Technical Specs

Table Of Contents
transport input all
transport output all
!
ntp server 192.168.100.250
netconf max-sessions 16
netconf ssh
!
end
SOL-ASR-7#
Checking and Upgrading the WPAN Firmware Version
This section describes how to check the WPAN hardware and firmware versions and perform firmware upgrades.
WPAN firmware is not upgraded automatically when the CGR is upgraded to a new image integrated with new WPAN
firmware.
Note
Minimum Firmware Version
The minimum supported firmware version for FSK WPAN is 5.2.82.
The minimum supported firmware version for OFDM WPAN is 5.7.27.
Checking the WPAN Hardware and Firmware Versions
To check the version of the WPAN hardware in slot 4, run the following command:
Router# show wpan 4/1 hardware hwversion
hardware version: Itron OWCM
Hardware rev : 3.1
Model name : OWCM
Hardware ID : RFLAN/3.60/3.80
To check the installed firmware version of the WPAN, run the following command:
Router# show wpan 4/1 hardware version
firmware version: 5.5.48, apps/bridge, master, 4b89e37, Apr 4 2014
If the firmware integrated in the CGR image is later than the one installed on the WPAN, the CGR displays the following message:
Router# show wpan 4/1 hardware version
!NOTE! Current version of WPAN firmware is old. Please upgrade WPAN firmware.
firmware version: 5.2.82, apps/bridge, cg-mesh-5.2.82, c181854, Apr 24 2013
The show wpan <slot >/1 config command also displays the WPAN firmware version:
cgr1000# show wpan 4/1 config
module type: RF-WPAN (IEEE 802.15.4e/g RF 900MHz)
ssid: migration_far2
panid: 7224
transmit power: -34
channel: 254
dwell: window 20000 max-dwell 400
beacon async: min-interval 262 max-interval 1048 suppression-coefficient 1
security mode: 1
81
REVIEW DRAFT - CISCO CONFIDENTIAL