Spec Sheet Cisco UCS C24 M3 High-Density Large Form Factor Rack-Mount Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV B.
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . .
OVERVIEW OVERVIEW The Cisco® UCS C24 M3 Rack Server combines economics and a density-optimized feature set from entry level enterprise to SMB with applications such as scale out, virtualization, IT and web infrastructure, VPN servers, file/print servers, and appliances.
DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C24 M3 High-Density LFF Rack Server. Figure 2 Chassis Front View 4 5 6 1 HDD01 HDD02 HDD03 HDD04 HDD05 HDD06 HDD07 HDD08 HDD09 HDD10 HDD11 HDD12 285249 2 3 1 USB 2.
DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel.
BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 8.
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Video Description The Emulex Pilot 3 Integrated Baseboard Management Controller provides video: ■ Matrox G200e video controller ■ Integrated 2D graphics core with hardware acceleration ■ Interfaces Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz ■ 24-bit color depth for all resolutions less than 1600x1200 ■ 8 MB video memory ■ Rear panel • One DB9 serial port connector • Four USB 2.
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C24 M3 High-Density LFF Rack Server: 8 ■ STEP 1 VERIFY SERVER SKU, page 9 ■ STEP 2 SELECT CPU(s), page 10 ■ STEP 3 SELECT MEMORY, page 12 ■ STEP 4 SELECT RAID CONFIGURATION, page 16 ■ STEP 5 SELECT HARD DISK DRIVES (HDDs), page 20 ■ STEP 6 SELECT PCIe OPTION CARD(s), page 22 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 23 ■ STEP 8 SELECT AC POWER CORD(s), page 28 ■ STEP 9 ORDER POWER SUP
CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU The 12-drive version of the server has a SAS expander enabled backplane that supports up to 12 hard disk drives with a single RAID card. Verify the product ID (PID) of the server as shown in Table 2.
CONFIGURING the SERVER STEP 2 SELECT CPU(s) The standard CPU features are: ■ Intel Xeon E5-2400 v2 or E5-2400 series processor family CPUs ■ Intel C600 chipset ■ Cache size of up to 25 MB Select CPUs The available CPUs are listed in Table 3. Table 3 Available Intel CPUs: Xeon E5-24xx Series Intel Number Product ID (PID) Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI (GT/s) Highest DDR3 DIMM Clock Support (MHz)1 Intel Xeon E5-2400 v2 UCS-CPU-E52470B E52470 v2 2.4 95 25 10 8.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU configurations: ■ Select any one CPU listed in Table 3. (2) 2-CPU Configurations: ■ Select two identical CPUs from any one of the rows of Table 3. Caveats ■ Select one or two identical CPUs. ■ If you select one CPU, only PCIe slots 1 and 2 are available for use. ■ For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 10).
CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are: ■ ■ Figure 4 12 DIMMs — Clock speed: 1600 or 1333 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: 1.5 V or 1.35 V — Registered ECC DDR3 DIMMS (RDIMMS), unregistered DIMMs (UDIMMs), and load-reduced DIMMs (LRDIMMs) Memory is organized with three memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 4.
CONFIGURING the SERVER Select DIMMs Select the memory configuration. The available memory DIMMs are listed in Table 4. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel.
CONFIGURING the SERVER (2) 1-CPU configuration with memory mirroring: Select 2 or 4 DIMMs. The DIMMs will be placed by the factory as shown in the following table: ■ Number of DIMMs (Channel A is not used with memory mirroring) DIMM Placement 2 CPU 1: 1 DIMM in Channel B, 1 DIMM in Channel C 4 CPU 1: 2 DIMMs in Channel B, 2 DIMMs in Channel C (3) 2-CPU configuration without memory mirroring: Select from 1 to 6 DIMMs per CPU (2 to 12 DIMMs total).
CONFIGURING the SERVER ■ By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM (service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields 1600-MHz speeds, provided: — The DIMMs are 1600-MHz devices — The CPUs chosen support 1600-MHz operation.
CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE: When creating a RAID volume, follow these guidelines: ■ Use the same capacity for each drive in the volume ■ Use either all SAS drives or all SATA drives ■ Use either all HDDs or all SSDs NOTE: The number of RAID groups (virtual drives) supported per controller is as follows: ■ LSI MegaRAID SAS 9270CV-8i RAID controller card = 64 ■ LSI MegaRAID 9240-8i RAID controller card = 16 ■ LSI MegaRAID 9220-8i RAID controller card = 16 (1) O
CONFIGURING the SERVER Table 5 Available PCIe RAID Controller Options (continued) Product ID (PID) PID Description UCS-RAID9270CV-8i LSI MegaRAID 9270CV-8i (with supercap power backup) ■ Supports up to 12 internal SAS+SATA drives.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU Configurations Select a PCIe RAID controller from Table 5 on page 16. You may also select an appropriate optional RAID configuration listed in Table 5 on page 16. NOTE: In 1-CPU configurations, PCIe slot 2 is the default slot supported for an internal drive RAID controller. PCIe slots 3, 4, and 5 are not supported for 1-CPU systems.
CONFIGURING the SERVER the controller selected. RAID levels 50 and 60 are supported, depending on the RAID controller selected, although they are not available as configuration options ■ Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the 3/4-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards. ■ You can choose one PCIe RAID controller.
CONFIGURING the SERVER STEP 5 SELECT HARD DISK DRIVES (HDDs) The standard disk drive features are: ■ 3.5-inch large form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Table 6. Table 6 Available Hot-Pluggable Sled-Mounted HDDs PID Description Drive Type Capacity UCS-HD4T7KS3-E 4TB SAS 7.2K RPM 3.5 inch HDD SAS 4 TB UCS-HDD3TI2F214 3TB SAS 7.2K RPM 3.5 inch HDD SAS 3 TB UCS-HDD2TI2F213 2TB SAS 7.2K RPM 3.
CONFIGURING the SERVER Approved Configurations (1) LSI MegaRAID 9270CV-8i (with data cache and supercap), LSI MegaRAID 9240-8i, or LSI MegaRAID 9220-8i ■ For the 12-drive backplane with expander option, select up to 12 drives listed in Table 6 on page 20. Caveats ■ You can mix SATA and SAS drives. ■ If you select one or more HDDs, you must select a PCIe RAID controller.
CONFIGURING the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCIe card offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Select PCIe Option Cards The available PCIe option cards are listed in Table 7.
CONFIGURING the SERVER ■ If you did not choose a PCIe RAID controller, from Table 7 you can select up to two PCIe option cards for 1-CPU systems and up to five PCIe option cards for 2-CPU systems. (2) One PCIe RAID controller ■ If you selected a PCIe RAID controller, you can select additional PCIe option cards listed in Table 7 until all of the slots are filled, if desired. The PCIe cards plug into riser 1 and riser 2. NOTE: RAID controllers are always installed in half-height slots.
CONFIGURING the SERVER Choose Optional Twinax Cables Table 8 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.
CONFIGURING the SERVER redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available. See the Figure 5 on page 27 for typical SFP+ and twinax connections to the network cards. Caveats Check the table on the following page for compatibility between the PCIe network cards and SFPs or twinax cables. NOTE: The table shows all PCIe network cards for all C-series servers. Not all of the cards shown in the table are supported in this server.
CONFIGURING the SERVER Table 10 PCIe Card Compatibility Cisco SFP Modules Twinax Cables SFP-10G-SR DS-SFP-FC8G-SW PCIe Cards Converged Network Adapters (CNAs) UCSC-PCIE-BSFP (Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI) UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) UCSC-PCIE-C10T-02 (Cisco VIC 1225T Dual Port 10GBaseT CNA) UCSC-PCIE-C40Q-02 (Cisco VIC 1285 Dual Port 40Gb QSFP CNA) UCSC-PCIE-C40Q-03 (Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA) UCSC-PCIE-ESFP (Emulex OCe11102-FX dual-port
CONFIGURING the SERVER Table 10 PCIe Card Compatibility (continued) Cisco SFP Modules Twinax Cables SFP-10G-SR DS-SFP-FC8G-SW PCIe Cards N2XX-AQPCI05 (QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA) UCSC-PCIE-Q2672 (Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics) UCSC-PCIE-E16002 (Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics) No Preinstalled - do not change SFP No Preinstalled - do not change SFP No Preinstalled - do not change SFP Notes . . . 1.
CONFIGURING the SERVER STEP 8 SELECT AC POWER CORD(s) Using Table 11, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
CONFIGURING the SERVER Table 11 Available Power Cords Product ID (PID) PID Description CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug, Australia Images Connector: EL 701C (EN 60320/C15) Plug: EL 210 (BS 1363A) 13 AMP fuse Power Cord, SFS, 250V, 10A, China Cordset rating 10A, 250V (2500 mm) Connector: EL 701 (IEC60320/C13) CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7 Plug, EU Plug: M2511 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.
CONFIGURING the SERVER Table 11 Available Power Cords Product ID (PID) PID Description CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Images Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.
