Cisco Catalyst 4900M Switch Installation Guide September 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.
THE SPECIFICATIONS AND INFORMA TION REGARDING TH E PRODUCT S IN TH IS MA NUAL A RE SUBJECT TO CH ANGE WITHOU T NOT ICE. AL L STAT EM ENT S, INFORMA TIO N, AND RECOM MEN DATIONS IN THIS MANUA L ARE BEL IE VED T O BE ACCURATE BU T ARE PRESE NTE D WIT HOUT WA RRAN TY OF AN Y KIN D, E XPRESS OR IMPLIED. USE RS MUST T AKE F ULL RE SPONSIBILITY FOR TH EIR APPL ICAT ION O F ANY PRODUCT S.
C ON TE N TS Preface vii Audience vii Organization vii Related Documentation viii Hardware Documents viii Software Documentation ix Cisco IOS Documentation ix Conventions x Statement 1071—Warning Definition xi Obtaining Documentation and Submitting a Service Request C H A PT E R 1 Product Overview xvi 1-1 Catalyst 4900M Switch Chassis 1-1 Catalyst 4900M Switch Chassis Features 1-2 Catalyst 4900M Switch Chassis Physical and Environmental Specifications 1-3 Catalyst 4900M Switch Chassis Rear Pan
Contents EMI Recommendations 2-3 Power Requirements and Heat Dissipation Grounding Requirements Site Planning Checklist 3 Installing the Switch 2-3 2-7 Safety Overview 2-7 Ensuring Safety 2-7 Working Safely with Electricity 2-8 Preventing Electrostatic Discharge Damage C H AP TER 2-9 2-9 3-1 Checking the Contents 3-1 Rack-Mounting the Switch 3-2 Rack-Mounting Guidelines 3-2 Lifting the Chassis Safely 3-3 Required Installation Tools 3-4 Rack-Mounting the Catalyst 4900M Switch Connecting Power to
Conten ts Troubleshooting the Power Supply Contacting Customer Service 4-4 4-4 A PP E N D I X A Specifications A PP E N D I X B Compliance Information and Translated Safety Warnings Console Port A-1 A-1 10/100/1000BASE-T Management Port A-2 Catalyst 4900M Switch Power Supply Specifications A-2 B-1 Translated Safety Warnings B-1 Statement 258—Fan Tray Removal Warning B-2 Statement 1003—DC Power Disconnection B-3 Statement 1004—Installation Instructions B-4 Statement 1006—Chassis Warning for
Contents Statement 8000—Standards Compliance B-40 Statement 2007—EMC Environmental Conditions for Products Installed in the European Union B-42 EMC Class A Notices and Warnings B-42 Statement 257—Class A Notice for Taiwan and Other Traditional Chinese Markets B-42 Statement 340—Class A Warning for CISPR22 B-43 Statement 2017—Class A Notice for FCC B-44 Statement 2021—Class A Notice for Canada B-44 Statement 191—VCCI Class A Warning for Japan B-45 Statement 256—Class A Warning for Hungary B-45 Statement
Preface This preface describes the aud ience, organization, and conventions of the Cisco Ca talyst 4900 M Switch Ins tallation Gu ide and provides in formatio n o n how to obtain related documentatio n. Audience Only train ed and qualified service pers onnel (as d efin ed in IEC6095 0 and AZ/NZS 609 50) sh ould install, replace, or serv ice th e equipment.
Pre face Related Documentation Related Documentation Althoug h th eir Release Notes are un iq ue, the 4 p latforms (Catalyst 4500 , Catalyst 490 0, Catalys t ME 4 900, an d Catalyst 490 0M) us e the same So ftwa re Configuratio n Guide, Command Reference Guide, and S ystem Messag e Guid e. Refer to th e following home pages for addition al information: • Cataly st 4 500 Series Switch Documentation Home • Cataly st 4 900 Series Switch Documentation Home h ttp://www.cisco.
Preface Related Do cumentation Software Documentation Software releas e notes, configuration g uides, comman d references , and system message g uides are availab le at the following URLs: • Catalyst 4500 release no tes are available at: • Catalyst 4900 release no tes are available at: http://www.cisco.com/en/US/p rodu cts/h w/switches/ps43 24/prod_release_ notes_list.html http://www.cisco.com/en/US/p rodu cts/p s6021/p rod_ release_notes_list.
Pre face Related Documentation Conventions This documen t u ses the following co nvention s: Conven tion Description boldface font Commands an d keyword s are in boldface. italic font Arguments for which you sup ply values are in italics. [ ] Elemen ts in sq uare b rackets are o ptional. { x | y| z } Altern ative k eywords are gro uped in b races and separated by vertical bars. [ x |y | z ] Op tional alternative key words are group ed in brackets and sep arated by vertical bars.
Preface Related Do cumentation Warnings use the following conventions: Statement 1071—Warning Definition Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with el ectrical circuitry and be famili ar with standard practices for preventing accidents.
Pre face Related Documentation Warnung WICHTIGE SICHERHEITSHI NWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, di e zu Verlet zungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektri scher Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
Preface Related Do cumentation Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbet e på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanl iga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medf öljer denna anordning.
Pre face Related Documentation Av iso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há ri sco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes.
Preface Related Do cumentation Cisco Catalyst 4900M Switch In stallatio n Guide 78-18350-02 xv
Pre face Related Documentation Obtaining Documentation and Submitting a Service Request For in formatio n o n obtaining documentatio n, su bmitting a service request, and gathering additional in formatio n, see th e mo nthly What’s New in Cisco Product Documentation, which also lists all new and revis ed Cisco technical documentation, at: h ttp://www.cisco.com/en/US/docs/general/whatsnew/whatsn ew.
