Datasheet

Cisco UCS C24 M3 High-Density LFF Rack Server
TECHNICAL SPECIFICATIONS
65
Environmental Specifications
The power specifications for the C24 M3 server are listed in Table 35.
Table 35 UCS C24 M3 Environmental Specifications
Parameter Minimum
Temperature operating 41 to 95° F (5 to 35° C) Maximum temperature is to be derated
by 1 degree C for every 305 m (1000 ft.) of altitude above sea
level
Temperature nonoperating –40 to 149°F (–40 to 65°C)
Humidity (RH) nonoperating,
non-condensing
10 to 90%
Altitude operating 0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)
5.9
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
46