CONFIGURING the SERVER STEP 9 ORDER POWER SUPPLIES The C24 M3 server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply. A fully loaded server might need to be powered with two 450 W or two 650 W power supplies (see Table 12). Prior to making a power supply selection, the UCS Power Calculator should be run to determine the right size power supply for your server configuration.
CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 13 to order a cable management arm. Table 13 Cable Management Arm Product ID (PID) PID Description UCSC-CMA1 Cable Management Arm for C24 rack servers NOTE: If you order and install a cable management arm, you will need the longest power cable available.
CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy.
CONFIGURING the SERVER STEP 12 ORDER OPTIONAL USB 2.0 DRIVES You may order one optional USB 2.0 drive. One socket on the motherboard can accommodate either the 8 GB drive or the 16 GB drive. The 8 or 16 GB drive (if ordered) is blank and comes installed on the motherboard. It can be used for a hypervisor or a license dongle. The USB drive ordering information is listed in Table 15. Table 15 USB 2.
CONFIGURING the SERVER STEP 13 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE Several operating systems and value-added software programs are available. Select as desired from Table 16.
CONFIGURING the SERVER Table 16 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) Red Hat Enterprise Linux RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required RHEL-2S-1G-3A RHEL/2 Socket/1 Guest/3Yr Svcs Required RHEL-2S-4G-1A RHEL/2 Socket/4 Guest/1Yr Svcs Required RHEL-2S-4G-3A RHEL/2 Socket/4 Guest/3Yr Svcs Required RHEL-2S-UG-1A RHEL/2 Socket/U Guest/1Yr Svcs Required RHEL-2S-UG-3A RHEL/2 Socket/U Guest/3Yr Svcs Required RHEL-HA-2S-1A RHEL Op
CONFIGURING the SERVER Table 16 OSs and Value-Added Software (for 2-CPU servers) (continued) PID Description Product ID (PID) VMware 5 VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Proces
CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 17.
CONFIGURING the SERVER STEP 15 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media.
CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
CONFIGURING the SERVER See Table 20.
CONFIGURING the SERVER You can choose a service listed in Table 22.
CONFIGURING the SERVER Table 23 Drive Retention Service Options (continued) Service Description Service Program Name SMARTnet for UCS HW ONLY+Drive Retention UCS HW+DR Service Level GSP Service Level Product ID (PID) UCWD7 24x7x4 Onsite CON-UCWD7-C24M3L UCWD5 8x5xNBD Onsite CON-UCWD5-C24M3L For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.
OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C24 M3 LFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 24. Racks are shipped separately from the C24 M3 LFF server.
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC24 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 24). Table 25 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page 56.
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C24 M3 chassis with the top cover removed is shown in Figure 6. Figure 6 C24 M3 LFF With Top Cover Off 2 3 4 5 6 7 SYS FAN1 PCIe riser 1 8 CPU 1 SYS FAN2 9 Port 1 10 SYS FAN3 1 PCIe riser 2 CPU 2 Port 0 11 SYS FAN4 PSU 2 (top) 285245 PSU 1 (bottom) 12 13 1 Drives (hot-swappable, accessed through front panel) 8 Internal USB 2.
SUPPLEMENTAL MATERIAL 6 CPUs and heatsinks (up to two) 13 RAID backup unit mounting locations (two) 7 PCIe riser 1 (two full-height slots) - - CPUs and DIMMs Physical Layout Each CPU has three DIMM channels: ■ CPU1 has channels A, B, and C ■ CPU2 has channels D, E, and F Each DIMM channel has two banks: Bank 1 and Bank 2. The blue-colored DIMM banks are for Bank 1 and the black-colored are for Bank 2.
SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server, you should consider the following items: ■ ■ 48 Each channel has two DIMM slots (for example, channel A = slots A1 and A2). — Each channel can operate with one or two DIMMs installed. — If a channel has only one DIMM, populate slot 1 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically.
SUPPLEMENTAL MATERIAL Recommended Memory Population This section explains the recommended DIMM population order rules for the C24 M3 server. ■ All DIMMs must be DDR3 DIMMs. ■ Mixing of Registered and Unbuffered DIMMs is not allowed per platform. ■ Mixing of ECC and non-ECC DIMMs is not allowed per platform. ■ Do not mix 1333-MHz DIMMs with 1600-MHz DIMMs. Follow Table 26 when populating DIMMs in the server.
SUPPLEMENTAL MATERIAL Additional DIMM Populations The list in Table 27 is not a complete list of all supported DIMM populations, but highlights common configuration options.
