Specifications

5-23
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide for SCCP (version 3.0)
OL-4652-01
Chapter 5 Parameters and Defaults
Operational Parameters
SigTimer
Description
This parameter controls various timeout values for the Cisco ATA. Table 5-3 contains bit definitions of
this parameter.
Value Type
Bitmap
Default
0x00000064
Voice Configuration Menu Access Code
318
Related Parameter
CallWaitTone, page 5-36
Ta b l e 5-3 SigTimer Parameter Bit Definitions
Bit Number Definition
0-7 Call waiting period—The period between each burst of call-waiting tone.
Range: 0 to 255 in 0.1 seconds
Default: 100 (0x64=100 seconds)
8-15 Not used for SCCP.
16-21 Reserved—Should be set to 0.
22-25 Reorder delay—The amount of time before the Cisco ATA plays a fast-busy tone to its FXS port after the
far-end party disconnects a call.
Range: Values of 1 to 14 designate the number of seconds of the reorder delay; a value of 15 means that the
Cisco
ATA will not play a fast-busy tone.
Default value: 0 (a four-second reorder delay)
26-27 Minimum hook flash time—The minimum on-hook time required for a hook flash event.
Range: 0 to 3
Default: 0 (60 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms.
28-31 Maximum hook flash time—The maximum on-hook time allowed for a hook flash event.
Range: 0 to 15
Default: 0 (1000 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms, 4=400 ms, 5=500 ms, 6=600 ms, 7=700 ms, 8=800
ms, 9=900 ms, 10=1000 ms, 11=1100 ms, 12=1200 ms, 13=1300 ms, 14=1400 ms, 15=1500 ms.