Data Sheet Cisco MDS 9000 Family Pluggable Transceivers Product Overview ® The Cisco Small Form-Factor Pluggable (SFP), Enhanced Small Form-Factor Pluggable (SFP+), and X2 devices for use on the Cisco MDS 9000 family of products are hot-swappable transceivers that plug into ports on the Cisco MDS 9000 family director switching modules and fabric switches. These transceivers give users the flexibility to choose different cabling types and distances on a port-by-port basis.
Data Sheet Switching Module and Fabric Switch DS-X2-FC10GCX4=C DS-X2E10G-SR=A DS-CWDMxxxx= DSCWDM4Gxxxx=A DWDM-SFPxxxx=A DS-X9016 Yes Yes DS-X9032 Yes Yes DS-X9032-SSM Yes DS-X9112 Yes ONS-SC-4Gxx.
Data Sheet Figure 1. Cisco 2-Gbps Fibre Channel SFPs Technical Specifications Connectors and Cabling ● Connectors: Dual LC connector Table 2 summarizes the cabling specifications. Table 2. Cisco 2-Gbps Fibre Channel SFP Cabling Specifications SFP Wavelength (nanometers) Fiber Type Core Size (microns) Baud Rate (Gigabaud [GBd]) Cable Distance DS-SFP-FC-2G-SW 850 MMF 62.5 1.0625 300 m (984 ft) 62.5 2.125 150 m (492 ft) DS-SFP-FC-2G-LW 1310 SMF 50.0 (Optical Multimode 2 [OM2]) 1.
Data Sheet Regulatory and Standards Compliance ● Compliant with Fibre Channel FC-PI 200-SM-LC-L, FC-PI 200-M5-SN-I, and 200-M6-SN-I 2.125 GBd specifications ● Compliant with Fibre Channel FC-PI 100-SM-LC-L, FC-PI 100-M5-SN-I, and FC-PI 100-M6-SN-I; and FC-PH2 100-SM-LC-L, FC-PH2 100-M5-SN-I, and FC-PH2 100-M6-SN-I 1.0625 GBd specifications ● Laser Class I 21CFR1040 Ordering Information Table 5 provides ordering information. Table 5.
Data Sheet Table 6. Cisco 4-Gbps Fibre Channel SFP Cabling Specifications SFP Wavelength (nanometers) Fiber Type Core Size (microns) Baud Rate (GBd) DS-SFP-FC4G-SW 850 MMF 62.5 1.0625 300 m (984 ft) 62.5 2.125 150 m (492 ft) 62.5 4.250 70 m (230 ft) 50.0 (OM2) 1.0625 500 m (1640 ft) 50.0 (OM2) 2.125 300 m (984 ft) 50.0 (OM2) 4.250 150 m (492 ft) 50.0 (OM3) 1.0625 860 m (2821 ft) 50.0 (OM3) 2.
Data Sheet ● Compliant with Fibre Channel FC-PI 100-SM-LC-L, FC-PI 100-M5-SN-I, and FC-PI 100-M6-SN-I; and FC-PH2 100-SM-LC-L, FC-PH2 100-M5-SN-I, and FC-PH2 100-M6-SN-I 1.0625 GBd specifications ● Laser Class I 21CFR1040 Ordering Information Table 9 provides ordering information. Table 9.
Data Sheet DS-SFP-FC8G-LW 1310 SMF 50.0 (OM2) 8.500 50 m (164 ft) 50.0 (OM3) 2.125 500 m (1640 ft) 50.0 (OM3) 4.250 380 m (1246 ft) 50.0 (OM3) 8.500 150 m (492 ft) 50.0 (OM4) 2.125 520 m (1706 ft) 50.0 (OM4) 4.250 400 m (1312 ft) 50.0 (OM4) 8.500 190 m (623 ft) 9.0 2.125 10 km (6.2 mi) 9.0 4.250 10 km (6.2 mi) 9.0 8.500 10 km (6.2 mi) The minimum cable distance for all SFP+ listed (MMF and SMF) is 6.5 feet (2 meters). Note: Dimensions ● Dimensions (H x W x D): 8.5 x 13.
Data Sheet Ordering Information Table 13 provides ordering information. Table 13.