SUPPLEMENTAL MATERIAL Low-Voltage DIMM Considerations The C24 M3 server can be ordered with low-voltage (1.35 V) DIMMs only. Note the following considerations: ■ Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size. ■ Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).
SUPPLEMENTAL MATERIAL RAID Summary The C24 M3 LFF server can be ordered with a 12-drive backplane with a SAS expander. ■ Drive support is as follows: — The LSI MegaRAID SAS 9270CV-8i, 9240-8i, and 9220-8i PCIe cards support up to 12 drives each See Table 28 for a summary of the supported RAID configuration options.
SUPPLEMENTAL MATERIAL RAID Option ROM (OPROM) Settings The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in Figure 8.
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 9) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 29. Table 29 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.
SUPPLEMENTAL MATERIAL Figure 9 Cisco R42610 Rack Front view - door closed Front view - door open Cisco UCS C24 M3 High-Density LFF Rack Server Front view - door removed 55
SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
SUPPLEMENTAL MATERIAL Motherboard USB Port The C24 M3 LFF motherboard has one general-purpose USB socket as shown in Figure 11. Figure 11 Motherboard USB Port SYS FAN1 PCIe riser 1 1 CPU 1 SYS FAN2 Port 1 SYS FAN3 PCIe riser 2 CPU 2 Port 0 SYS FAN4 PSU 1 (bottom) 285245 PSU 2 (top) 1 USB 2.
SUPPLEMENTAL MATERIAL LED Indicators The server contains LED indicators on the front and rear panels. Their functions are described in the following sections. Front Panel Figure 12 shows the front panel LEDs.
SUPPLEMENTAL MATERIAL Table 30 Front Panel LEDs (continued) LED Hard Drive Activity Network Link Status Temperature Status Fan Status LED State Meaning Blinking (amber) The hard drive is rebuilding Off There is no hard drive in the hard drive sled (no access, no fault) On (green) The hard drive is ready Blinking (green) The hard drive is reading or writing data Off Undefined On (green) Link pulses detected on any of the LOM ports, but no activity.
SUPPLEMENTAL MATERIAL Table 30 Front Panel LEDs (continued) LED LED State Meaning System Status Off Undefined On (green) Server is in normal operating condition On (amber) Server is in a degraded operational state. For example: Blinking (amber) ■ Power supply redundancy is lost. ■ CPUs are mismatched. ■ At least one CPU is faulty. ■ At least one DIMM is faulty. ■ At least one drive in a RAID configuration failed. Server is in a critical fault state. For example: ■ Boot failed.
SUPPLEMENTAL MATERIAL 1 Power supply fault LED 5 10/100/1000 Ethernet dedicated management link status LED 2 Power supply AC OK LED 6 10/100/1000 Ethernet dedicated management link speed LED 3 1-GbE link speed LED 7 Identification button/LED 4 1-GbE link status LED - - See Table 31 for the functions of the rear panel LEDs.
SUPPLEMENTAL MATERIAL Table 31 Rear Panel LEDs (continued) LED LED State Meaning Unit ID (LED is integrated into unit ID button) Off Unit ID not active On (blue) Unit ID is activated 62 Cisco UCS C24 M3 High-Density LFF Rack Server
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 32 UCS C24 M3 Dimensions and Weight Parameter Value Height 3.45 in (87.6 mm) Width 16.93 in.(430 mm) Depth 26.0 in. (660.5 mm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 9 in. (233 mm) Weight Maximum (12 HDDs, 2 CPUs, 12 DIMMs, 2 power supplies) 53 lb (23.6 kg) Bare (0 HDD, 0 CPU, 0 DIMM, no power supply) 34.5 lbs (15.
TECHNICAL SPECIFICATIONS NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. The general power specifications for the C24 M3 LFF server 650 W power supply are listed in Table 33. Table 34 UCS C24 M3 LFF 650 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self-ranging, 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal) Maximum AC input current 7.6 A maximum at 100 VAC 3.
TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C24 M3 server are listed in Table 35. Table 35 UCS C24 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 95° F (5 to 35° C) Maximum temperature is to be derated by 1 degree C for every 305 m (1000 ft.) of altitude above sea level Temperature nonoperating –40 to 149°F (–40 to 65°C) Humidity (RH) nonoperating, non-condensing 10 to 90% Altitude operating 0 to 3,000 m (0 to 10,000 ft.
TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Table 36. Table 36 UCS C-Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC Safety UL 60950-1 Second Edition CAN/CSA-C22.2 No.