Technical Specs
Table Of Contents
- Cisco Connected Grid WPAN Module for CGR 1000 Series Installation and Cisco Resilient Mesh Configuration Guide (Cisco IOS)
- Cisco Connected Grid WPAN Module for CGR 1000 Series Installation and Cisco Resilient Mesh Configuration Guide (Cisco IOS)
- Hardware Overview
- WPAN Antennas, Connectors, and Cables
- Installing and Removing the Module
- Technical Specifications
- Information About Cisco Resilient Mesh and WPAN
- Configuring Cisco Resilient Mesh and the WPAN Module
- Configuring the WPAN Interface
- Configuring the CGM WPAN OFDM Module
- Configuring Adaptive Modulation
- Configuring Group Multicast
- Configuring RPL
- Configuring IPv6
- Configuring PON RPL
- Configuring the Power Outage Server
- Configuring QoS
- Configuring Cisco Resilient Mesh Security
- Configuring IPv6 Multicast Agent
- Configuring Dual-PHY WPAN
- Configuring DTLS Relay for EST
- Configuring Wi-SUN Mode
- Verifying Connectivity to the CGR
- show Command Examples
- Debugging the WPAN Module
- Sample Router Configuration
- Sample CGR and ASR Configuration
- Checking and Upgrading the WPAN Firmware Version
- Related Documentation
- Obtaining Documentation and Submitting a Service Request
Router(config)# no hw poweroff 4
Step 4 Wait for WPAN power-up messages, and then wait at least 500 seconds before proceeding with any task on a WPAN
under reload. Then, check WPAN status and hardware version:
Example:
Router# show ip interface brief | inc Wpan
Wpan4/1 unassigned YES unset up up
Router# show wpan 4/1 hardware version
firmware version: 5.5.48, apps/bridge, master, 4b89e37, Apr 4 2014
Upgrading to a non-integrated WPAN firmware
You can upgrade to a custom WPAN firmware other than the one integrated in current CGR image. The appropriate WPAN firmware
image must be copied and available on the CGR flash in the root directory.
To upgrade the WPAN to a non-integrated, custom firmware, follow these steps:
Procedure
Step 1 Install the non-integrated firmware:
Example:
Router(config-if)# install-firmware <firmware-filename>
Firmware upgrade starting. This may take several minutes. Please do not interrupt.
.....
Step 2 Power down the WPAN module:
Example:
Router# config t
Router(config)# hw poweroff 4
Step 3 Wait for WPAN power-down messages, and then wait another 60-90 seconds. Then, power up the module:
Example:
Router(config)# no hw poweroff 4
Step 4 Wait for WPAN power-up messages, and then wait at least 500 seconds before proceeding with any task on a WPAN
under reload. Then, check WPAN status and hardware version:
Example:
Router# show ip interface brief | inc Wpan
Wpan4/1 unassigned YES unset up up
Router# show wpan 4/1 hardware version
firmware version: 5.5.48, apps/bridge, master, 4b89e37, Apr 4 2014
83