Release Notes

Version 5.3.0.6 Sourcefire 3D System Release Notes 34
Known Issues
Files that are intentionally not stored by the system (such as files seen for
the first time, or files outside the size limit) incorrectly appear with a File
Storage value of
Failed. (141196/CSCze92629, 141505/CSCze92908)
The system-provided saved search Public Addresses Only incorrectly includes
the private 172.x.x.x IP address range. (141285/CSCze92654)
When you update your appliances to a new software version, the update
overwrites any changes you made to default dashboard pages. As a
workaround, perform a system backup before updating, then restore the
backup. (141363/CSCze92812)
Reports do not resolve DNS names for IP addresses, even if you have
configured them to do so. (141393/CSCze92797)
When you configure a device inline between a host and a web server, block
the web server by URL in your access control policy, enable the
Cisco-provided block response page, then attempt to access the web server
from the host, a session timeout may result if the open connection limit of
the server’s operating system is reached. (141440/CSCze92753)
In some cases, excessive saved revisions to the intrusion policy may cause
system performance issues. (141501/CSCze92792, 141754/CSCze92960)
On 3D9900 devices, passive interfaces not in security zones do not
generate intrusion or connection events. As a workaround, create and
specify a security zone for all passive interfaces on this device model.
(141663/CSCze93022)
When you edit a saved search, the previously configured name of the
search does not appear in the Name field; the field is empty.
(142060/CSCze93463)
When the system sends a file for sandbox analysis and the cloud does not
respond within 50 minutes, the file’s status still appears as Sent for Analysis
instead of indicating that analysis has timed out. (142309/CSCze93757)
When you are using two Defense Centers in a high availability configuration,
you cannot generate troubleshooting reports for a Defense Center from the
web interface of its high availability peer. You must generate
troubleshooting reports directly from the Defense Center you need the
reports for. (142645/CSCze93908)
If you create a new report (Overview > Reporting > Report Templates) and
attempt to Insert Report Parameter while viewing the web interface with
Internet Explorer 11, no report parameters are added to the report section
description. As a workaround, install and use Internet Explorer 10.
(142950/CSCze94011)
The Sourcefire 3D System User Guide does not reflect that if your Defense
Center loses connectivity to the Internet, the system may take up to 30
minutes to generate an Advanced Malware Protection health alert.
(143070/CSCze94138)