CH AP T E R 1 Product Overview Revis ed: January 4, 2012 This chap ter describes the Catalyst 4900 M switch and the supported half-card Eth ernet mod ules . The ch apter contains these sectio ns: • Catalyst 4900 M Switch Chassis, p age 1-1 • Catalyst 4900 M Half-Card Mo dules, page 1-8 • Serial Nu mber Locatio n, page 1-14 Catalyst 4900M Switch Chassis The Catalyst 4900M switch is a 2 RU horizo ntal high -performan ce ded icated Ethernet s witch.
Chapter 1 Product Overview Catalyst 4900M Switch Chassis Catalyst 4900M Switch Chassis 232121 Figure 1-1 Catalyst 4900M Switch Chassis Features Tab le 1-1 lists th e features of the Catalyst 4900 M s witch chassis. Table 1-1 Catalyst 4900M Switch Features Feature Description Chas sis 8-p ort fixed configu ration plus 2 half-card module s lo ts Uplin k p orts 8 10-Gigabit ports that suppo rt X2 tran sceivers. By usin g th e Cisco OneX co nverter, the 8-ports also su pport SFP+ trans ceivers.
Chapter 1 Product Overview Catalyst 4900M Switch Chassis Table 1-1 Catalyst 4900M Switch Features (continued) Feature Description Reset switch Th e Reset button is used to restart the switch. Use a p ap er clip o r oth er small, po inted ob ject to p ress the Reset button . Fan tray Variable-speed. Field replaceable. Power sup plies 10 00 W AC-in put and 1 000 W DC-inpu t power supplies are su pported. Note A console cable is not provided as part of the accessory kit.
Chapter 1 Product Overview Catalyst 4900M Switch Chassis Catalyst 4900M Switch Chassis Rear Panel Connections and Features Figure 1 -2 shows th e chass is rear p anel with the major features id entified .
Chapter 1 Product Overview Catalyst 4900M Switch Chassis Front Panel LEDs A set of LEDS on the ch assis front pan el (see Figure 1-3) pro vide visual status for the s witch. Table 1 -3 lists the fron t panel LEDS and their meaning s. Figure 1-3 4 Chassis Front Panel LEDs 1 3 5 1 PS1 LED 2 PS2 LED 3 Fan LED Table 1-3 4 System LED 5 10 Gig port LEDs Front Panel LED Descriptions LED Description System Th e sys tem LED indicates the operating state of the Cataly st 4 900M switch.
Chapter 1 Product Overview Catalyst 4900M Switch Chassis Table 1-3 Front Panel LED Descriptions (continued) LED Description Fan FAN LED indicates the fan tray status . (front and rear) PS1 and PS2 (front) LINK 1. • Green—Fan tray operational. • Red— Fault detected . On e or mo re fans n ot functional. • Off—No p ower to the fan tray. PS1 and the PS2 LEDs indicates the intern al power s upply status. • Off—No p ower to the power supply. • Green—Operational.
Chapter 1 Product Overview Catalyst 4900M Switch Chassis Catalyst 4900M Chassis Airflow 232124 Figure 1-4 There are five fans in the fan tray. If an in dividual fan fails , the o ther fans co ntinue to run. Senso rs monitor the internal air temperatures. The number of fan s in operation and their sp eed varies according to the intern al temperature for the quietest o peration possible. If the air temperature exceeds a desired thresho ld, the environmental mon itor disp lays warning mes sages.
Chapter 1 Product Overview Catalyst 4900M Half-Card Modules For safety reas ons, the AC power supp ly must be switched off and unplug ged befo re it is removed from a chassis or inserted in to a chassis. DC supp lies should have power shut off from the sou rce before they are removed. If only o ne power supply is used, y ou must use the supplied blank faceplate to cover the empty power b ay. Th e blank power su pply co ver maintains EMI s hield in g and p roper air flow thro ugh the chassis.
Chapter 1 Product Overview Catalyst 4900M Half-Card Modules WS-X4920-GB-RJ45 Half-Card Ethernet Module The WS-X49 20-GB-RJ4 5 half-card Ethern et mod ule p rovid es 2 0 10/10 0/1000-Mbps full-or half-d uplex ports. Figure 1-5 shows the module with the major features identified. Figure 1-5 WS-X4920-GB-RJ45 Half-Card Ethernet Module 1 232118 2 1 2 Module statu s LED Port LEDs Table 1 -4 lists the sp ecificatio ns for the WS-X4 920-GB-RJ4 5 half-card Eth ernet Mo dule.
Chapter 1 Product Overview Catalyst 4900M Half-Card Modules WS-X4904-10GE Half-Card Ethernet Module The WS-X4904-10GE half-card Ethernet mo dule provides 4 10-Gigabit Ethern et ports. Figure 1-6 sh ows the mod ule. WS-X4904-10GE Half-Card Ethernet Module 232119 Figure 1-6 1 2 1 2 Mo dule Status LED Po rt LEDs Tab le 1-5 list th e specifications for the WS-X490 4-10 GE half-card Ethernet module.
Chapter 1 Product Overview Catalyst 4900M Half-Card Modules WS-X4908-10GE Half-Card Ethernet Module The WS-X4908 -10GE module (Figure 1-7) is an 8-p ort 10-Gigabit Ethernet module that has the ability to operate as a 16 port 1-Gigab it mo dule by installing a Cisco TwinGig converter modu le in the X2 transceiver socket and then installing two 1-Gigabit SFP transceivers in the Twin Gig converter.
Chapter 1 Product Overview Catalyst 4900M Half-Card Modules Table 1-6 WS-X4908-10GE Half-Card Ethernet Module Specifications (continued) Specification Descriptio n Cable ty pe MM F or SMF (optical) or Category 5 or Category 6 (copper) Cabling distance Dep end ent on the type o f X2, SFP, o r SFP+ tran sceiver installed Plugg able transceivers su pport • X2 transceivers • SFP+ trans ceiver (using a Cisco OneX converter mo dule) • SFP transceiver (us ing a Cisco TwinGig converter mo dule) Mo
Chapter 1 Product Overview Catalyst 4900M Half-Card Modules WS-X4908-10G-RJ45 Half-Card Ethernet Module The WS-X490 8-10 G-RJ 45 half-card Eth ernet mo dule provides 8 10Gbps full-or h alf-du plex po rts. Figure 1-8 sh ows the mod ule with major features id entified .
