Data Sheet Cisco ONS 15454 Multiservice Transport Platform Product Overview ® The Cisco ONS 15454 Multiservice Transport Platform sets the industry benchmark for dense wavelength-division multiplexing (DWDM) solutions delivering simple, fast, and intelligent DWDM capabilities and lowering capital and operating expenditures When Cisco introduced the Cisco ONS 15454 Multiservice Provisioning Platform (MSPP) for the metropolitan (metro) market in 1999, a clear demarcation was created between what is consider
Data Sheet Key Features and Benefits The Cisco ONS 15454 MSTP provides capital and operational efficiency by addressing the increasing demand for multiple services, greater transport capacity, networking flexibility, multiple distance options, and management simplicity in a single platform.
Data Sheet ● Ready-to-use card architecture for complete flexibility in configuring DWDM network elements: terminal nodes, optical add/drop nodes, degree-2 and multi-degree Reconfigurable Optical Add/Drop (ROADM) nodes, line amplifiers, and dispersion compensation within amplified or unamplified networks ● High shelf density for high-bandwidth (10-Gbps and 40-Gbps) wavelength services ● Fully reconfigurable optical add/drop multiplexers (ROADMs) for superior network flexibility and reduced complexity
Data Sheet ● Support by an advanced, cross-platform optical network management system (NMS), the Cisco Transport Manager (CTM), for unified network operations and interface to an operations support system (OSS). In addition to the integrated software features, the Cisco ONS 15454 MSTP is supported by an easy-to-use but powerful network design tool, the Cisco TransportPlanner.
Data Sheet Service Transparency Critical to offering a wide service mix is a DWDM system’s ability to offer the level of transparency required by the service. The Cisco ONS 15454 MSTP solution offers the choice of multiservice aggregation, wavelength aggregation, and wavelength transport, combined with integrated, intelligent DWDM transmission, in a single platform to optimize network costs for any mix of service types.
Data Sheet by the GE and the 10GE XPonder units (operating in Layer1 and Layer2 mode); by the OTU2 XPonder unit. ● Multiplex Section Protection In this case it is possible to leverage on the PSM unit to provide protection for the aggregated signal. Shared protection can be supported by the GE and the 10GE XPonder units leveraging on the revolutionary GR3 Ethernet protection (Cisco patented G.709 Rapid Resilient Ring Ethernet Protection mechanism), when operating in Layer2 mode. By integrating G.
Data Sheet The Cisco ONS 15454 MSTP offers ROADM capability that allows zero to 40 channels of passthrough or add/drop, A-Z wavelength provisioning, and full real-time power monitoring of each individual wavelength. Keeping traffic purely in the optical domain as much as possible has the added advantage of "future-proofing" a transport network.
Data Sheet ● Network topology auto-discovery ● Point-and-click node and network setup and regulation ● Automatic network-level optical power management and monitoring ● Single management interface (single IP address) for all the shelves in a node ● Network-level alarm correlation for a quick and easy troubleshooting (G.
Data Sheet ● Environmental alarm contacts ◦ 4-alarm output contact closures (standard): critical, major, minor, remote ◦ Up to 48 provisionable alarm contacts in systems equipped with Alarm Interface Controller (AIC-I) Network Security Features ● Four-level user control with provisionable timeout durations: super-user, provisioning, maintenance, retrieve ● Multiple user names and logged-in users ● RADIUS based authentication Maintenance Features ● Remote software downloads and in-service, hitle
Data Sheet Technical Specifications Table 1 provides the list of supported modules for Cisco ONS 15454 MSTP. Table 1.
Data Sheet Module Unit Name Optical band add/drop multiplexer 1-band, 50-GHz capable, C band AD-1B-xx.x 4-band, 50-GHz capable, C band AD-4B-xx.x Optical channel add/drop multiplexer 1-channel, 100-GHz, C band AD-1C-xx.x 2-channel, 100-GHz, C band AD-2C-xx.x 4-channel, 100-GHz, C band AD-4C-xx.
Data Sheet Module Unit Name Ethernet SFP – FE 10Base-T – Electrical ONS-SE-ZE-EL SFP – FE 100Base-T – Electrical ONS-SE-ZE-EL SFP – FE 100Base-LX – SM SFP3-1-IR/SFP-L.1.
Data Sheet Table 2 provides details about supported Interfaces and Protection types for the different Wavelength interface modules supported by Cisco ONS 15454 MSTP. Table 2. Wavelength Interfaces details Modules Supported Service Interfaces Protection Supported 2.
Data Sheet Modules Supported Service Interfaces Protection Supported MSPP-On-A-Blade OC-3/STM-1 No protection 1 module, DWDM XFP-based trunk OC-12/STM-4 1+1 APS on Client OC-48/STM-16 UPSR on Trunk GE OTU2 XPonder 10 GE LAN No protection 1 module, DWDM XFP-based trunk 10 GE WAN Optical-path protection OC-192/STM-64 Optical-path and equipment protection 10 Gigabit Fibre Channel OTU2 Table 3 and Table 4 provide details about wavelengths supported for the different Wavelengths Plan, in C b
Data Sheet Wavelength 1542.1 32-Channels x 1542.5 1542.9 x x x x x 1544.1 1544.5 x x 1543.3 1543.7 40-Channels x x x x 1544.9 x x x 1545.3 x x x x x x x x x 1548.9 x x x 1549.3 x x x x x x x x 1552.9 x x x 1553.3 x x x x x x x 1556.1 1556.5 x x x x 1556.9 x x x 1557.3 x x x x x x x © 2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
Data Sheet Wavelength 32-Channels 1560.2 40-Channels x 1560.6 x x x 1561.0 x x 1561.4 80-Chs x x x x x x x x 1561.8 Table 4. 64-Chs x x L band Wavelength Plan – 32-Channel Odd λ (nm) λ (nm) λ (nm) λ (nm) λ (nm) λ (nm) λ (nm) λ (nm) 1577.8 1581.1 1584.5 1587.8 1591.2 1594.6 1598.0 1601.4 1578.6 1582.0 1585.3 1588.7 1592.1 1595.4 1598.8 1602.3 1579.5 1582.8 1586.2 1589.5 1592.9 1596.3 1599.7 1603.1 1580.3 1583.6 1587.0 1590.4 1593.7 1597.
