Field Calibration Software (FCS-100) User Guide For SLITE series&TF series &DB tiles R59770395/00 08/05/09
Barco nv Media & Entertainment Division Noordlaan 5, B-8520 Kuurne Phone: +32 56.36.89.70 Fax: +32 56.36.883.86 E-mail: sales.events@barco.com Visit us at the web: www.barco.
Changes Barco provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied warranties or merchantability and fitness for a particular purpose. Barco may make improvements and/or changes to the product(s) and/or the program(s) described in this publication at any time without notice. This publication could contain technical inaccuracies or typographical errors.
1. concept and installation 1. CONCEPT AND INSTALLATION About the Field Calibration When swapping LED frame, it is possible that the color uniformity cannot be reached for the whole wall. To solve this problem, Barco developed a tool, Field Calibration software, namely FCS-100. When using this tool, calibrate the frame by modifying LMT data to obtain good uniformity of the LED screen.
1. concept and installation 1.1 Basic concept Different steps to be taken 1. Swap the new frame. Follow the service manual for more detail about changing a frame on site. 2. Configure and adjust the wall with Director Toolset 3. Calibrate the wall with Director Toolset, use the desired calibration level 4. Display a white image and view it. If there is still different in uniformity, install FCS-100 software on controller PC. 5.
1. concept and installation 1.2 Installation procedure How to install 1. Download the installation pack of FCS-100 2. Double click on setup.exe Image 1-1 3. Press next to run the installation Image 1-2 4.
1. concept and installation Image 1-4 Press next to start installation 5.
1.
1.
2. Field calibration 2.
2.
2. Field calibration 2.1 Quick start Physical Connect 1. For D-320/DMP-100 based digitizer, connect COM port of digitizer with controller PC Control PC (A) Display (B) COM1 (F) Digitizer (C) Fiberlink TX (D) Fiberlink RX (E) Optional (G) Image 2-1 setup 1 A B C D E F Computer Display devices D-320/DMP-100 based Digitizer FiberLink transmitter FiberLink receiver COM1 Or, For DX-700 based digitizer, connect it with controller PC via Ethernet.
2. Field calibration (1) (2) (3) (4) (5) Image 2-3 4. Field adjust - (1) Click on Field Adjust tab - (2) Press “Backup/Restore LMT Data” to back up LMT data of the desired tiles/frames in the pop up dialog. - (3) Input tile address in text, and click the frame number in “select frame” , the selected one in red colored, is positioned on LED wall with outline too. Check if the desired frame is selected. - (4) Press “Read” in “LMT Data” frame, x, y,and Y value is shown in the table.
2. Field calibration For SLite10, SLite14(GI, GII), SLite14C,and SLite22 LED wall, if it is tile based un-uniform, use “modify AC” (Refers to chapter 2.5) to correct the tile’s un-uniform.
2. Field calibration 2.2 Start up Field Calibration How to start up Field Calibration While there are differences in uniformity for a LED screen, double click the field calibration icon on the desktop or select start- > program -> Barco FCS-100 -> FCS-100 to start up.
2. Field calibration 2.3 Configuration What is Configuration In tab “configuration”, configure the connect mode and LED type to establish connection with LED screen How to configure D-320/DMP-100 based digitizer 1. Select “RS232” when connecting with DB-320 or DMP-100 2. Press “open” button to set the communication parameters 3.
2. Field calibration (1) (2) (3) Image 2-7 configure DX-700 How to select LED type Select LED type from the drop down list Image 2-8 select led type FCS-100 software supports following LED types: SLite10, SLite14 (GI, GII), SLite14C, Slite22, SLite10XP/FX, TF20, DB-X20 and TF-16. Make sure the right LED type is selected before establishing connection. How to establish connection If the connection is unsuccessful, “Not establish connection!” alarm is shown.
2. Field calibration 2.4 Display control Digital contrast To change the brightness, click on the slider and move it left or right until the desired value is reached. At right of the slider shows the current brightness (percent of the maximal brightness) Image 2-9 Digital contrast Digital contrast is in broadcast mode to change the brightness of all tiles. Advanced Advanced has Patterns switch, OSD display, Enable Calibration and Disable Calibration functions as below illustrated.
2. Field calibration • Patterns Press “Patterns” button. In the popup dialog, check the check box “show internal pattern” or uncheck it to get the internal or external pattern. If it’s internal pattern, single color can be selected by checking the check box “Red”, “Green”, or “Blue” in “Pattern Color”. Or, Loop RGBW to get the White, Red, Green and Blue color loop automatically 1 2 Image 2-10 • OSD Press “OSD” button. In the popup dialog, click at the right of the list, select the desired info.