Chapter 1 Product Overview Serial Number Location Table 1-7 WS-X4908-10G-RJ45 Half-Card Module Specifications (continued) Specification Descriptio n Plugg able transceivers su pport Not suppo rted Mo dule u pgrades available None Power over Ethernet Not suppo rted Serial Number Location Figure 1 -9 shows the location of the serial number fo r y our switch. You will need th is information when contacting Cisco for sup port.
CH AP T E R 2 Site Planning This chap ter describes how to p repare y our site for installation of th e Catalyst 490 0M switch and co ntain s th ese sections: • Note Site Environmental Requirements, p age 2-1 • Site Power Requ iremen ts, page 2 -2 • Groundin g Requirements , page 2-7 • Safety Overview, pag e 2-7 • Site Plann ing Checklist, pag e 2-9 A site plannin g checklist is p rovided on page 2 -8 to help ens ure that yo u complete all site planning activities before you install the switch.
Chap ter 2 Site Plan ning Site Power Requirements Coo ling air is drawn in thro ugh the right side and exhausted throu gh the left side of the chassis. Keep th e sides and rear clear of o bstru ction s, including du st and fo reign co nductive material, and away from th e ex hau st p orts of o ther eq uipment. Appendix A, “Specifications ,” lis ts the op eratin g and nonop eratin g enviro nmen tal site requirements for th e switches.
Chapter 2 Site Planning Site Powe r Requiremen ts Warning Ultimate disposal of this product should be handled according to al l national laws and regulations. Statement 1040 EMI Recommendations Fo llow th ese g uidelin es when settin g up the s ite wirin g. When plannin g the lo cation of the new system, co nsider electro magn etic in terface (EMI), the distance limitation s for sig nalin g, and connecto r co mpatib ility.
Chap ter 2 Site Plan ning Site Power Requirements Table 2-1 100 0 W AC-Input Power Supply Power Cords (continued) Locale Power Co rd Part Number AC Source Plug Co rdset Rating Typ e Power Cord Reference Illustration North America CAB-N5 K6A-NA= NEM A 6-1 5P 10 A, 250 VAC Figure 2-6 Sou th Africa, India CAB-BS546-C15-SA= BS 546 (SABS 164-1) 10 A, 250 VAC Figure 2-7 Switzerland CAB-9K10A-SW= United Kingdo m CAB-BS1363-C15-UK= SEV 1011 10 A, 250 VAC Figure 2-8 BS 136 32 13 A, 250 VAC
Chapter 2 Site Planning Site Powe r Requiremen ts CAB-CEE77-C15-EU=, CAB-7KACE= (Continental Europe) Plug: M2511 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: VSCC15 Figure 2-4 186576 Figure 2-3 CAB-C2316-C15-IT=, CAB-7KACI= (Italy) Plug: CEI 23-16/7 Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) 113349 Connector: IEC 60320 C15 Figure 2-5 CAB-US515-C15-US=, CAB-7KAC= (North America) Connector: IEC60320/C15 192260 Cordset rating 13A, 125V (8.2 feet) (2.
Chap ter 2 Site Plan ning Site Power Requirements Figure 2-6 CAB-N5K6A-NA (North America) Plug: NEMA 6-15P Cordset rating: 10 A, 250 V Length: 8.2 ft Figure 2-7 186570 Connector: IEC60320/C13 CAB-BS546-C15-SA (South Africa, India) Cordset rating 10A, 250V 6 ft. 0 in (1.83 m) Plug: BS 546 (SABS 164-1) Connector: IEC 60320 C15 196271 Figure 2-8 CAB-9K10A-SW=, CAB-7KACSW= (Switzerland) Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.
Chapter 2 Site Planning Grounding Requiremen ts Figure 2-9 CAB-BS1363-C15-UK=, CAB-7KACU= (United Kingdom) 13A fuse Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC 60320 C15 113351 Plug: BS 1363 Grounding Requirements Groundin g is recommended on all AC-input or DC-inpu t in stallations, using only approved cop per co nnectors.
Chap ter 2 Site Plan ning Safety Overview Warning Only trained and qualif ied personnel should be allowed to i nstall, replace, or service this equipment. Statement 1030 Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment i n the absence of a suitably installed ground conductor. Contact the appropriate elect rical inspection authority or an electrician if you are uncertain that suitable grounding is available.
Chapter 2 Site Planning Site Plannin g Checklist Preventing Electrostatic Discharge Damage Electrostatic discharge (ESD) damag e occu rs when electro nic cards or compon en ts are impro perly handled and can result in complete o r intermittent failu res. Follow these g uidelines to prevent ESD damage: • Always use an ESD-preventive wrist or ank le strap, an d ensure th at it makes maximum con tact with the sk in.
Chap ter 2 Site Plan ning Site Planning Checklist Table 2-2 Site Planning Checklist (continued) Task No.
CH AP T E R 3 Installing the Switch Revis ed: January 4, 2012 This chapter describ es h ow to install the Catalyst 490 0M switch. For first-time installations, perform the pro cedures in the following section s in the ord er lis ted.
Chapte r 3 Installin g the Switch Rack-Mounting the Switch Rack-Mounting the Switch A rack-moun t kit (69-1821-03) is included in the accessory kit for mo unting the switch in a standard 1 9-inch (48.3 cm) four-po st eq uipment rack where the depth of the rack (the distance measured b etween th e front and the rear po sts) does not ex ceed 3 2.5 in ches (8 2.5 cm).