Data Sheet Dimensions ● Dimensions (H x W x D): 8.5 x 13.75 x 55.2 mm Environmental Conditions and Power Requirements Table 15 presents the optical parameters, and Table 16 presents the temperature ranges. Table 15. Optical Parameters SFP Average Transmit Power (dBm) Average Receive Power (dBm) Fiber Loss Budget (dBm) Max Min Max Min DS-SFP-FCGE-SW –1.2 –10.0 (FC) and – 9.5 (GE) 0 –17 (GE) ● 2.1 (FC: 62.5 microns) and 2.62 (FC: 50.0 microns [OM2]) ● 2.38 (GE: 62.5 microns) and 3.
Data Sheet Cisco Copper Gigabit Ethernet SFPs To enable even more cabling flexibility, the Cisco MDS 9000 family offers a copper Gigabit Ethernet SFP. Based on the 1000BASE-T standard, the Cisco Copper Gigabit Ethernet SFP (Figure 5) provides cost-effective connectivity for data center applications. The Cisco Copper Gigabit Ethernet SFP (part number DS-SFP-GE-T) allows a user to use standard Category-5 unshielded twisted pair (UTP) cabling for Ethernet connectivity. Figure 5.
Data Sheet Cisco 10-Gbps Fibre Channel X2 Transceivers The Cisco Fibre Channel X2 transceivers are designed to provide high-performance Fibre Channel connectivity for the 10-Gbps Fibre Channel ports on the Cisco MDS 9000 family platform.
Data Sheet Table 21. X2 Port Cabling Specifications X2 Wavelength (nanometers) Fiber Type Core Size (microns) Baud Rate (GBd) Cable Distance DS-X2-FC10G-SR 850 MMF 62.5 10.51875 33 m (108 ft) 50.0 (OM3) 10.51875 300 m (984 ft) 10.51875 10 km (6.2 mi) DS-X2-FC10G-LR 1310 SMF 9.0 DS-X2-FC10G-ER 1550 SMF 9.0 10.51875 40 km (24.8 mi) DS-X2-FC10G-CX4 – Copper – 10.51875 15 m (49.2 ft) The minimum cable distance for all listed transceivers (MMF and SMF) except CX4 is 6.
Data Sheet DS-X2-FC10G-LR= 10-Gbps Fibre Channel-Long-reach, X2, SC, Spare DS-X2-FC10G-ER 10-Gbps Fibre Channel-Extended-reach, X2, SC DS-X2-FC10G-ER= 10-Gbps Fibre Channel-Extended-reach, X2, SC, Spare DS-X2-FC10G-CX4 10-Gbps Fibre Channel-Copper Transceiver, X2, CX4 DS-X2-FC10G-CX4= 10-Gbps Fibre Channel-Copper Transceiver, X2, CX4, Spare DS-CAB-15M= 15m Cable for 10G Copper X2 transceiver, spare DS-CAB-1M= 1m Cable for 10G Copper X2 transceiver, spare Cisco 10-Gbps Ethernet X2 Transceivers
Data Sheet Environmental Conditions and Power Requirements Table 26 presents the optical parameters, and Table 27 presents the temperature ranges. Table 26. Optical Parameters X2 Average Transmit Power (dBm) Max Min Max Min DS-X2-E10G-SR –1.2 –7.3 –1.0 –9.9 Table 27. Average Receive Power (dBm) Fiber Loss Budget 2.6 (50.
Data Sheet Figure 10 shows a common point-to-point deployment scenario for the Cisco MDS 9000 family using the Cisco CWDM SFP solution. Two endpoints are directly connected through a fiber link. The Cisco CWDM SFP solution enables customers to add or drop up to eight channels onto a pair of single-mode fiber strands. As a result, the need for additional fiber is reduced.
Data Sheet Parameter Symbol Minimum Typical Maximum Units Notes and Conditions Dispersion penalty at 100 km (62.1 mi) – – – 2 dB At 1.25 Gbps Note: ● Parameters are specified over temperature and at end of life unless otherwise noted. ● When shorter distances of single-mode fiber are used, you may need to insert an inline optical attenuator in the link to avoid overloading the receiver. Table 30.
