Specifications

5-14
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 5 SNMP MIB Installation and Configuration
Tables and Groups
5.4.2 PumpCfgEntry Table
The cerent15216EdfaPumpCfgEntry table is used to set or get laser pump control mode configuration.
The associated table command displays a settings summary or allows you to set pumps. See Table 5-7
for variable definitions. The factory default pump control mode for the ONS 15216 EDFA2 is Constant
Gain Temperature Compensated. Cisco recommends that users contact the Cisco TAC prior to changing
this mode of operation.
5.4.2.1 Changing the Pump Control Mode
For Constant Gain Temperature Compensated mode, the system automatically sets the second pump to
this mode when either pump is set.
Constant Output Power mode is only valid for pump 2. If pump 2 is set to Constant Output Power Mode,
pump 1 is automatically set to Constant Pump Power mode with a value of 75 mW.
For Constant Pump Current or Constant Pump Power mode, the user should set both pump modes to be
the same.
Warning
The pump control modes Constant Pump Current, Constant Pump Power, and Constant Output Power
are to be used with very high precautions. They are service affecting and can reduce the life cycle of
the lasers if used in extreme conditions. The factory default setting and recommended mode of
operation is Constant Gain Temperature Compensated mode. Cisco recommends that users contact
the Cisco TAC before changing from this mode of operation.
Table 5-7 cerent15216EdfaPumpCfgEntry Variable Descriptions
Variable Syntax
Maximum
Access Description
cerent15216EdfaPumpCfgP
umpNum
cerent15216Edfa
PumpNumber
Not
Accessible
Laser pump number (1 or 2).
cerent15216EdfaPumpCfgC
ontrolMode
cerent15216Edfa
ControlMode
Read-write Laser pump control mode. When the
mode is set directly to constCurrent,
constPower, or constOutputPower, the
current value of ConstPumpCurrent,
ConstPumpPower, or ConstOutPower
is used as the constant parameter for
the new mode.
cerent15216EdfaPumpCfgC
onstPumpCurrent
Integer (0 to 300) Read-write Constant pump current (mA).
The current that is used when the
pump control mode is changed to
constCurrent.
cerent15216EdfaPumpCfgC
onstPumpPower
Integer (0 to 100) Read-write Constant pump power (mW). The
power that is used when the control
mode is changed to constPumpPower.
cerent15216EdfaPumpCfgC
onstOutPower
Integer (0 to 650) Read-write Constant output power (*10 mW). The
power that is used when the control
mode is changed to
constOutputPower.