Chapter 3 Installing the Switch Rack-Mounting the Switch – The rack must have sufficient vertical clearance to ins ert the chassis. The chassis heig ht is 2 U (3.5 inches (8.9 cm)). • The equ ipmen t rack is stab le and in no dan ger of falling over. • The equ ipmen t rack is pro perly ventilated. – Ensu re th at the sh elf is constructed to sup port the weight an d dimen sions of the ch assis. Fo r physical sp ecificatio ns, see Appendix A, “Specification s.
Chapte r 3 Installin g the Switch Rack-Mounting the Switch • Keep your back straight and lift with y our legs, no t y our back. If you mus t bend down to lift the chassis, b end at the kn ees, n ot at the waist, to reduce the strain on your lower back muscles. • Always disco nnect all external cables before liftin g o r moving the ch assis.
Chapter 3 Installing the Switch Rack-Mounting the Switch Note Step 2 Figure 3-1 illustrates how to attach th e front of the switch to the rack. You will also need to attach the rear of the s witch to th e rack. Attach the left an d rig ht L b rackets us in g the 12 M4 Phillips pan-head screws (six o n each side) prov ided in the rack-mount kit. (See Figure 3-1 .) Note that the L b rackets conn ect the ch assis to the rack.
Chapte r 3 Installin g the Switch Rack-Mounting the Switch Step 4 Install th e chas sis in the rack as fo llows: a. Positio n th e chass is in the rack (see Figure 3-2): b. Align th e mounting holes in the fron t and rear L brackets with the mo unting holes in the equipment rack. – If the chassis front panel is in the front of the rack, insert the rear of the ch assis between th e mo unting posts .
Chapter 3 Installing the Switch Connecting Power to the Catalyst 4900M Switch Installing the Cable Guide 232127 Figure 3-3 Step 6 Do not connect the power cord at this time. Proceed to the “Connecting Power to the Catalys t 49 00M Switch” sectio n o n pag e 3-7.
Chapte r 3 Installin g the Switch Connecting Power to the Catalyst 4900M Switch Grounding Pad Location 232131 Figure 3-4 1 1 Warning Step 2 Grou nding pad The plug-socket combination must be accessible at all times because it serves as the main disconnecting device. Statement 1019 Plug the power cord s in to th e power s upplies. Refer to Figure 3-5 for the plug location.
Chapter 3 Installing the Switch Connecting DC-Input Power to the Catalyst 4900M Switch Step 6 Verify power sup ply operation by lookin g at the chassis front panel power supply LEDs: • The PS1 or PS2 LED is lit green when the power supp ly and fans are fun ction ing normally. • The PS1 or PS2 LED is lit red when the power supply is not functioning normally.
Chapte r 3 Installin g the Switch Connecting DC-Input Power to the Catalyst 4900M Switch Step 3 Remove the terminal b lock cover by simultaneously s queezing the top and bottom sid es o f the cover, and at the same time, use a fin gernail to carefu lly p ry up on the top an d bottom clip s o n th e terminal block cover to release the cover from the termin al block. Pull the cover off of the terminal b lock and set th e cover aside. (See Figure 3-6.
Chapter 3 Installing the Switch Connecting DC-Input Power to the Catalyst 4900M Switch Figure 3-7 DC Power Cable Lug Dimensions .25 in (6.35 mm) 0.62 in (15.75 mm) 0.22 in (5.588 mm) 0.34 in (8.64 mm) 0.50 in (12.7 mm) 0.27 in (6.858 mm) Beveled wire entry 0.81 in (20.574 mm) 1.16 in (29.464 mm) 90 degrees +/- 5 degrees 0.09 in (2.29 mm) 1.47 in (37.3 mm) Note 331382 1.25 in (31.
Chapte r 3 Installin g the Switch Connecting DC-Input Power to the Catalyst 4900M Switch Step 7 Attach the appropriate size lug to the so urce DC groun d wire. The lug mu st have: Step 8 Con nect the so urce DC cables to the teminal block in th is order (see Figure 3-8): • A s ingle ho le able to accommodate th e 4 mm g rou nd post. • The barrel can be either straight or b ent as necessary.
Chapter 3 Installing the Switch Connecting DC-Input Power to the Catalyst 4900M Switch Caution To prevent short circuit or sho ck hazard after wirin g th e DC-input power sup ply, you must reinstall the terminal b lock cover.
Chapte r 3 Installin g the Switch Optical Connections You should also check the chassis front panel LEDs: • The PS1 or PS2 LED is green. • The PS1 or PS2 LED is red wh en the power sup ply is n ot functionin g n ormally. • The PS1 or PS2 LED is off when the power supply is not connected to a p ower source. From the system cons ole, enter the show power command to d isplay the p ower sup ply an d system statu s.
Chapter 3 Installing the Switch Configura ble Modules Required Tools You will need these tools to install switch ing modules in the Catalyst 49 00M series switch es: • • Note Numb er 1 and numb er 2 Phillips screwdrivers for the cap tive installation screws 3/16-inch flat-blade screwdriver for the captive installatio n screws • Antistatic mat or antistatic fo am • Wrist strap or oth er g rou nding device Wh enever you handle switching modules, use a wris t strap o r other ground ing device to preve
Chapte r 3 Installin g the Switch Configurable Modules To remove a switching modu le from a Catalys t 49 00M series s witch, perform th e fo llowing steps: Step 1 Step 2 Disco nnect any network in terface cables attach ed to the ports on th e switching mod ule that you intend to remove. Loosen the cap tive installation screws. (See Figure 3-10.
Chapter 3 Installing the Switch Configura ble Modules Warning Blank f aceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they cont ain electromagnetic int erference (EMI ) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, facepl ates, front covers, and rear covers are in place.
Chapte r 3 Installin g the Switch Configurable Modules Figure 3-11 Installing the Switching Module in the Chassis 1 232516 1 1 Captive screw Step 7 Carefully slide the switching modu le into the s lot u ntil b oth ejector levers engage the chassis s ides equally and the modu le is seated in th e back plane. Step 8 Use a screwdriver to tighten the cap tive installation screws on each end of the switching modu le faceplate.