Data Sheet Table 32. Optical Parameters for Cisco 4-Gbps CWDM SFPs Parameter Symbol Minimum Typical Maximum Units Notes and Conditions Transmitter center wavelength lambda_c (x–6) x (x+6) nm Available center wavelengths are 1470, 1490, 1510, 1530, 1550, 1570, 1590, and 1610 nm Side-mode suppression ratio SMSR 30 – – dB – Transmitter optical output power Pout 1.0 – 5.
Data Sheet Part Number Description Color DS-CWDM4G1590= 1590 nm CWDM 1/2/4-Gbps Fibre Channel SFP Red DS-CWDM4G1610= 1610 nm CWDM 1/2/4-Gbps Fibre Channel SFP Brown Cisco CWDM OADMs Technical Specifications for Cisco CWDM OADMs The Cisco CWDM OADMs are passive devices that provide the capability to multiplex and demultiplex, or add and drop wavelengths from multiple fibers onto one fiber. The OADM connectors are interfaced with color-matching Cisco CWDM SFPs on the equipment side.
Data Sheet Regulatory and Standards Compliance ● Network Equipment Building Standards (NEBS) Level 3 Warranty ● Standard warranty: One year Ordering Information Table 37 provides ordering information. Table 37.
Data Sheet Part Number Description DWDM-SFP-5012= Cisco 1550.12 NM DWDM Gigabit Ethernet and 1/2-Gbps Fibre Channel SFP, spare DWDM-SFP-4851= Cisco 1548.51 NM DWDM Gigabit Ethernet and 1/2-Gbps Fibre Channel SFP, spare DWDM-SFP-4772= Cisco 1547.72 NM DWDM Gigabit Ethernet and 1/2-Gbps Fibre Channel SFP, spare DWDM-SFP-4692= Cisco 1546.92 NM DWDM Gigabit Ethernet and 1/2-Gbps Fibre Channel SFP, spare DWDM-SFP-4612= Cisco 1546.
Data Sheet PID Description ONS-SC-4G-54.9= SFP – 4G FC 1554.94, 100 GHz, LC ONS-SC-4G-55.7= SFP – 4G FC 1555.75, 100 GHz, LC ONS-SC-4G-56.5= SFP – 4G FC 1556.55, 100 GHz, LC ONS-SC-4G-58.1= SFP – 4G FC 1558.17, 100 GHz, LC ONS-SC-4G-58.9= SFP – 4G FC 1558.98, 100 GHz, LC ONS-SC-4G-59.7= SFP – 4G FC 1559.79, 100 GHz, LC ONS-SC-4G-60.6= SFP – 4G FC 1560.61, 100 GHz, LC Table 40. Cisco 4-Gbps DWDM SFP Transceiver Ordering Information – Other Wavelengths PID Description ONS-SC-4G-30.
Data Sheet Cisco 10-Gbps Ethernet DWDM X2 Transceiver The Cisco 10-Gbps Ethernet DWDM X2 Transceiver pluggable module (part number DWDM-X2-xx.xx=) enables high-performance Fibre Channel connectivity for the Cisco MDS 9000 family 10-Gbps Fibre Channel switching module to an existing Ethernet DWDM infrastructure. The data format transmitted by the Ethernet DWDM X2 transceiver (DWDM-X2-xx.
Data Sheet Part Number Description ITU Channel DWDM-X2-35.82= 10GBASE-DWDM 1535.82 nm X2 (100-GHz ITU grid) 52 DWDM-X2-35.04= 10GBASE-DWDM 1535.04 nm X2 (100-GHz ITU grid) 53 DWDM-X2-34.25= 10GBASE-DWDM 1534.25 nm X2 (100-GHz ITU grid) 54 DWDM-X2-32.68= 10GBASE-DWDM 1532.68 nm X2 (100-GHz ITU grid) 56 DWDM-X2-31.90= 10GBASE-DWDM 1531.90 nm X2 (100-GHz ITU grid) 57 DWDM-X2-31.12= 10GBASE-DWDM 1531.12 nm X2 (100-GHz ITU grid) 58 DWDM-X2-30.33= 10GBASE-DWDM 1530.