2. Field calibration • Enable Calibration Press “Enable Calibration” to load the calibration as illustrated. Image 2-12 Enable calibration • Disable Calibration Press “Disable Calibration” to cancel the calibration as illustrated. Image 2-13 Disable Calibration To show the OSD info, “Enable OSD” must be checked.
2. Field calibration 2.5 Modify AC What is modify AC For SLite10, SLite14(GI, GII), SLite14C,and SLite22 LED wall, AC value can be modified to adjust the uniformity by tile. How to modify AC 1. input the desired tile address in text. 2. press “Read AC” to obtain the current AC value. It will be shown in texts “Red”,” Green”, and” Blue”. 3. Input new AC value in text if necessary, and press “Write AC” to make it works.
2. Field calibration 2.6 Field adjust Why do Field adjust To correct the uniformity of LED wall, a new LMT brightness value of the selected frame needs to be set to calibrate it. WARNING: Due to the possibility of making some error in modifying LMT data, So, Must back up the raw LMT data on controller PC before modifying it Backup/Restore LMT Data 1. To backup or restore LMT Data, press “Backup/Restore LMT Data” In the pop up dialog 2.
2. Field calibration (1) (2) Image 2-16 Show frame position information 3. And on the LED wall, this selected frame is also outline colored Image 2-17 Show frame position on LED screen Use “Select Frame” to make sure the desired frame is selected before modifying it. LMT Data ”LMT Data” shows the LMT brightness Y and color coordinates x, y of the selected frame.
2. Field calibration Image 2-18 Modify and simulate Do “Simulate” with the new LMT data before “Modify” it, is recommended Targets Press “View Targets”, to view the calibration target in the pop up dialog as illustrated. Image 2-19 View Targets View log file View log file records the log of current day. Press “View log file”, view log in the pop up dialog as illustrated.
2.
A. Wireless A. WIRELESS Overview Wireless is an optional module to connect CSE’s PC with controller PC via wireless network to get convenience for on-site operation. Following is three suppliers of wireless device. And the first one Axelwave is recommended Image A-1 Wireless solution Items / Suppliers Axelwave cisco NetGear AP Product Picture AP Size Max Output Power Signal Transmisson distance˄open country˅ 25.6cm X 19.6cm X 6.4cm 20.3 cm x 20.57 cm x 7.87 cm 26.5cm X 26.5cm X 5.
A.
A. Wireless A.1 Software Installation Software Installation After the physical connection, Access Point software need to be installed, and the wireless network card driver is optional, which depends on CSE’s PC. Overview AP (Access Point) should be fastened to or placed the visible location in order to the transmission of wireless signal. The front panel of Access Point should face the direction of the receiver (eg:a notebook etc).
A. Wireless Image A-6 4. Click on the “Install” button to the process of installation The performance of program needs the WinPcap software package. Install this software Image A-7 5.
A. Wireless Image A-8 6. Finish the whole installation of software Image A-9 7. After finishing the installation of Wireless LAN Management System.it will be added into Start Menu of windows desktop. 8. Open Start Menu and select Wireless LAN Management System; input the password to log on. Image A-10 9. Initial account password:admin 10.
A. Wireless Image A-11 11. Open the menu of “System”, click “search” to perform automatic IP search Image A-12 12.
A. Wireless Image A-13 13.Finish the search, you can find the list of devices detected Image A-14 14.
A. Wireless Image A-15 Wireless Network Card Installation Preparations First assemble the wireless network card with the following items • High-Power Wireless USB Adapter • One USB Cable • One 2dBi antenna Then you can insert the USB port of Notebook to use it. Driver installation Before using wireless network card, you should firstly install the driver, configure wireless network card and make it in the same network segment with AP.
A. Wireless Image A-16 2. The welcome window pops up. Click on the “Next” button to proceed Image A-17 3. Please wait while installation Image A-18 4. This Windows Logo testing warning window may pop up upon installation.
A. Wireless Image A-19 5. If you are using Windows 98se or ME, the system may ask for the driver CD.Please click the Browse button. Select your CD-ROM Drive then select USB Driver Win98 (or WINME) to browse the driver. If not, please skip this step. 6. Click on the “Finish” button to complete driver and utility installation. Image A-20 7. For Windows XP and 2000 users, please insert this USB wireless adapter to your computer.
A. Wireless Image A-21 10.Select “Install the software automatically” and then click the “Next” button. Image A-22 11. Please wait while installing the driver. The Windows logo testing warning window may pops up again. Please click on the “Continue Anyway” button to continue.
A. Wireless Image A-23 12.Click on the “Finish” button to complete installation.