Chapter 3 Installing the Switch Removing a nd Replacing the Power Supp ly Removing and Replacing the Power Supply This section d escribes how to remove and install the AC and DC-in put power sup plies. This information is presented in the following section s: • Warning Requ ired Too ls, page 3 -19 • Removin g a Power Supply, page 3-19 • Ins talling a Power Sup ply, page 3-20 Haz ardous volt age or energy is present on the backplane when the system is operating. Use caution when servicing.
Chapte r 3 Installin g the Switch Removing and Replacing the Power Supply Warning Step 6 Blank faceplates and cover panels serve three important functions: they prevent exposure t o hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassi s. Do not operate the system unless all cards, facepl ates, front covers, and rear covers are in place.
Chapter 3 Installing the Switch Removing and Replacing the Fan Assemb ly Step 11 Press the power s witch to th e on (| ) positio n. Step 12 Verify power sup ply operation by ch ecking the power sup ply’s front-panel LEDs. You shou ld see the following: Step 13 Check the power sup ply and system status from th e system console b y entering show power co mmand . Fo r more information on this comman d, refer to the command reference pu blication for yo ur switch.
Chapte r 3 Installin g the Switch Removing and Replacing the Fan Assembly Installing the Fan Assembly To install the new fan assembly, perform the fo llowing steps: Step 1 Hold the fan assembly with the captive screws on the left. Step 2 Place the fan assemb ly into the fan assembly bay so it rests on the ch assis, and then lift the fan assembly u p s lig htly, alig ning the to p and bo ttom g uides.
CH AP T E R 4 Troubleshooting the Installation This chap ter describes how to troublesho ot th e Catalyst 490 0M switch hardware installatio n and co ntain s th ese sections: • Getting Started , page 4 -1 • Problem So lving to the System Component Lev el, pag e 4-2 • Identifying Startup Pro blems , page 4-2 • Trou bles hooting the Power Su pply, page 4 -4 • Contacting Custo mer Serv ice, page 4-4 If your sy stem has pro blems starting u p, use the informatio n in this chapter to help iso late th
Chapter 4 Troubleshootin g the Installation Problem Solving to the System Component Level Problem Solving to the System Component Level The key to success when trou bles hooting the system is to isolate the pro blem to a sp ecific system compo nen t. The first step is to compare what the s ystem is doing to what it shou ld b e doing.
Chapter 4 Troubleshooting the Installation Identifying Startup Problems Table 4-1 Power Supply LED Meanings LED Meaning INPUT OK (AC) Th is LED sho uld turn green immediately wh en power is applied to the sup ply and th e power switch is set to ON. Green —AC in put voltag e is greater th an 80 .5 VAC ±4.5 VAC. Red—In a dual power supply config uration (alternate un it powered) the AC inpu t is less than 73 VAC ±3 VAC, or the power supply is turned o ff.
Chapter 4 Troubleshootin g the Installation Troubleshooting the Power Supply Troubleshooting the Power Supply To help is olate a power s ubsystem prob lem, perform the followin g steps : Step 1 Verify that the p ower supply is plu gged in and th at the on/off switch is set to ON (if the p ower supply is an AC s upply). Step 2 Look at the power sup ply LED (PS1 o r PS2 ). If the LED is off or if the LED is red, u nplug the power cord, and th en plug the power cord in.
Chapter 4 Troubleshooting the Installation Contacting Customer Service Serial Number Location 202519 Figure 4-1 SN: XXXNNNNXXXX Cisco Catalyst 4900M Switch Installation Guid e 78-18350-02 4-5
Chapter 4 Troubleshootin g the Installation Contacting Customer Service Cisco Catalyst 4900M Switch Installation Guide 4-6 78-18350-02
A P P E N D I X A Specifications Revis ed: January 4, 2012 This appendix provides cable and power s upply techn ical specifications fo r the Cataly st 4 900M switches. Console Port The con sole port is an RJ-45 receptacle. The Requ est to Send (RTS) sign al tracks th e state of the Clear to Send (CTS) input. Table A-1 lists the con sole po rt pinou ts.
Appendix A Specifications 10/100/1000BASE-T Management Port 10/100/1000BASE-T Management Port The 10 /100/10 00BASE-T managemen t po rt is an RJ-45 receptacle with a Link Status LED. Table A-2 lists the 10/100 BASE-T po rt pinou ts.
Appendix A Specifications Catalyst 4900M Switch Power Supply Specifications Figure A-2 100 0 W DC-Input Power Supply (PWR-C49M-1000DC) 2 2 3 1 232130 1 5 1 Captive installation screws 4 7 5 8 DC-in conn ector (positive (+) post) 2 Handles 6 DC-in connector (negative (–) post) 3 Power on/off switch 7 INPUT OK LED Ground po st 8 OUTPUT OK LED 4 Note 6 DC power cab le lugs are not supplied as part o f the accessory kit; th ey must be p urchased s eparately.
Appendix A Specifications Catalyst 4900M Switch Power Supply Specifications Figure A-3 DC Power Cable Lug Dimensions .25 in (6.35 mm) 0.62 in (15.75 mm) 0.22 in (5.588 mm) 0.34 in (8.64 mm) 0.50 in (12.7 mm) 0.27 in (6.858 mm) Beveled wire entry 0.81 in (20.574 mm) 1.16 in (29.464 mm) 0.09 in (2.29 mm) 90 degrees +/- 5 degrees 331382 1.25 in (31.75 mm) 1.47 in (37.3 mm) Tab le A-3 lists the AC-input an d the DC-input power supply specification s.
