Datasheet
Copyright © 1998 Cisco Systems, Inc. All rights reserved. Printed in USA. Cisco, Cisco Systems, the Cisco Systems logo, are registered trademarks and the Cicsco IOS logo are trademarks of Cisco Systems, Inc. in
the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. (9808R) 11/98 B&W
Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the
Cisco Connection Online Web site at http://www.cisco.com/offices.
Argentina • Australia • Austria • Belgium • Brazil • Canada • Chile • China • Colombia • Costa Rica • Croatia • Czech Republic • Denmark • Dubai, UAE
Finland • France • Germany • Greece • Hong Kong • Hungary • India • Indonesia • Ireland • Israel • Italy • Japan • Korea • Luxembourg • Malaysia
Mexico • The Netherlands • New Zealand • Norway • Peru • Philippines • Poland • Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Singapore
Slovakia • Slovenia • South Africa • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • Ukraine • United Kingdom • United States • Venezuela
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
European Headquarters
Cisco Systems Europe s.a.r.l.
Parc Evolic, Batiment L1/L2
16 Avenue du Quebec
Villebon, BP 706
91961 Courtaboeuf Cedex
France
http://www-europe.cisco.com
Tel: 33 1 69 18 61 00
Fax: 33 1 69 28 83 26
Americas
Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-7660
Fax: 408 527-0883
Asia Headquarters
Nihon Cisco Systems K.K.
Fuji Building, 9th Floor
3-2-3 Marunouchi
Chiyoda-ku, Tokyo 100
Japan
http://www.cisco.com
Tel: 81 3 5219 6250
Fax: 81 3 5219 6001
Supervisor Engine Module
• System status: Green (operational)/Red (faulty)
• Switch utilization load: 1- to 100-percent aggregate
switching usage
• Console (DB-25 female)
• Reset (switch recessed protected)
• 10BaseT management (RJ-45 female) data terminal
equipment (DTE): Green (good)/ orange (disabled)/off
(not connected)
48-Port 10/100 Ethernet Module
• 48 10/100 Ethernet ports, RJ-45 connectors
– Status: green (operational)/red (faulty)
– Link: green (operational)/red (faulty)
32-Port 10/100 Ethernet Plus 2-Port Gigabit Ethernet Module
• Status: green (operational)/red (faulty)
• Link: green (operational)/red (faulty)
6-Port Gigabit Ethernet Module
• 6 gigabit Ethernet ports with GBIC interfaces
– Status: green (operational)/red (faulty)
– Link: green (operational)/red (faulty)
18-Port Gigabit Ethernet Module
• 18 gigabit Ethernet ports with GBIC interfaces
– Status: green (operational)/red (faulty)
– Link: green (operational)/red (faulty)
Power Supply Indicators and Interfaces
• Fan cooling: integrated in hot-insertion/hot-extraction unit
• GOOD: green (good)
• FAIL: red (faulty)
• SNMP MIB supported
Chassis Physical Specifications
• Dimensions (H x W x D): 10.5 x 17.25 x 12 in.
• 6 rack units (RU) high
• Minimum weight: 27.5 lb. (12 kg)
• Maximum weight: 40 lb. (18 kg)
• Mounting: 19-in. rack-compatible (rack and cable guide
hardware included)
Power Requirements
• Input current:
– 6.0A 0A max. @ 100VAC 60Hz
– 3.0A 0A max. @ 200VAC 50Hz
• KVA rating: 0.58 KVA
• Output power: 400 watts per power supply
• Heat dissipation: 530 watts (1800 BTUs per hour)
Environmental Conditions
• Operating temperature: 32 to 104ºF (0 to 40ºC)
• Storage temperature: -40 to 167ºF (-40 to 75ºC)
• Relative humidity: 10 to 90%, noncondensing
• Operating altitude: -60 to 4000m
Safety Certifications
• UL 1950
• EN 60950
• CSA-C22.2 no 950
• IEC 950
Electromagnetic Emissions Certifications