymmetric NAT
- Step 1 Make sure you do not have firewall running on your computer that could block the syslog port (port 514 by default).
- Step 2 Log in as administrator.
- Step 3 To enable debugging, complete the following tasks:
- Step 4 To collect information about the type of NAT your router is using, complete the following tasks:
- Step 5 To enable SIP signaling, complete the following task:
- Step 6 Click Submit.
- Step 7 View the syslog messages to determine whether your network uses symmetric NAT. Look for a warning header in the REGISTER messages, such as Warning: 399 spa "Full Cone NAT Detected.”
- Configure NAT Mapping with a Static IP Address
- Firewalls and SIP
- Configure SIP Timer Values
- Analog Telephone Adapter Operations
- ATA Software Features
- Register to the Service Provider
- Step 1 Log in as administrator.
- Step 2 Under the Voice menu, click Line 1 or Line 2 to choose the line interface that you want to modify.
- Step 3 In the Proxy and Registration section, enter the Proxy.
- Step 4 In the Subscriber Information section, enter the User ID and Password.
- Step 5 Click Submit. The devices reboot.
- Step 6 To verify your progress, perform the following tasks:
- Manage Caller ID Service
- Optimize Fax Completion Rates
- Step 1 Ensure that you have enough bandwidth for the uplink and the downlink.
- Step 2 To optimize G.711 fallback fax completion rates, set the following on the Line tab of your ATA device:
- Step 3 If you are using a Cisco media gateway for PSTN termination, disable T.38 (fax relay) and enable fax using modem passthrough.
- Step 4 Enable T.38 fax on the WRP500 by configuring the following parameter on the Line tab for the FXS port to which the FAX machine is connected:
- Step 5 If you are using a Cisco media gateway use the following settings:
- Fax Troubleshooting
- Step 1 Verify that your fax machine is set to a speed between 7200 and 14400.
- Step 2 Send a test fax in a controlled environment between two ATAs.
- Step 3 Determine the success rate.
- Step 4 Monitor the network and record the following statistics:
- Step 5 If faxes fail consistently, capture a copy of the voice settings by selecting Save As > Web page, complete from the administration web server page. You can send this configuration file to Technical Support.
- Step 7 Identify the type of fax machine connected to the ATA device.
- Step 8 Contact technical support:
- Silence Suppression and Comfort Noise Generation
- Configure Dial Plans
- About Dial Plans
- Edit Dial Plans
- Enter the Line Interface Dial Plan
- Step 1 Start Internet Explorer, connect to the Configuration Utility, choose Voice > Admin Login. If prompted, enter the administrative login provided by the Service Provider. (The default username and password are both admin.)rovided by your Service...
- Step 2 Under the Voice menu, click Line 1 or Line 2, depending on the line interface that you want to configure.
- Step 3 Scroll down to the Dial Plan section.
- Step 4 Enter the digit sequences in the Dial Plan field. For more information, see “About Dial Plans,” on page 11.
- Step 5 Click Submit.
- Reset the Control Timers
- Step 1 Start Internet Explorer, connect to the Configuration Utility, choose Voice > Admin Login. If prompted, enter the administrative login provided by the Service Provider. (The default username and password are both admin.)rovided by your Service...
- Step 2 Under the Voice menu, click Regional.
- Step 3 Scroll down to the Control Timer Values section.
- Step 4 Enter the desired values in the Interdigit Long Timer field and the Interdigit Short Timer field. Refer to the definitions at the beginning of this section.
- Enter the Line Interface Dial Plan
- Secure Call Implementation
- Info page
- System page
- SIP page
- Regional page
- Line page
- Line Enable section
- Streaming Audio Server (SAS) section
- NAT Settings section
- Network Settings section
- SIP Settings section
- Proxy and Registration section
- Subscriber Information section
- Supplementary Service Subscription section
- Audio Configuration section
- Dial Plan section
- FXS Port Polarity Configuration section
- User page
- Setup
- Wireless Configuration
- Security
- Access Restrictions
- Applications and Gaming
- Administration
- Status
REVIEW DRAFT #1—CISCO CONFIDENTIAL
3-5
Cisco WRP500 Administration Guide
Chapter 3 Configure Voice Services
ATA Software Features
Configurable Dial Plan
with Interdigit Timers
The WRP500 has three configurable interdigit timers:
• Initial timeout (T)—Signals that the handset is off the hook and
that no digit has been pressed yet.
• Long timeout (L)—Signals the end of a dial string; that is, no more
digits are expected.
• Short timeout (S)—Used between digits; that is after a digit is
pressed a short timeout prevents the digit from being recognized a
second time.
See “Configure Dial Plans,” on page 10 for more information.
Polarity Control The WRP500 allows the polarity to be set when a call is connected and
when a call is disconnected. This feature is required to support some
pay phone system and answering machines. Polarity Control is
configured in the Line and PSTN Line tabs. See Appendix A,
“Advanced Voice Fields.”
Calling Party Control Calling Party Control (CPC) signals to the called party equipment that
the calling party has hung up during a connected call by removing the
voltage between the tip and ring momentarily. This feature is useful for
auto-answer equipment, which then knows when to disengage. CPC is
configured in the Regional, Line, and PSTN Line tabs. See
Appendix A, “Advanced Voice Fields.”
Syslog and Debug
Server Records
Syslog and Debug Sever Records log more details than Report
Generation and Event Logging. Using the configuration parameters,
the WRP500 allows you to select which type of activity/events should
be logged. Syslog and Debug Server allow the information captured to
be sent to a Syslog Server. Syslog and Debug Server Records are
configured in the System, Line, and PSTN Line tabs. See Appendix A,
“Advanced Voice Fields.”
SIP Over TLS The WRP500 allows the use of SIP over Transport Layer Security
(TLS). SIP over TLS is designed to eliminate the possibility of
malicious activity by encrypting the SIP messages of the service
provider and the end user. SIP over TLS relies on the widely-deployed
and standardized TLS protocol. SIP Over TLS encrypts only the
signaling messages and not the media. A separate secure protocol such
as Secure Real-Time Transport Protocol (SRTP) can be used to encrypt
voice packets. SIP over TLS is configured in the SIP Transport
parameter configured in the Line tab(s). See Appendix A, “Advanced
Vo i c e F i e l d s .”
Feature Description