Release Notes
14 Release Notes for 200, 300, 500, and ESW2 Series Switches Firmware Version 1.3.0
Release Notes
Problem: Notification Recipients table entry becomes un-editable with an
incorrect or missing parameter. (CQ133316)
Solution: There will be an asterisk by any values for a table entry which are
incorrect. This can be caused by the deletion of users, views, etc. If any of these
values are incorrect, then the entry will be un-editable. First add the missing user,
view, etc, in order to edit the entry. The delete button still works regardless of
whether the values are correct or not.
Problem: The result of cable length test for 100 meters is incorrect. It will show
between 110 to 140 meters. (CQ132941)
Solution: There is no workaround.
Problem: The maximum number of IPv6 ACEs that can be applied on an interface
is 244, not 512 as documented. The user receives the message "Cannot apply
because of a lack of hardware resources." (CQ130161)
Solution: There is no workaround.
Problem: If changing the active image with the menu CLI, the active image after
reboot field is not updated. If you change the image number and reboot, then the
image does change, but the display in the menu CLI is incorrect. (CQ132211)
Solution: There is no workaround.
Problem: When using the CLI, any time that DNS is used, the user is blocked from
interacting with the CLI until the DNS lookup has completed. (CQ133234)
Solution: The user must wait until the DNS lookup has completed before issuing
another command.
Problem: When a DVA authorized port tries to re-authenticate and RADIUS
attributes no longer include VLAN attributes, reauthentication should fail and the
port should become unauthorized. This is not happening, and the port does not fail.
(CQ131469)
Solution: Do not remove VLAN attributes on a RADIUS server or unplug the
network cable and plug it back in to force the failure.
Problem: Egress rate shaping does not work as expected. Configuring egress
shape on Gigabit ports or on Combo ports between 64k to 5000k, will always
result in 2 Million Bits. This is resolved with the new hardware release 1.1.1.8. It still
exists on HW V01. It also does not work on SG300-52/52P & SG200-52/52P
switches. (CQ123397 and CQ130715)
Solution: There is no workaround.