Data Sheet Item Specification Environmental Conditions Storage Temperature –40ºC to 70ºC (–40ºF to 158ºF) Operating Temperature 0ºC to 55ºC (32ºF to 131ºF) Normal Short Term 2 –5ºC to 55ºC (23ºF to 131ºF) Relative Humidity 5% to 85%, non condensing Normal Short Term 2 5% to 90% but not to exceed 0.024 kg water/kg of dry air 1. 19” mounting brackets have to be ordered separately 2. Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year.
Data Sheet ANSI (15454) System ETSI (15454E) System Optical Safety ● EN or IEC-60825-2 Third edition (2004-06) ● EN or IEC 60825-1 Consol. Ed. 1.2 – incl. am1+am2 (2001-08) ● 21CFR1040 (2004/04) (Accession Letter and CDRH Report) ● IEC-60825-2 Third edition (2004-06) ● ITU-T G.664 (2006) Miscellaneous ● Acoustic Noise ◦ GR-63-CORE, Issue 3 (2006) ◦ ETS 300 753 ed.1 (1997-10) ● Rain, Sand, Dust and Moisture Proofing ◦ AS 1939-1990, 4.2, IP 53 ● Mechanical Shock & Bumps ◦ AS1099- 2.
Data Sheet Standard Title Ethernet IEEE 802.1D IEEE Standard for local and metropolitan area networks — Media access control (MAC) Bridges IEEE 802.1Q IEEE Standard for Local and Metropolitan Area Networks — Virtual Bridged Local Area Networks IEEE 802.1ad Amendment to IEEE 802.1Q-2005. IEEE Standard for Local and metropolitan area networks — Virtual Bridged Local Area Networks IEEE 802.3ab 1000BASE-T Gbit/s Ethernet over twisted pair at 1 Gbit/s (125 MB/s) IEEE 802.
Data Sheet Product ID Description 15454-CC-FTA= Controlled cooling fan-tray assembly, includes fan-tray filter 15454E-CC-FTA= 15454-FTA3-T= Fan-tray assembly, includes fan-tray filter 15454E-FTA-48V= 15454E-CTP-MIC48V= Mechanical interface card, craft, timing, and power inputs, ETSI 15454E-AP-MIC48V= Mechanical interface card, alarm, and power inputs, ETSI 15454-AIR-RAMP= Air ramp (ships with ANSI 19” and 23” and ETSI 600mm mounting brackets) 15454E-AIR-RAMP= 15454-AIC-I= Alarm Interface Contr
Data Sheet Product ID Description 15454-10E-L1-L= 10-Gbps E-FEC multirate transponder card, 1x XFP-based client interface, full L-band tunable on 50-GHz ITU wavelengths, DWDM line with LC connectors 15454-10E-L1-xx.
Data Sheet Product ID Description 15454-40-WSS-CE= 40-channel wavelength selective switch 100-GHz, C-band, Even grid, MPO connectors for add path, LC connectors for interconnection, includes two 2-meter LC/LC fiber-optic cables 15454-40-WXC-C= 40-channel wavelength cross connect 100-GHz, C-band, Odd grid, MPO connector for interconnection with Mesh Patch Panel, LC connectors for interconnection, includes one 2meter LC/LC fiber-optic cable 15454-4MD-xx.
Data Sheet Product ID Description ONS-SI-155-SR-MM= OC-3/STM-1 SFP optics module, intermediate-reach, 1310-nm, multi-mode, industrial temperature, LC connector ONS-SI-155-I1= OC-3/STM-1 SFP optics module, intermediate-reach, 1310-nm, single-mode, industrial temperature, LC connector ONS-SI-155-L2= OC-3/STM-1 SFP optics module, long-reach, 1550-nm, single-mode, industrial temperature, LC connector ONS-SC-155-EL= SFP – STM-1 Electrical, standard coaxial (75ohm) connector 15454-SFP12-4-IR= OC-12/ST
Data Sheet Product ID Description 15216-LC-LC-10= Cable assembly, LC/PC-to-LC/PC, single-mode, 6.0m, 2-mm jacket 15216-LC-LC-20= Cable assembly, LC/PC-to-LC/PC, single-mode, 8.0m, 2-mm jacket 15216-LC-LC-MM-2= Cable assembly, LC/PC-to-LC/PC, multi-mode, 2.0m, 2-mm jacket 15216-LC-LC-MM-5= Cable assembly, LC/PC-to-LC/PC, multi-mode, 5.0m, 2-mm jacket 15216-LC-SC-5= Cable assembly, LC/PC-to-SC/UPC, single-mode, 4.0m, 2-mm jacket 15216-LC-SC-10= Cable assembly, LC/PC-to-SC/UPC, single-mode, 6.
Data Sheet For More Information For more information about the Cisco ONS 15454 Multiservice Transport Platform, contact your local account representative or visit Cisco at: www.cisco.com/go/optical or www.cisco.com/go/IPoDWDM. Printed in USA © 2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.