Appendix A Specifications Catalyst 4900M Switch Power Supply Specifications Table A-3 Catalyst 4900 Series Power Supply Specifications (continued) Item Specification Inrush value Cold turn on (PSU on for < 1 hour) 50 A for one cycle of AC Outp ut vo ltage 12 VDC Inp ut KVA rating 1.200 KVA DC-input p owe r supply Power supply ou tput Power supply dis sipatio n DC-input 960 W 320 W 27 A @ –48 VDC (Operating rang e –40 .5 to –56 VDC) 21.
Appendix A Specifications Catalyst 4900M Switch Power Supply Specifications Cisco Catalyst 4900M Switch Installation Guide A-6 78-18350-02
A P P E N D I X B Compliance Information and Translated Safety Warnings Note Only train ed and qualified service pers onnel (as d efin ed in IEC 60950-1 and AS/NZS 609 50) sho uld install, rep lace, or service th e equipment. Install the system in accordance with the U.S. Nation al Electric Code if you are in the United States.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 258—Fan Tray Removal Warning Warning When removing t he fan tray, keep your hands and fingers away from the spinning fan blades. Let the fan blades completely stop before you remove the fan tray. Waarschuwing Houd tijdens het verwijderen van de ventilator de handen en vingers uit de buurt van de draaiende ventilatorschoepen.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1003—DC Power Disconnection Warning Waar schuwing Varoitus Attention Before performing any of the following procedures, ensure that power is removed f rom the DC circuit. Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Varmi sta, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Av iso Advar sel Antes de executar qualquer um dos procedimentos a segui r, verifique se a energia foi removida do circuito DC. Før du udfører nogen af følgende procedurer, skal du sikre dig, at der ikke er strøm til jævnstrømskredsløbet. Statement 1004—Installation Instructions Warning Waarschuwing Varoitus Read the i nstallation instructions before connecting the system to the power source.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. Warnung Vor dem Anschließen des Systems an die Stromquelle die I nstallationsanweisungen lesen. Av vertenza Advarsel Aviso ¡Advertencia! Varning! Consultare le istruzioni di installazione pri ma di collegare il sistema all'al imentatore.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1006—Chassis Warning for Rack-Mounting and Servicing Warning To prevent bodily injury when mounting or servi cing this unit in a rack, you must take special precautions to ensure that the system remains stable.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Warnung Zur Vermeidung von Körperverlet zung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Varning! För att undvika kroppsskada när du instal lerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särski lda försiktighet såtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet: • Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Aviso Para evitar lesões corporais ao montar ou dar manutenção a esta unidade em um rack, é necessário tomar todas as precauções para garantir a estabil idade do sistema. As seguintes orientações são fornecidas para garantir a sua segurança: Advarsel For at forhindre legemesbeskadigelse ved montering eller servi ce af denne enhed i et rack, skal du sikre at systemet står stabilt.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Cisco Catalyst 4900M Switch Installation Guide B-10 78-18350-02
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1008—Class 1 Laser Product Warning Waar schuwing Varoitus Attention Class 1 laser product. Klasse-1 laser produkt. Luokan 1 lasertuote. Produit laser de classe 1. Warnung Laserprodukt der Klasse 1. Av vertenza Prodotto laser di Classe 1. Advarsel Aviso ¡Advertencia! Varning! Laserprodukt av kl asse 1. Produto laser de classe 1. Producto láser Clase I. Laserprodukt av kl ass 1.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Av iso Advar sel Produto a laser de classe 1. Klasse 1 laserprodukt.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1011—Staring into Laser Beam Warning Waar schuwing Varoitus Do not stare into the beam or view it directly with optical instruments. Niet i n de straal st aren of hem rechtstreeks bekij ken met optische instrumenten. Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla. Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1017—Restricted Area Warning Waarschuwing Varoitus This unit is i ntended for instal lation in restricted access areas. A restricted access area can be accessed only through the use of a special tool , lock and key, or other means of security. Deze eenheid is bestemd voor installatie in plaatsen met beperkte toegang.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Aviso Esta unidade deve ser instalada em áreas de acesso restrito. Uma área de acesso restrito só pode ser acessada com o uso de uma ferramenta especial, cadeado e chave ou outros mei os de segurança. Advarsel Denne enhed er beregnet til installation i områder med begrænset adgang.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1019—Main Disconnecting Device Warning Waarschuwing Varoitus The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device. De combinatie van de stekker en het elektri sch contactpunt moet te allen tijde toegankelijk zijn omdat deze het hoof dmechanisme vormt voor verbreking van de aansluiting. Pistoke/liitinkohta toimii pääkatkaisumekanismina.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1024—Ground Conductor Warning This equipment must be grounded. Never def eat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authorit y or an electrician if you are uncertain that suitable grounding is available. Waar schuwing Deze apparatuur dient geaard te zijn.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Varoitus Laitteiden on oltava maadoitettuj a. Älä koskaan ohita maajohdinta tai käytä lai tteita ilman oikein asennettua maaj ohdinta. Ota yhteys sähkötarkastusviranomaiseen tai sähköasentajaan, jos olet epävarma maadoi tuksen sopivuudesta. Attention Cet équipement doit être mis à la masse.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Cisco Catalyst 4900M Switch In stallatio n Guide 78-18350-02 B-19
