Clearance to the I/O side view is such that the LED can be read.
Airflow around the WPAN module and through the vents is unrestricted.
Temperature around the unit does not exceed 140 degrees F (60 degrees C). If the WPAN module is installed in a closed or
multi-rack assembly, the temperature around it might be higher than normal room temperature.
Relative humidity around the WPAN module does not exceed 95% (non-condensing).
Altitude at the installation site is not higher than 10,000 feet.
After replacing or installing a module in the router, you must update the label (on the router exterior) that lists the module types
contained in the router. The label must list the FCC ID number and the IC Certification number for each module installed in the
router.
Before installing the OFDM module, verify that the following guidelines have been met:
The module can be located in the same host as - and co-transmit with a cellular radio and a WiFi radio but not with any other
radios.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Installations of this product are limited to the CGR1000 router product series.
Usage of antenna and antenna cabling options other than those listed in Table 4 and Table 5 will void the users authority to
operate the equipment.
Changes or modifications not expressly approved CISCO will void the user's authority to operate the equipment.
Installations of this device must ensure a distance of at least 20 cm from persons of the general public to comply with RF-exposure
requirements.
Installation Warning Statements
This section includes the basic installation warning statements. Translations of these warning statements appear in the Regulatory
Compliance and Safety Information for Cisco Connected Grid Router 1000 Series Routers.
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
Danger
To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient
temperature of: 140°F (60°C) Statement 1047
Danger
To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 1.75 in. (4.4 cm) Statement 1076
Danger