Datasheet
© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 15
Feature
Cisco ASA 5505;
Security Plus
Cisco ASA 5510;
Security Plus
Cisco ASA 5512-X;
Security Plus
Cisco ASA 5515-X
Expansion I/O
–
4 GE Copper or
4 GE SFP
6 GE Copper or
6 GE SFP
6 GE Copper or
6 GE SFP
Serial Ports
1 RJ-45 console
2 RJ-45, console and
auxiliary
1 RJ-45 console
1 RJ-45 console
Solid State Drive
–
–
1 slot, 120 GB MLC SED
1 slot, 120 GB MLC SED
Memory
512 MB
1 GB
4 GB
8 GB
Minimum System
Flash
128 MB
256 MB
4 GB
8 GB
System Bus
Multibus architecture
Multibus architecture
Multibus architecture
Multibus architecture
Operating
Temperature
32 to 104°F (0 to 40°C)
32 to 104°F (0 to 40°C)
23 to 104°F (–5 to 40°C)
23 to 104°F (–5 to 40°C)
Relative Humidity
5 to 95 percent
noncondensing
5 to 95 percent
noncondensing
10 to 90 percent
noncondensing
10 to 90 percent
noncondensing
Altitude
Designed and tested for 0
to 9840 ft (3000m); agency
approved for 2000m
Designed and tested for 0 to
9840 ft (3000m); agency
approved for 2000m
Designed and tested for 0 to
15,000 ft (4572m)
Designed and tested for 0
to 15,000 ft (4572m)
Shock
1.14 m/sec (45 in./sec) 1/2
sine input
1.14 m/sec (45 in./sec) 1/2
sine input
70G, 4.22 m/sec
70G, 4.22 m/sec
Vibration
0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
Acoustic Noise
60 dBa max
60 dBa max
64.2 dBa max
64.2 dBa max
Nonoperating
Temperature
–13 to 158ºF (–25 to 70ºC)
–13 to 158ºF (–25 to 70ºC)
–13 to 158ºF (–25 to 70ºC)
–13 to 158ºF (–25 to 70ºC)
Relative Humidity
5 to 95 percent
noncondensing
5 to 95 percent
noncondensing
10 to 90 percent
noncondensing
10 to 90 percent
noncondensing
Altitude
0 to 15,000 ft (4570m)
0 to 15,000 ft (4570m)
Designed and tested for 0 to
15,000 ft (4570m)
Designed and tested for
0 to 15,000 ft (4570m)
Shock
30G
30G
70G, 4.22 m/sec
70G, 4.22 m/sec
Vibration
0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
1.12 Grms2 (3 to 500 Hz)
random input
1.12 Grms2 (3 to 500 Hz)
random input
Power
Input (per Power Supply)
AC Range Line
Voltage
100 to 240 VAC
100 to 240 VAC
100 to 240 VAC
100 to 240 VAC
AC Normal Line
Voltage
100 to 240 VAC
100 to 240 VAC
100 to 240 VAC
100 to 240 VAC
AC Current
1.8A
3A
4.85A
4.85A
AC Frequency
50/60 Hz
47/63 Hz
50/60 Hz
50/60 Hz
Dual-Power Supplies
None
None
None
None
DC Domestic Line
Voltage
See the ASA 5500 Series
Hardware Installation
Guide
See the ASA 5500 Series
Hardware Installation Guide
–40.5 to 56 VDC (–48 VDC
nominal)
–40.5 to 56 VDC (–48 VDC
nominal)
DC International Line
Voltage
See the ASA 5500 Series
Hardware Installation
Guide
See the ASA 5500 Series
Hardware Installation Guide
–55 to –72 VDC
(–60 VDC nominal)
–55 to –72 VDC
(–60 VDC nominal)
DC Current
See the ASA 5500 Series
Hardware Installation
Guide
See the ASA 5500 Series
Hardware Installation Guide
15A (maximum input)
15A (maximum input)
Output
Steady State
20W
150W
51W
65W
Maximum Peak
96W
190W
56W
70W