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1028—More Than One Power Supply Warning Waarschuwing This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen ontkoppeld te worden om de eenheid t e ontkrachten. Varoitus Tässä laitteessa voi olla useampia kui n yksi virtakytkentä.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Aviso Esta unidade pode ter mais de uma conexão de fonte de alimentação. Todas as conexões devem ser removidas para interromper a alimentação da unidade. Advarsel Denne enhed har muligvis mere end en strømforsyningstilsl utning. Alle tilslutninger skal f jernes for at aflade strømmen fra enheden.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1029—Blank Faceplates and Cover Panels Warning Blank faceplat es and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that mi ght disrupt other equipment; and t hey direct the flow of cooling air through the chassis.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings ¡Advertencia! Las placas frontales y los paneles de rel leno cumplen tres funciones importantes: evitan la exposi ción a niveles peligrosos de volt aje y corriente dentro del chasis; reducen la interferencia electromagnética (EMI) que podría perturbar la operación de otros equi pos y dirigen el flujo de aire de enfriamiento a través del chasis.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Cisco Catalyst 4900M Switch Installation Guide B-24 78-18350-02
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1030—Equipment Installation Warning Waar schuwing Varoitus Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door bevoegd geschoold personeel. Tämän laitteen saa asentaa, vaihtaa tai huolt aa ainoastaan koulutettu ja laitteen tunteva henkilökunta.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Av iso Advar sel Somente uma equipe treinada e qualificada t em permissão para instalar, substi tuir ou dar manutenção a este equipamento. Kun uddannede personer må installere, udskifte komponenter i eller servicere dette udstyr.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1040—Product Disposal Warning Waar schuwing Varoitus Attention Warnung Av vertenza Advarsel Aviso ¡Advertencia! Varning! Aviso Advarsel Ultimate disposal of this product should be handled according to all national laws and regulations. Het uiteindelij ke wegruimen van dit product dient te geschieden in overeenst emming met all e nationale wetten en reglementen.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1045—Short-circuit Protection Warning Waarschuwing Varoitus Attention This product requires short-circuit (overcurrent) protection, to be provided as part of the bui lding installation. Install only in accordance with national and local wiring regulations. Voor dit product moet kortslui tbeveiliging (overstroombeveiliging) deel uitmaken van de installatie in het gebouw.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Warnung Av vertenza Advarsel Für dieses Produkt ist eine Kurzschlußsicherung (Überstromsicherung) erforderlich, die als Teil der Gebäudeinstallation zur Verfügung gestellt wird. Die Installation sollte nur in Übereinstimmung mit den nationalen und regionalen Vorschriften zur Verkabelung erfolgen.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1051—Laser Radiation Warning Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Waarschuwing Losgekoppelde of losgeraakte glasvezels of aansluitingen kunnen onzichtbare laserstraling produceren.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Attention Warnung Av vertenza Advarsel Aviso ¡Advertencia! Varning! Aviso Advarsel Les fibres ou connecteurs débranchés risquent d'émettre des rayonnements laser invisibles à l'œil. Ne regardez jamais directement les faisceaux laser à l'œil nu, ni d'ailleurs avec des instruments optiques. Unterbrochene Fasern oder Steckerverbindungenkönnen unsichtbare Laserstrahlung abgeben.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1072—Shock Hazard from Interconnections Warning Waarschuwing Voltages that present a shock hazard may exist on Power over Et hernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Varoitus Sisäisissä Ethernet (PoE) -virtapiireissä voi olla sähköiskun vaaran ai heuttavia jännitteitä, jos kytkentöihin käytetään eristämättömi ä paljaita metalliliit timiä tai -johtimia. Vältä tällaisia kytkentöjä, ell eivät paljaat metalliosat ole rajatussa pai kassa. Ilmoita valt uutetuille käyttäjille ja huol tohenkilöille vaarasta.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Varning! Det kan finnas spänningar på PoE-kretsarna (Power over Ethernet) som utgör risk för stötar om sammankopplingarna görs med ej isolerade, exponerade kontakter, ledare och/eller terminaler av metall. Undvik att använda sådana sammankopplingsmetoder, såvida inte de exponerade metalldelarna finns i en plats med begränsad åtkomst .
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1074—Comply with Local and National Electrical Codes Warning Waar schuwing Varoitus Attention Warnung Av vertenza Advarsel Aviso ¡Advertencia! Varning! Installati on of the equipment must comply with local and national electrical codes. Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschrif ten.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Statement 1075—Hazardous Voltage or Energy Present on DC Power Terminals Warning Waarschuwing Hazardous voltage or energy may be present on DC power terminals. Always repl ace cover when terminals are not in service. Be sure uni nsulated conductors are not accessible when cover is in place. Op DC-aansluitingspunten kunnen zich gevaarlijke voltages of energieën voordoen.
Appendix B Compliance Information and Translated Safety Warnings Translated Safety Warnings Aviso Os terminais de corrente contí nua podem fornecer tensão ou energia perigosa. Volte a colocar a tampa, sempre que os terminais não estiverem a ser utilizados. Certi fique-se de que os condutores sem isolamento não estão acessíveis, quando a tampa estiver colocada. ¡Advertencia! Puede haber energía o voltaje peli grosos en los terminales eléctricos de CC.
Appendix B Compliance Information and Translated Safety Warnings European Directives European Directives Statement 287—Declaration of Conformity to R&TTE Directive 1999/5/EC for the European Community, Switzerland, Norway, Iceland and Liechtenstein English: This equipment is i n compliance with the essent ial requirements and other relevant provisions of Directive 1999/5/EC.
Appendix B Compliance Information and Translated Safety Warnings Statement 6005—California Perchlorate Contamination Preve ntion Act (Title 22, California Cod e of Regulations, Malti [Maltese]: Magyar [Hungarian]: Norsk [Norwegian]: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-direktiv 1999/ 5/EF. Polski [Polish]: Português [Portuguese]: Este equipamento está em conformidade com os requisitos essenciais e outras provisões relevantes da Directiva 1999/5/EC.
Appendix B Compliance Information and Translated Safety Warnings Statement 6003—Taiwan Battery Statement 6003—Taiwan Battery Statement 6004—EU Battery Disposal and Recycling This pro duct may co ntain a battery. Recycle or disp ose of batteries in accord ance w\ith the battery manufacturer’s instru ction s and local/natio nal disp osal and recyclin g reg ulatio ns.
