Open Bugs in Software Version 2.1.0
This section lists that bugs that are acknowledged in software version 2.2.5.68:
CSCuz45730 Symptom: When negotiating 60W PoE with Cisco PD
switches, Cisco PoE-PSE switches sometimes are not able to
provide 60W and provide 30W only.
Workaround: Connect PD switch to PSE switch before PSE
switch boot up. Or disconnect then connect PD switch when
issue happens. Or use static 60 watt.
Table 4 Open Bugs in Software Version 2.1.0
Bug ID Description
CSCux77651 Symptom: When applying policer on ingress interface and
sending traffic with multiple priority may result in dropping of
higher priority traffic on lower speed egress ports.
Workaround: There is no workaround.
CSCux89413 Symptom: Auto SmartMacro—In some cases, the interface
is set to BPDU guard erri-disable state after replacing the
device connected to the interface from a phone/desktop to
switch.
Workaround: Either disable persistent setting on the
interface, or, after the issue occurs, remove the desktop/phone
macro from the interface, reactivate the port, and then connect
the switch to the interface.
CSCux89418 Symptom: When connecting Sx350P as PD to Sx300P/
Sx500P as PSE, Sx350P reboots when disconnecting AC
power. After rebooting, Sx350P powers up and functions as
expected.
Workaround: There is no workaround.
Table 3 Open Bugs in Software Version 2.2.0.63 (Continued)
Bug ID Description