User's Manual
3-18
Cisco Catalyst 4900M S witch Inst allati on Guide
78-18350- 0 2
Chapter 3 Installing the Swi tch
Configurable Modules
Figure 3-11 Installing the Switching Module in the Chassis
Step 7 Carefully slide the switching module into the slot until both ejector levers engage the chassis sides
equally and the module is seate d in the backplane.
Step 8 Use a screwdriver to tighten the captive installation screws on each end of the switching module
faceplate.
To check the status of the module, perfo rm the following steps:
Step 1 Ensure that the STATUS LED is green (module operationa l).
Step 2 When the switch is online, enter the show module command. Verify that the system acknowledges the
new module and that the module’s status is listed as good in the comman d output.
Step 3 If the module is not operational, reseat it . If the module is still not operational, contact your customer
service representative.