Appendix B Compliance Information and Translated Safety Warnings Statement 8000—Standards Compliance Table 1 Standards Compliance (continued) Sp ecifica tion Description EMC 47CFR Part 15 Class A (FCC Reg ulatio ns) AS/NZS CISPR22 Clas s A CISPR22 Class A EN5 5022 Class A ICES00 3 Class A VCCI Class A EN5 0082-1 EN6 1000-6-1 EN5 5024 EN3 00386 EN6 1000-3-2 EN6 1000-3-3 KN22 Class A KN24 CISPR24 Telecom (E1) AS/ACIF S016:200 1 CTR12 (9 7/520/EC) CTR13 (9 7/521/EC) TNA 11 7 IDA TS DCLN1 Jate Green Bo
Appendix B Statement 2007—EMC Environmental Conditions for Products Installed in the European Union Compliance Information and Translated Safety Warnings Statement 2007—EMC Environmental Conditions for Products Installed in the European Union This section applies to p rodu cts to be in stalled in the Europ ean Economic Union . The equipment is inten ded to op erate under the following environmental con ditions with resp ect to EMC: • A s eparate, defin ed locatio n that is under us er’s con trol.
Appendix B Compliance Information and Translated Safety Warnings EMC Class A Notices and Warnings Statement 340—Class A Warning for CISPR22 Warning Waar schuwing Varoitus This i s a class A product. In a domesti c environment this product may cause radio interference in which case the user may be required to take adequate measures. Dit is een product van klasse A. In een woonomgeving kan dit product radiostoring veroorzaken. In dat geval moet de gebruiker de juiste maatregelen nemen.
Appendix B Compliance Information and Translated Safety Warnings EMC Class A Notices and Warnings Statement 2017—Class A Notice for FCC Mo dify ing the equipment witho ut Cisco’s authorization may result in th e equipment no longer comply ing with FCC requ iremen ts for Class A digital d evices . In th at event, y our right to use th e equip ment may be limited by FCC regulations, and yo u may be required to correct any in terference to radio or television commun ications at yo ur own expense.
Appendix B Compliance Information and Translated Safety Warnings EMC Class A Notices and Warnings Statement 191—VCCI Class A Warning for Japan Warning This is a Class A product based on the standard of the VCCI Council. I f this equi pment is used in a domestic environment, radio interference may occur, in which case, the user may be required to take corrective actions.
Appendix B Compliance Information and Translated Safety Warnings GR-1089-CORE Issue 3 Documentation Statements Statement 294—Class A Warning for Korea Warning This is a Class A Device and is registered for EMC requirements for industrial use. The seller or buyer should be aware of this. If this type was sold or purchased by mistake, it should be replaced with a residenti al-use type.
Appendix B Compliance Information and Translated Safety Warnings Statement 8003—Telecom Approvals Listing Statement 7012—Equipment Interfacing with AC Power Ports This equipment shall be co nnected to AC mains provided with a surge p rotective device (SPD) at the service equipment co mplying with NFPA 7 0, the National Electrical Co de (NEC). Statement 7013—Equipment Bonding Networks This equipment is s uitab le fo r installation s u tilizing the Common Bondin g Network (CBN).
Appendix B Compliance Information and Translated Safety Warnings Statement 8003—Telecom Approvals Listing If this equipment causes harm to the telep hone network , the telephone co mpan y will n otify yo u in advance th at temporary d iscon tinuance of serv ice may be required. If ad vance notice is not p ractical, th e telephone co mpany will n otify yo u as soon as possible. You will be advised of y our right to file a complaint with the FCC if you believ e it is necess ary.
Appendix B Compliance Information and Translated Safety Warnings Statement 8003—Telecom Approvals Listing Statement 3015—CS-03 Certification for Canada The Catalyst 4900M switch meets the requirements of th e In dustry Canada label (CS-03 ) fo r telecommunicatio ns equ ipmen t. Table 4 lis ts the CS-03 approval numbers for th e equipment.
Appendix B Compliance Information and Translated Safety Warnings Japanese Electric Appliance and Radio Laws Japanese Electric Appliance and Radio Laws Statement 371—Power Cable and AC Adapter Statement 372—Wireless LAN Products Statement 384—Japanese Safety Reference Information Cisco Catalyst 4900M Switch Installation Guide B-50 78-18350-02
IN DEX A D accessory k it contents dimensions, chass is 3-1 airflow 1-3 documentation Catalys t 49 48E switches site env ironment audience 1 -3 2-2 within the chassis alarms, temperature altitude, op erating 1-6 i-vii conventions i- x organization i-v ii related 1-3 i-viii 1-3 E B electro static disch arge (ESD) blank facep late EMI reco mmend ation s 1- 8 brackets cab le 2-9 2-3 environmental requ iremen ts 2-1 environmental specification s 3-6 mou nting 1-3 3 -4 F C
Index G M GOOD LEDs management p ort pino ut ch ecking A-2 3-21 gro unding requirement, DC sys tems 2-7 O operating temperatu re, chassis H hardware descriptio n power s upply physical characteristics determining 2-3 Catalyst 4948 E heat dissipation, ch assis 1-3 management p ort fan as semblies 3-21 port status LED 1-3 operating 1-3 pinout hot swappin g humidity 1- 3 P 1-7 heat dissipation A-2 1- 5 power 1-3 co nnecting 3-7, 3- 9 DC gro unding req uirements 2-7 determi
Index chassis o perating R 1 -3 temperature, sto rage rack-mounting 3-2 temperature alarms red undancy 1-3 1-3 temperature thresho lds po wer supp ly 1-7 2-1 troubleshootin g rep lacing contactin g custo mer service fan assemblies 3-22 po wer supp lies 3-20 to 3-2 1 initial b oot 4 -4 4 -1 methodolo gy 4 -2 power supply 4-3, 4 -4 startup S 4-2 typo graphical conv entio ns i-x safety ensuring safety ov erview 2- 7 W 2- 7 trans lated safety warning s screws B-1 3-4 warn
Index Cisco Catalyst 4900M Switch Installation Gu ide IN-4 78-18350-02