Chapter 4 Troubleshooting the Installation
Troubleshooting the Power Supply
Troubleshooting th e Power Supply
To help isolate a power subsystem probl em, perform the followin g steps:
Step 1 Verify that the power supply is plugged in and that the on/off switch is set to ON (if the power supply is
an AC supply).
Step 2 Look at the power supply LED (PS1 or PS2). If the LED is off or if the LED is red, unplug the powe r
cord, and then pl ug the powe r cord in. Be sur e the on/ off switc h is OFF before r emoving the power cor d
from the power supply.
Step 3 If the LED remains off, there might be a problem with the AC or DC source or the power cable.
Step 4 Connect the power cord to another power source if one is available.
Step 5 If the LED then lights, the problem is the first power source.
Step 6 If the LED fails to light after you connect the power supply to a new power source, replace the power
cord.
Step 7 If the LED still fails to light when the switch is connected to a different power source with a new power
cord, the power supply is probab ly faulty.
If you are unable to resolve the problem, contact a customer service representative for instructions.
Contacting Cust omer Service
If you are unable to solve a startup problem after using the troubleshooting suggestions in this chapter,
contact a customer service representative for assistance and further instructions. Before you call, have
the following information r eady to help your service pro vider assist you as quickly a s possible:
Date you received the switch
Chassis serial number (located on a label on the right of the rear of the chassis, see Figure 4-1)
Type of software and release number
Maintenance agreement or warranty information
Brief description of the probl em
Brief explanation of the steps you have already taken to isolate and resolve the proble m