Leaflet

Testing with Bourns Primary Protection with Cisco xDSL interfaces
1. Surge and Power Cross tests
Summary:
Surge and Power Cross tests were done on Cisco xDSL interfaces: CISCO877, CISCO877W, CISCO877M,
HWIC-1VDSL, and EHWIC-VA-DSL-x
All tested units pass 6000 Volts Surge testing with all variations of Bourns 7040-01 NID (Network
Interface Devices) devices.
The CISCO877 router passes Power Cross without Bourns NID devices. However the CISCO877M fails
due to oscillatory behavior when a standard voltage GDT-only device is used as Primary Protection. The
CISCO877M passes Power Cross when used with a GDT with TBU device because the TBU limits
circulating current.
The HWIC-1VDSL and EHWIC-VA-DSL-x interfaces pass power cross with GDT devices, with or without
TBU support.
Cisco CISCO888E and CISCO888EW, and HWIC-4SHDSL-E , G.SHDSL interfaces were tested per standard
K.21 testing. This G.SHDSL interface passed Power Cross with an external GDT network with no issues
during normal compliance testing. This includes the HWIC and the fixed version of this port.
Passing was determined by link up with Broadcom multimode CO simulator without loss of rate. Failure
was loss of link or lowered data rate indicating damage.
Currently the Cisco877 family is announced as EOS with last sale date of Dec 2011. HWIC-1VDSL and
EHWIC-VA-DSL-x are new products.
Conclusions:
All of the tested Cisco DSL products pass 6000 Volts Surge tests with any Bourns GDT Primary Protection
NID Device. The Cisco CISCO877M fails Power Cross due to the voltage rating of the Primary Protection
GDT versus the voltage rating of the Sidactor in the Secondary/in-circuit protection. The Bourns GDT
with the TBU allows the CISCO877M to pass Power Cross testing with transient current blocking,
damping the circulating current in the transformer.
Therefore for full coverage of Surge and Power Cross we recommend the Bourns GDT with TBU, 7040-
01-, containing a 2377-45-BC-TBU Station Protector. If Power Cross in the field is not an issue, then any
of the Bourns GDT three-pin devices, 2377-45-BC, will work. Other low capacitance three pin GDT NID
devices should work as well.

Summary of content (9 pages)