Installation Guide

Table Of Contents
Step 3 Detach the power supply module as follows:
On the front of CGP-OLT-8T, use the Phillips head screwdriver and loosen the captive installation screw
on the power supply module.
On the rear of CGP-OLT-16T, use the Phillips head screwdriver and loosen the two captive installation
screws on the power supply module.
Step 4 Grasp the power supply module handle and slide the power supply module half out of the bay. Gently move
it from side to side, if necessary, to unseat it from the OLT.
Step 5 Place your other hand underneath to support the bottom of the power supply module and then remove the
module completely.
Figure 24: Removing the Power Supply Module from CGP-OLT-8T
Cisco Catalyst PON Series Switches Hardware Installation Guide
51
Removing and Replacing Field-Replaceable Units (FRUs)
Removing a Power Supply Module from an OLT
REVIEW DRAFT - CISCO CONFIDENTIAL