Release Notes
Rel Notes for SF250, SG250, SF350, SG350, SG350X, SG350XG, SF550X, SG550X, and SG550XG Series Switches, 2.2.5.68 9
Release Notes
Open Bugs in Software Version 2.0.0
This section lists that bugs that are acknowledged in software version 2.0.0.
CSCux89582 Symptom: Interface is suspended (down) when connecting
a copper SFP (MGBT1/GLC-T SFP) with no cable. This issue
happens when inserting uplink GE ports (for example, gi3 or
gi4) of Sx350/Sx250 or to XG network ports.
Workaround: To prevent interface suspension, insert the
cable to SFP before inserting SFP to port. If port is already in
suspended state, insert the cable into SFP and then activate
the suspended port, and the port moves to up state.
CSCux89585 Symptom: If CDP and LLDP are both enabled on a port,
disabling one of them may cause the remaining protocol PoE
negotiation to fail.
Workaround: Do not enable both CDP and LLDP power
negotiation at the same time. If the issue occurs, disconnect
and then reconnect cable to PD.
CSCux89597 Symptom: In port limit mode, the default admin power limit
value for all types of ports (AF, AT, and 60W PoE) is 30 watts.
Workaround: Manually set a limit of 60 watts if needed.
CSCux89611 Symptom: Power negotiation for 60W PoE via LLDP may
take up to 1 minute to complete.
Symptom: There is no workaround.
CSCux89626 Symptom: When connecting 60W PD to switch, in some
cases power indication on switch is higher than 60W. This bug
is a display issue. Actual PD consumption is 60W
Workaround: There is no workaround.
Table 4 Open Bugs in Software Version 2.1.0 (Continued)
Bug ID Description