Dimensions and Weight
Power Specifications
The general power specifications for the C24 M3 LFF server 450 W power supply are listed in Table 33.
Table 32 UCS C24 M3 Dimensions and Weight
Parameter Value
Height 3.45 in (87.6 mm)
Width 16.93 in.(430 mm)
Depth 26.0 in. (660.5 mm)
Front Clearance 3 in. (76 mm)
Side Clearance 1 in. (25 mm)
Rear Clearance 9 in. (233 mm)
Weight
Maximum (12 HDDs, 2 CPUs, 12 DIMMs, 2 power supplies) 53 lb (23.6 kg)
Bare (0 HDD, 0 CPU, 0 DIMM, no power supply) 34.5 lbs (15.65 kg)
Table 33 UCS C24 M3 LFF 450 W Power Supply Specifications
Description Specification
AC input voltage 90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
Maximum AC input current 6 A maximum at 100 VAC
3 A maximum at 208 VAC
Maximum AC inrush current 9 A peak @ 35° C, 208 VAC
Maximum output power for the
power supply
450 W
Power supply output voltage Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency CSCI Platinum