Release Note

Cisco Unified ICM/Contact Center Enterprise & Hosted Editions, Release 7.5,
Hardware and System Software Specification
©2008-2011 Cisco Systems, Inc. 56
Table 6-68: CAD Agent and Supervisor Desktop Servers
Server Class Type Hardware, software requirements and remarks
GEN-10-005-Class CAD Supervisor Desktop (CSD)
CAD Desktop Administrator (CDA)
Operating system and other software
Windows compatible full-duplex sound card (if using
Cisco IP Communicator and/or Silent Monitor)
See Section 7.1.6,
CTI Supported Platforms
GEN-10-005-Class CAD Agent Desktop Other hardware Requirements
100/1000 Ethernet port
Operating system and other software
Windows compatible full-duplex sound card (if using
Cisco IP Communicator)
See Section 7.1.6,
CTI Supported Platforms
6.7.18 Remote Monitoring Suite (RMS)
RMS is highly scalable and deployed in a number of configurations. Most typically, the LGMapper and LGArchiver
nodes are deployed as co-resident in a single server. The Listener is separately deployed; a fault tolerant duplexed
configuration is supported. Multiple Alarm Tracker client nodes can be served from a single LGMapper/LGArchiver
pair.
Separate physical disks are required in the Listener server, allowing for segregation of o/s and “phone home” customer
database. 2GB memory is required for the small system configuration, and a full 4GB for larger (<25 customer)
systems.
Special consideration must be given to migration of Windows 2000 to Windows Server 2003 RMS-monitored
customers, and of the Listener node itself. Consult the Cisco Remote Monitoring Suite Administration Guide, Release
2.1 for more details.
Note: RMS is not supported with Unified System CCE deployments.